MR Evaluation of Ventricular Function: True Fast Imaging with Steady-State Precession versus Fast Low-Angle Shot Cine MR Imaging: Feasibility Study
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Short- and long-axis cine magnetic resonance (MR) images were obtained with a standard fast low-angle shot, or FLASH, sequence and a first-generation true fast imaging with steady-state precession (FISP) sequence on a 1.5-T MR imager. Contrast-to-noise ratios and volumetric left ventricular measurements were compared for manual and automatic segmentation. True FISP images were associated with significantly (P<.01) higher contrast-to-noise ratios and allowed better detection of the endocardial border. True FISP images were provided with short acquisition times and excellent contrast between the myocardium and the ventricular lumen.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
van der Geest, R. J., Buller, V. G. M., Jansen, E., Lamb, H. J., Baur, L. H. B., van der Wall, E. E., Roos, A., & Reiber, J. H. C. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199709000-00019 · Cited by 226
Cine MR determination of left ventricular ejection fraction
Utz, J. A., Herfkens, R. J., Heinsimer, J. A., Bashore, T. M., Califf, R. M., Glover, G. H., Pelc, N. J., & Shimakawa, A. S. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.5.839 · Cited by 117
Higgins, C. B. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90626-x · Cited by 91
Debatin, J. F., Nadel, S. N., Paolini, J. F., Sostman, H. D., Coleman, R. E., Evans, A. J., Beam, C. A., Spritzer, C. E., & Bashore, T. M. (1992) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880020205 · Cited by 67
Self-citationFurber, A., Balzer, P., Cavaro‐Ménard, C., Croué, A., Costa, E. D., Lethimonnier, F., Geslin, P., Tadéi, A., JALLET, P., & Jeune, J. L. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080503 · Cited by 52
Use of an intravascular T1 contrast agent to improve MR cine myocardial‐blood pool definition in man
Stillman, A. E., Wilke, N. M., & Jerosch‐Herold, M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070425 · Cited by 51
Lalande, A., LEGRAND, L., WALKER, P. M., Guy, F., Cottin, Y., ROY, S., & Brunotte, F. (1999) · Investigative Radiology · doi:10.1097/00004424-199903000-00010 · Cited by 37
Cited by
WRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Principles and applications of balanced SSFP techniques
Scheffler, K., & Lehnhardt, S. (2003) · European Radiology · doi:10.1007/s00330-003-1957-x · Cited by 714
ACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
JCS 2018 Guideline on Diagnosis and Treatment of Acute Coronary Syndrome
Kimura, K., Kimura, T., Ishihara, M., Nakagawa, Y., Nakao, K., Miyauchi, K., Sakamoto, T., Tsujita, K., Hagiwara, N., Miyazaki, S., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0133 · Cited by 565
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.005 · Cited by 484
Kwong, R. Y., Schussheim, A. E., Rekhraj, S., Aletras, A. H., Geller, N., Davis, J., Christian, T. F., Balaban, R. S., & Arai, A. E. (2003) · Circulation · doi:10.1161/01.cir.0000047527.11221.29 · Cited by 354
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler-Klein, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet123 · Cited by 353
Stem Cells for Myocardial Regeneration
Orlic, D., Hill, J. M., & Arai, A. E. (2002) · Circulation Research · doi:10.1161/01.res.0000046045.00846.b0 · Cited by 336
LV Mass Assessed by Echocardiography and CMR, Cardiovascular Outcomes, and Medical Practice
Armstrong, A. C., Gidding, S., Gjesdal, O., Wu, C., Bluemke, D. A., & Lima, J. A. C. (2012) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2012.06.003 · Cited by 321
Plein, S., Bloomer, T. N., Ridgway, J. P., Jones, T. R., Bainbridge, G. J., & Sivananthan, M. U. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1178 · Cited by 257
Kamat, A. M., Flaig, T. W., Grossman, H. B., Konety, B., Lamm, D., O'Donnell, M. A., Uchio, E., Efstathiou, J. A., & Taylor, J. A. (2015) · Nature Reviews Urology · doi:10.1038/nrurol.2015.58 · Cited by 252
Alfakih, K., Plein, S., Bloomer, T., Jones, T., Ridgway, J., & Sivananthan, M. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10329 · Cited by 246
Schelbert, E. B., Testa, S. M., Meier, C. G., Ceyrolles, W. J., Levenson, J. E., Blair, A. J., Kellman, P., Jones, B. L., Ludwig, D. R., Schwartzman, D., et al. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-16 · Cited by 242
“We measured T1 on a 1.5 T Siemens scanner using a single-shot modified Look Locker inversion recovery sequence (MOLLI) with balanced SSFP.”
BackgroundMethodInfluentialCardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
“5 Tesla the balanced SSFP gradient echo sequence is used for most functional imaging applications and volumetric assessments due to the high intrinsic contrast it achieves between blood and myocardium throughout the cardiac cycle [30-33].”
Yamamuro, M., Tadamura, E., Kubo, S., Toyoda, H., Nishina, T., Ohba, M., Hosokawa, R., Kimura, T., Tamaki, N., Komeda, M., et al. (2005) · Radiology · doi:10.1148/radiol.2342031271 · Cited by 233
Cardiovascular magnetic resonance physics for clinicians: part I
Ridgway, J. P. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-71 · Cited by 218
“5 Tesla the balanced SSFP gradient echo sequence is used for most functional imaging applications and volumetric assessments due to the high intrinsic contrast it achieves between blood and myocardium throughout the cardiac cycle [30-33].”
Papavassiliu, T., Kühl, H. P., Schröder, M., Süselbeck, T., Bondarenko, O., Böhm, C. K., Beek, A., Hofman, M. M. B., & van Rossum, A. C. (2005) · Radiology · doi:10.1148/radiol.2353040601 · Cited by 215
Cardiac MR Imaging: State of the Technology
Finn, J. P., Nael, K., Deshpande, V., Ratib, O., & Laub, G. (2006) · Radiology · doi:10.1148/radiol.2412041866 · Cited by 215
Self-citationGreupner, J., Zimmermann, E., Grohmann, A., Dübel, H.-P., Althoff, T., Borges, A. C., Rutsch, W., Schlattmann, P., Hamm, B., & Dewey, M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.046 · Cited by 193
“3 8 mm(3), acquisition window/cardiac phase: 34 s (24 segments per phase), slice resolution: 100%, and flip ngle: 54° (20,21).”
Cardiovascular magnetic resonance artefacts
Ferreira, P. F., Gatehouse, P. D., Mohiaddin, R. H., & Firmin, D. N. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-41 · Cited by 191
“bSSFP and GRE sequences are commonly used to assess cardiac function [25-28].”
BackgroundDetection and Characterization of Intracardiac Thrombi on MR Imaging
Barkhausen, J., Hunold, P., Eggebrecht, H., Schüler, W. O., Sabin, G. V., Erbel, R., & Debatin, J. F. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.6.1791539 · Cited by 188
Self-citationLeft and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR
Maffei, E., Messalli, G., Martini, C., Nieman, K., Catalano, O., Rossi, A., Seitun, S., Guaricci, A. I., Tedeschi, C., Mollet, N. R., et al. (2012) · European Radiology · doi:10.1007/s00330-011-2345-6 · Cited by 178
Noel, C. E., Parikh, P. J., Spencer, C. R., Green, O. L., Hu, Y., Mutic, S., & Olsen, J. R. (2015) · Acta Oncologica · doi:10.3109/0284186x.2015.1062541 · Cited by 159
“Volumetric axial-plane MR images were acquired for each patient using a fast gradient echo sequence (TrueFISP or turbo FLASH) [10] with parallel imaging techniques, as set by the manufacturer.”
MethodCardiac Magnetic Resonance Imaging for the Evaluation of Ventricular Function
Sarwar, A., Shapiro, M. D., Abbara, S., & Cury, R. C. (2008) · Seminars in Roentgenology · doi:10.1053/j.ro.2008.02.004 · Cited by 26
Metadata
- Authors
- Barkhausen, J., Ruehm, S. G., Goyen, M., Buck, T., Laub, G., & Debatin, J. F.
- Venue
- Radiology
- Published
- 2001-04
- Volume
- 219
- Issue
- 1
- Pages
- 264-269
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2158141700
- Cited by
- 380
- References
- 8
- FWCI
- 24.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.