Hepatic MR Imaging with a Dynamic Contrast-enhanced Isotropic Volumetric Interpolated Breath-hold Examination: Feasibility, Reproducibility, and Technical Quality
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the feasibility, reproducibility, and technical quality of a dynamic contrast material-enhanced isotropic three-dimensional (3D) volumetric interpolated breath-hold hepatic magnetic resonance (MR) imaging examination. MATERIALS AND METHODS: Fifty patients underwent 3D spoiled gradient-echo imaging (4.2/1.8 [repetition time msec/echo time msec]; flip angle, 12 degrees; interpolation in three directions; intermittent fat saturation; pixel size </= 2.5 mm in all dimensions) before and dynamically after administration of gadopentetate dimeglumine, with the first enhanced acquisition timed for hepatic arterial dominance by using a test bolus of contrast material. Qualitative and quantitative measures of image quality were determined. Patterns of arterial and venous anatomy were assessed. Ten patients (20%) underwent repeat imaging within 6 months, and reproducibility was evaluated. RESULTS: Hepatic contrast-to-noise ratios for nonenhanced and arterial, portal venous, and equilibrium phase studies averaged 13.0 +/- 12.6 (SD), 17.4 +/- 11.8, 30.4 +/- 16.2, and 28.6 +/- 21.1, respectively. During arterial phase, the liver enhanced a mean of 29% of the maximal enhancement as measured during portal venous phase. Hepatic vascular anatomic variants were comparable in distribution to those cited in published articles. Repeat studies were not significantly different in image quality when compared with original studies. CONCLUSION: High-quality arterial phase 3D volumetric interpolated breath-hold images can be obtained reliably and reproducibly when timed by using a test dose of contrast material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical anatomy and anatomical surgery of the liver
Bismuth, H. (1982) · World Journal of Surgery · doi:10.1007/bf01656368 · Cited by 791
Abdominal MR Imaging with a Volumetric Interpolated Breath-hold Examination
Rofsky, N. M., Lee, V. S., Laub, G., Pollack, M. A., Krinsky, G. A., Thomasson, D., Ambrosino, M. M., & Weinreb, J. C. (1999) · Radiology · doi:10.1148/radiology.212.3.r99se34876 · Cited by 538 · cited 2×
“Sequence details have been reported previously (13) and are summarized briefly as follows: symmetric echo (160 points)”
BackgroundSelf-citationYamashita, Y., Mitsuzaki, K., Yi, T., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M. (1996) · Radiology · doi:10.1148/radiology.200.1.8657948 · Cited by 272 · cited 1×
“I 110 (55) 30 (60) II 20 (10) 2 (4) III 22 (11) 3 (6) IV 2 (1) 1 (2) V 16 (8) 6 (12) VI 14 (7) 3 (6) VII 2 (1) 0 (0) VIII 4 (2) 1 (2) IX 9 (4.”
Du, Y. P., Parker, D. L., Davis, W. L., & Cao, G. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040517 · Cited by 216 · cited 1×
“With nearly isotropic 3D imaging, the pitfalls of intersection gaps and partial volume artifacts associated with 2D imaging can be avoided (27,28).”
BackgroundSegmented turboFLASH: method for breath-hold MR imaging of the liver with flexible contrast.
Edelman, R. R., Wallner, B., Singer, A., Atkinson, D. J., & Saini, S. (1990) · Radiology · doi:10.1148/radiology.177.2.2171014 · Cited by 142
Peterson, M. S., Baron, R. L., & Murakami, T. (1996) · Radiology · doi:10.1148/radiology.201.2.8888220 · Cited by 138 · cited 1×
“I 110 (55) 30 (60) II 20 (10) 2 (4) III 22 (11) 3 (6) IV 2 (1) 1 (2) V 16 (8) 6 (12) VI 14 (7) 3 (6) VII 2 (1) 0 (0) VIII 4 (2) 1 (2) IX 9 (4.”
Soyer, P. A., Bluemke, D. A., Choti, M. A., & Fishman, E. K. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.164.1.7998521 · Cited by 107 · cited 1×
“ously reported by using CT (18) and ultrasonographic (35) methods, and we attribute the difference to greater spatial”
MethodSegmental anatomy of the liver: poor correlation with CT.
Fasel, J. H. D., Selle, D., Evertsz, C. J. G., Terrier, F., Peitgen, H. O., & Gailloud, P. (1998) · Radiology · doi:10.1148/radiology.206.1.9423665 · Cited by 104
Kopka, L., Rodenwaldt, J., Vosshenrich, R., Fischer, U., Renner, B., Lorf, T., Graessner, J., Ringe, B., & Grabbe, E. (1999) · Radiology · doi:10.1148/radiology.211.1.r99mr2251 · Cited by 90 · cited 2×
“Using a 36-second MR sequence with similar effective pixel size and 0.15 mmol/kg gadopentetate dimeglumine, Kopka et al (31) recently demonstrated agreement between MR angiographic assessment and conventional angiographic assessment of hepatic arterial anatomy in 57 (95”
BackgroundInfluentialSoyer, P. A., Bluemke, D. A., Bliss, D., Woodhouse, C., & Fishman, E. K. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.1.8010258 · Cited by 64
Soyer, P. A., de Givry, S. C., Gueye, C., Lenormand, S., Somveille, E., & Scherrer, A. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.5.8615254 · Cited by 61 · cited 1×
“I 110 (55) 30 (60) II 20 (10) 2 (4) III 22 (11) 3 (6) IV 2 (1) 1 (2) V 16 (8) 6 (12) VI 14 (7) 3 (6) VII 2 (1) 0 (0) VIII 4 (2) 1 (2) IX 9 (4.”
van Leeuwen, M. S., Fernandez, M. A., Es, H., Stokking, R., Dillon, E. H., & Feldberg, M. A. M. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.162.6.8191995 · Cited by 56 · cited 1×
“arising from a right portal venous branch, may alter segmental definition and also substantially affect surgical approach (34).”
BackgroundBurkart, D. J., Johnson, C. D., Ehman, R. L., Weaver, A. L., & Ilstrup, D. M. (1993) · Radiology · doi:10.1148/radiology.188.3.8351326 · Cited by 50 · cited 1×
“Better correlation between delayed or impaired portal venous enhancement with severity of portal hypertension may be possible with the advent of fast phase-contrast measurements of portal venous flow patterns (26).”
BackgroundCirrhosis: Multiobserver analysis of hepatic MR imaging findings in a heterogeneous population
Mitchell, D. G., Lovett, K. E., Hann, H. L., Ehrlich, S. M., Palazzo, J., & Rubin, R. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030204 · Cited by 28 · cited 1×
“t test for patients with (n 5 17) and those without (n 5 34) cirrhosis of the liver as determined by means of MR imaging features (19).”
Method
Cited by
Huppertz, A., Balzer, T., Blakeborough, A., Breuer, J., Giovagnoni, A., Heinz-Peer, G., Laniado, M., Manfredi, R. M., Mathieu, D. G., Mueller, D., et al. (2004) · Radiology · doi:10.1148/radiol.2301020269 · Cited by 396
Can imaging modalities diagnose and stage hepatic fibrosis and cirrhosis accurately?
Bonekamp, S., Kamel, I., Solga, S., & Clark, J. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2008.10.016 · Cited by 193
Kang, Y., Lee, J. M., Kim, S. H., Han, J. K., & Choi, B. I. (2012) · Radiology · doi:10.1148/radiol.12112308 · Cited by 189
Metadata
- Authors
- Lee, V. S., Lavelle, M. T., Rofsky, N. M., Laub, G., Thomasson, D. M., Krinsky, G. A., & Weinreb, J. C.
- Venue
- Radiology
- Published
- 2000-05
- Volume
- 215
- Issue
- 2
- Pages
- 365-372
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2152201949
- Cited by
- 182
- References
- 14
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.