Abdominal Helical CT: Evaluation of Optimal Doses of Intravenous Contrast Material—A Prospective Randomized Study
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the optimal dose of intravenous contrast material for helical computed tomography (CT) of the abdomen on the basis of patient weight. MATERIALS AND METHODS: A prospective randomized study of helical CT of the abdomen was performed by using different doses of intravenous contrast material in 221 patients (mean body weight, 57.3 kg) who were assigned randomly to three groups receiving 1.5, 2.0, or 2.5 mL/kg or a fixed dose of 100 mL of iopamidol 300. The degree of enhancement was scored visually. The CT numbers (HU) of the aorta, portal vein, liver, and pancreas were obtained at three levels of the abdomen. RESULTS: In arterial enhancement, the 2.0 mL/kg, 2.5 mL/kg, and fixed-dose groups were significantly better than the 1.5 mL/kg group, but there was no significant difference among the 2.0 mL/kg, 2.5 mL/kg, or fixed-dose groups. The degree of enhancement of the liver, pancreas, and portal vein increased with larger doses. At visual analysis, hepatic parenchymal enhancement was graded as good or excellent in 64% of the 1.5 mL/kg, 85% of the 2.0 mL/kg, 94% of the 2.5 mL/kg, and 65% of the fixed-dose groups. CONCLUSION: When dose was tailored to patient weight, the use of 2.0-2.5 mL/kg of intravenous contrast material produced better results than did 1.5 mL/kg or a fixed dose. Arterial enhancement did not differ among the 2.0 mL/kg, 2.5 mL/kg, or fixed-dose groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mitsuzaki, K., Yamashita, Y., Ogata, I., Nishiharu, T., Urata, J., & Takahashi, M. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.167.3.8751695 · Cited by 160
Self-citationEffect of Injection Rate of Contrast Medium on Pancreatic and Hepatic Helical CT
TUBLIN, M. E., Tessler, F. N., Cheng, S. L., Peters, T. L., & McGovern, P. C. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja2197 · Cited by 135
Pancreatic CT Imaging: Effects of Different Injection Rates and Doses of Contrast Material
Kim, T., Murakami, T., Takahashi, S., Okada, A., Hori, M., Narumi, Y., & Nakamura, H. (1999) · Radiology · doi:10.1148/radiology.212.1.r99jl06219 · Cited by 99
Cited by
Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches
Bae, K. T. (2010) · Radiology · doi:10.1148/radiol.10090908 · Cited by 1,067
Effects of Nonionic Intravenous Contrast Agents at PET/CT Imaging: Phantom and Canine Studies
Nakamoto, Y., Chin, B. B., Kraitchman, D. L., Lawler, L. P., Marshall, L. T., & Wahl, R. L. (2003) · Radiology · doi:10.1148/radiol.2273020299 · Cited by 111
Metadata
- Authors
- Yamashita, Y., Komohara, Y., Takahashi, M., Uchida, M., Hayabuchi, N., Shimizu, T., & Narabayashi, I.
- Venue
- Radiology
- Published
- 2000-09
- Volume
- 216
- Issue
- 3
- Pages
- 718-723
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2093599551
- Cited by
- 250
- References
- 3
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Abdominal Helical CT: Evaluation of Optimal Doses of Intravenous Contrast Material—A Prospective Randomized Study. https://app.cochat.ai/papers/10.1148/radiology.216.3.r00se26718
- The paper
- Yamashita, Y., Komohara, Y., Takahashi, M., Uchida, M., Hayabuchi, N., Shimizu, T., & Narabayashi, I. (2000). Abdominal Helical CT: Evaluation of Optimal Doses of Intravenous Contrast Material—A Prospective Randomized Study. Radiology. https://doi.org/10.1148/radiology.216.3.r00se26718
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.