Near-Infrared Optical Imaging of Protease Activity for Tumor Detection
Abstract
PURPOSE: To build and test an optical imaging system that is sensitive to near-infrared fluorescent molecular probes activated by specific enzymes in tumor tissues in mice. MATERIALS AND METHODS: The imaging system consisted of a source that delivered 610-650-nm excitation light within a lighttight chamber, a 700-nm longpass filter for selecting near-infrared fluorescence emission photons from tissues, and a charge-coupled device (CCD) for recording images. The molecular probe was a biocompatible autoquenched near-infrared fluorescent compound that was activated by tumor-associated proteases for cathepsins B and H. Imaging experiments were performed 0-72 hours after intravenous injection of the probe in nude mice that bore human breast carcinoma (BT-20). RESULTS: The imaging system had a maximal spatial resolution of 60 microns, with a field of view of 14 cm2. The detection threshold of the nonquenched near-infrared fluorescent dye was subpicomolar in the imaging phantom experiments. In tissue, 250 pmol of fluorochrome was easily detected during the 10-second image acquisition. After intravenous injection of the probe into the tumor-bearing animals, tumors as small as 1 mm became detectable because of tumor-associated enzymatic activation of the quenched compound. CONCLUSION: Tumor proteases can be used as molecular targets, allowing visualization of millimeter-sized tumors. The development of this technology, probe design, and optical imaging systems hold promise for molecular imaging, cancer detection, and evaluation of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Self-citationIn vivo molecular target assessment of matrix metalloproteinase inhibition
Bremer, C., Tung, C.-H., & Weissleder, R. (2001) · Nature Medicine · doi:10.1038/89126 · Cited by 726
Self-citationWhole-body three-dimensional optoacoustic tomography system for small animals
Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3259361 · Cited by 304
Molecular Theranostics: A Primer for the Imaging Professional
Lee, D. Y., & Li, K. C. P. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.6797 · Cited by 95
Lamfers, M. L. M., Gianni, D., Tung, C.-H., Idema, S., Schagen, F. H. E., Carette, J. E., Quax, P. H. A., Van Beusechem, V. W., Vandertop, W. P., Dirven, C. M. F., et al. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-4264 · Cited by 52
Self-citation
Metadata
- Authors
- Mahmood, U., Tung, C.-H., Bogdanov, A., & Weissleder, R.
- Venue
- Radiology
- Published
- 1999-12
- Volume
- 213
- Issue
- 3
- Pages
- 866-870
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2050014887
- Cited by
- 301
- References
- 0
- FWCI
- 14.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Near-Infrared Optical Imaging of Protease Activity for Tumor Detection. https://app.cochat.ai/papers/10.1148/radiology.213.3.r99dc14866
- The paper
- Mahmood, U., Tung, C.-H., Bogdanov, A., & Weissleder, R. (1999). Near-Infrared Optical Imaging of Protease Activity for Tumor Detection. Radiology. https://doi.org/10.1148/radiology.213.3.r99dc14866
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.