Are Two-dimensional CT Measurements of Small Noncalcified Pulmonary Nodules Reliable?

Revel, Marie-Pierre, Bissery, Alvine, Bienvenu, Marie, Aycard, Laetitia, Lefort, Catherine, Frija, Guy·2004·Radiology

Abstract

PURPOSE: To evaluate the intra- and interreader agreement of two-dimensional computed tomographic (CT) measurements of pulmonary nodules less than 2 cm in diameter. MATERIALS AND METHODS: Three readers independently made three serial measurements of each of 54 pulmonary nodules measuring 3-18 mm that had been observed on standard-dose multisection CT images obtained in 24 patients who ranged in age from 36 to 81 years (mean age, 54.6 years). There were 14 women (58%), who ranged in age from 43 to 81 years (mean age, 58.9 years), and 10 men (42%), who ranged in age from 36 to 65 years (mean age, 48.5 years). The largest transverse cross-sectional diameter of each nodule was measured at picture archiving and communication system, or PACS, workstations by using high-spatial-resolution reconstructed CT images and identical window settings. Intra- and interreader agreement were determined by using methods described by Bland and Altman: the coefficient of repeatability for intrareader agreement, and methods derived from the 95% limits of agreement defined by Bland and Altman for interreader agreement. RESULTS: The repeatability coefficients were 1.70, 1.32, and 1.51 mm for readers 1, 2, and 3, respectively. The 95% limits of agreement for the difference among readers were -1.73 and 1.73. CONCLUSION: Two-dimensional CT measurements are not reliable in the evaluation of small noncalcified pulmonary nodules.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2312030167

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 345

Metadata

Authors
Revel, M.-P., Bissery, A., Bienvenu, M., Aycard, L., Lefort, C., & Frija, G.
Venue
Radiology
Published
2004-05
Volume
231
Issue
2
Pages
453-458
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W1990185451
Cited by
345
References
13
FWCI
9.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Are Two-dimensional CT Measurements of Small Noncalcified Pulmonary Nodules Reliable? https://app.cochat.ai/papers/10.1148/radiol.2312030167
The paper
Revel, M.-P., Bissery, A., Bienvenu, M., Aycard, L., Lefort, C., & Frija, G. (2004). Are Two-dimensional CT Measurements of Small Noncalcified Pulmonary Nodules Reliable? Radiology. https://doi.org/10.1148/radiol.2312030167

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.