Inferior Vena Caval Filters: Review of a 26-year Single-Center Clinical Experience
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE: To review a 26-year single-center clinical experience with inferior vena caval filters. MATERIALS AND METHODS: During 1973-1998, 1,765 filters were implanted in 1,731 patients. Hospital files were reviewed, and data were collected about the indications, safety, effectiveness, numbers, and types of caval filters. Fatal post-filter pulmonary embolism (PE) was considered the primary outcome. Morbidity and mortality were determined as secondary outcomes. Survival and morbidity-free survival curves were calculated. RESULTS: The prevalence of observed post-filter PE was 5.6%. It was fatal in 3.7% of patients. In most patients, fatal PE occurred soon after filter insertion (median, 4.0 days; 95% CI: 2.2, 5.8 days). Major complications occurred in 0.3% of procedures. The prevalence of observed post-filter caval thrombosis was 2.7%. The 30-day mortality rate was 17.0% overall, higher among patients with neoplasms (19.5%) as compared with those without neoplasms (14.3%; P =.004). Filter efficacy and associated morbidity were not different in 46 patients with suprarenal filters. The rate of filters placed for prophylaxis was 4.7% overall and increased to 16.4% in 1998. From 1980 to 1996, there was a fivefold increase in the number of caval filter implants. In recent years, more filters were implanted in younger patients. CONCLUSION: Inferior vena caval filters provide protection from life-threatening PE, with minimal morbidity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inferior Vena Cava Filters: Indications, Safety, Effectiveness
Becker, D. M. (1992) · Archives of Internal Medicine · doi:10.1001/archinte.1992.00400220023005 · Cited by 360
Percutaneous inferior vena caval filters: follow-up of seven designs in 320 patients.
Ferris, E. J., McCowan, T. C., Carver, D. K., & McFarland, D. R. (1993) · Radiology · doi:10.1148/radiology.188.3.8351361 · Cited by 301
A new intracaval filter permitting continued flow and resolution of emboli.
Greenfield, L. J., McCurdy, J. R., Brown, P. P., & Elkins, R. C. (1973) · PubMed · Cited by 282
Twenty-year clinical experience with the Greenfield filter
Greenfield, L. (1995) · Cardiovascular Surgery · doi:10.1016/0967-2109(95)90895-c · Cited by 188
Simon nitinol inferior vena cava filter: initial clinical experience. Work in progress.
Simon, M., Athanasoulis, C. A., Kim, D., Steinberg, F. L., Porter, D. H., Byse, B. H., Kleshinski, S., Geller, S. C., Orron, D. E., & Waltman, A. C. (1989) · Radiology · doi:10.1148/radiology.172.1.2662259 · Cited by 132
Self-citationA Vena Cava Filter Using Thermal Shape Memory Alloy
Simon, M., Kaplow, R., Salzman, E. W., & Freiman, D. B. (1977) · Radiology · doi:10.1148/125.1.89 · Cited by 107
Vena Tech-LGM filter: long-term results of a prospective study.
Crochet, D., Stora, O., Ferry, D., Grossetête, R., Leurent, B., Brunel, P., & Nguyen, J. (1993) · Radiology · doi:10.1148/radiology.188.3.8351362 · Cited by 102
Extended indications for placement of an inferior vena cava filter
Rohrer, M. J., Scheidler, M. G., Wheeler, H. B., & Cutler, B. S. (1989) · Journal of Vascular Surgery · doi:10.1016/0741-5214(89)90284-x · Cited by 100
Greenfield, L. J., & Proctor, M. (1998) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(98)70128-4 · Cited by 86
Evaluation of a New Percutaneous Stainless Steel Greenfield Filter
Cho, K. J., Greenfield, L. J., Proctor, M., Hausmann, L. A., Bonn, J., Dolmatch, B. L., Eschelman, D. J., Flick, P. A., Kinney, T. B., Marx, M. V., et al. (1997) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(97)70536-0 · Cited by 54
Self-citation
Cited by
Kearon (2012) · doi:10.1378/chest.11-2301 · Cited by 6,119
Antithrombotic Therapy for VTE Disease
Kearon, C., Akl, E. A., Ornelas, J., Blaivas, A., Jimenez, D., Bounameaux, H., Huisman, M., King, C. S., Morris, T. A., Sood, N., et al. (2016) · Chest · doi:10.1016/j.chest.2015.11.026 · Cited by 4,830
Antithrombotic Therapy for Venous Thromboembolic Disease
Büller, H. R., Agnelli, G., Hull, R. D., Hyers, T. M., Prins, M. H., & Raskob, G. E. (2004) · Chest · doi:10.1378/chest.126.3_suppl.401s · Cited by 1,249
Mismetti, P., Laporte, S., Pellerin, O., Ennezat, P.-V., Couturaud, F., Elias, A., Falvo, N., Meneveau, N., Quere, I., Roy, P.-M., et al. (2015) · JAMA · doi:10.1001/jama.2015.3780 · Cited by 489
“Patients were excluded (1) if insertion of a vena cava filter was indicated because of a transient or permanent contraindication to anticoagulation therapy or because recurrent thromboembolism had occurred despite adequate anticoagulant therapy, (2) if a vena cava filter had already been inserted, (3) if a thrombosis…”
BackgroundKaufman, J. A., Kinney, T. B., Streiff, M. B., Sing, R. F., Proctor, M. C., Becker, D., Cipolle, M., Comerota, A. J., Millward, S. F., Rogers, F. B., et al. (2006) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000203418-39769.0d · Cited by 413
Self-citationUpdate on Inferior Vena Cava Filters
Kinney, T. B. (2003) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000064860.87207.77 · Cited by 355
Twenty-one-Year Trends in the Use of Inferior Vena Cava Filters
Stein, P. D., Kayali, F., & Olson, R. E. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.14.1541 · Cited by 329
Thrombolytic Therapy in Unstable Patients with Acute Pulmonary Embolism: Saves Lives but Underused
Stein, P. D., & Matta, F. (2012) · The American Journal of Medicine · doi:10.1016/j.amjmed.2011.10.015 · Cited by 293
Caplin, D. M., Nikolic, B., Kalva, S. P., Ganguli, S., Saad, W. E. A., & Zuckerman, D. A. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2011.07.012 · Cited by 278
Sapala, J. A., Wood, M. H., Schuhknecht, M. P., & Sapala, M. A. (2003) · Obesity Surgery · doi:10.1381/096089203322618588 · Cited by 261
The role of vena caval filters in the management of venous thromboembolism
HANN, C., & STREIFF, M. (2005) · Blood Reviews · doi:10.1016/j.blre.2004.08.002 · Cited by 202
Minocha, J., Idakoji, I., Riaz, A., Karp, J., Gupta, R., Chrisman, H. B., Salem, R., Ryu, R. K., & Lewandowski, R. J. (2010) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2010.09.003 · Cited by 197
Durack, J. C., Westphalen, A. C., Kekulawela, S., Bhanu, S. B., Avrin, D. E., Gordon, R. L., & Kerlan, R. K. (2012) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-011-0151-9 · Cited by 177
Impact of Vena Cava Filters on In-hospital Case Fatality Rate from Pulmonary Embolism
Stein, P. D., Matta, F., Keyes, D. C., & Willyerd, G. L. (2012) · The American Journal of Medicine · doi:10.1016/j.amjmed.2011.05.025 · Cited by 177
Outcomes with Retrievable Inferior Vena Cava Filters: A Multicenter Study
Ray, C. E., Mitchell, E., Zipser, S., Kao, E. Y., Brown, C. F., & Moneta, G. L. (2006) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000239102.02956.65 · Cited by 176
Increasing Use of Vena Cava Filters for Prevention of Pulmonary Embolism
Stein, P. D., Matta, F., & Hull, R. D. (2011) · The American Journal of Medicine · doi:10.1016/j.amjmed.2011.02.021 · Cited by 162
Inferior vena cava thrombosis: A review of current practice
McAree, B., O’Donnell, M., Fitzmaurice, G., Reid, J., Spence, R., & Lee, B. (2013) · Vascular Medicine · doi:10.1177/1358863x12471967 · Cited by 162
Postthrombotic syndrome in relation to vena cava filter placement: a systematic review
Fox, M. A., & Kahn, S. R. (2008) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2008.03.022 · Cited by 45
Jiang, J., Jiao, Y., & Zhang, X. (2017) · Phlebology: The Journal of Venous Disease · doi:10.1177/0268355516669004 · Cited by 10
Metadata
- Authors
- Athanasoulis, C. A., Kaufman, J. A., Halpern, E. F., Waltman, A. C., Geller, S. C., & Fan, C.-M.
- Venue
- Radiology
- Published
- 2000-07
- Volume
- 216
- Issue
- 1
- Pages
- 54-66
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2028593097
- Cited by
- 370
- References
- 13
- FWCI
- 8.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.