The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Whole-body three-dimensional optoacoustic tomography system for small animals
Open accessAbstract
We develop a system for three-dimensional whole-body optoacoustic tomography of small animals for applications in preclinical research. The tomographic images are obtained while the objects of study (phantoms or mice) are rotated within a sphere outlined by a concave arc-shaped array of 64 piezocomposite transducers. Two pulsed lasers operating in the near-IR spectral range (755 and 1064 nm) with an average pulsed energy of about 100 mJ, a repetition rate of 10 Hz, and a pulse duration of 15 to 75 ns are used as optical illumination sources. During the scan, the mouse is illuminated orthogonally to the array with two wide beams of light from a bifurcated fiber bundle. The system is capable of generating images of individual organs and blood vessels through the entire body of a mouse with spatial resolution of approximately 0.5 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ntziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982
Wang, X., Xie, X., Ku, G., Wang, L. V., & Stoica, G. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2192804 · Cited by 505
Laser optoacoustic imaging system for detection of breast cancer
Ermilov, S. A., Khamapirad, T., Conjusteau, A., Leonard, M. H., Lacewell, R., Mehta, K., Miller, T., & Oraevsky, A. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3086616 · Cited by 493
Self-citationIn vivo dark-field reflection-mode photoacoustic microscopy
Maslov, K., Stoica, G., & Wang, L. V. (2005) · Optics Letters · doi:10.1364/ol.30.000625 · Cited by 413
Yang, X., Skrabalak, S. E., Li, Z.-Y., Xia, Y., & Wang, L. V. (2007) · Nano Letters · doi:10.1021/nl072349r · Cited by 407
High Sensitivity of In Vivo Detection of Gold Nanorods Using a Laser Optoacoustic Imaging System
Eghtedari, M., Oraevsky, A., Copland, J. A., Kotov, N. A., Conjusteau, A., & Motamedi, M. (2007) · Nano Letters · doi:10.1021/nl070557d · Cited by 374
Self-citationNear-Infrared Optical Imaging of Protease Activity for Tumor Detection
Mahmood, U., Tung, C.-H., Bogdanov, A., & Weissleder, R. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc14866 · Cited by 301
In vivo high-resolution 3D photoacoustic imaging of superficial vascular anatomy
Zhang, E. Z., Laufer, J. G., Pedley, R. B., & Beard, P. C. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/4/014 · Cited by 298
In vivo small-animal imaging using micro-CT and digital subtraction angiography
Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/19/r01 · Cited by 264
Imaging of tumor angiogenesis in rat brains in vivo by photoacoustic tomography
Ku, G., Wang, X., Xie, X., Stoica, G., & Wang, L. V. (2005) · Applied Optics · doi:10.1364/ao.44.000770 · Cited by 216
Cited by
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Yao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Volumetric real-time multispectral optoacoustic tomography of biomarkers
Razansky, D., Buehler, A., & Ntziachristos, V. (2011) · Nature Protocols · doi:10.1038/nprot.2011.351 · Cited by 309
Metadata
- Authors
- Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2009-11-01
- Volume
- 14
- Issue
- 06
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2138671144
- Cited by
- 304
- References
- 17
- FWCI
- 9.51
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Whole-body three-dimensional optoacoustic tomography system for small animals. https://app.cochat.ai/papers/10.1117/1.3259361
- The paper
- Brecht, H.-P. F., Su, R., Fronheiser, M. P., Ermilov, S. A., Conjusteau, A., & Oraevsky, A. A. (2009). Whole-body three-dimensional optoacoustic tomography system for small animals. Journal of Biomedical Optics. https://doi.org/10.1117/1.3259361
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.