Four-dimensional Flow MRI: Principles and Cardiovascular Applications
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
In-plane phase-contrast (PC) imaging is now a routine component of MRI of regional blood flow in the heart and great vessels. In-plane PC MRI provides a volumetric, isotropic, time-resolved cine sequence that enables three-directional velocity encoding, a technique known as four-dimensional (4D) flow MRI. Recent advances in 4D flow MRI have shortened imaging times, while progress in big-data processing has improved dataset pre- and postprocessing, thereby increasing the feasibility of 4D flow MRI in clinical practice. Important technical issues include selection of the optimal velocity-encoding sensitivity before acquisition and preprocessing of the raw data for phase-offset corrections. Four-dimensional flow MRI provides unprecedented capabilities for comprehensive analysis of complex blood flow patterns using new visualization tools such as streamlines and velocity vectors. Retrospective multiplanar navigation enables flexible retrospective flow quantification through any plane across the volume with good accuracy. Current flow parameters include forward flow, reverse flow, regurgitation fraction, and peak velocity. Four-dimensional flow MRI also supplies advanced flow parameters of use for research, such as wall shear stress. The vigorous burgeoning of new applications indicates that 4D flow MRI is becoming an important imaging modality for cardiovascular disorders. This article reviews the main technical issues of 4D flow MRI and the different parameters provided by it and describes the main applications in cardiovascular diseases, including congenital heart disease, cardiac valvular disease, aortic disease, and pulmonary hypertension. Online supplemental material is available for this article. ©RSNA, 2019 See discussion on this article by Ordovas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Kilner, P. J., Yang, G. Z., Mohiaddin, R. H., Firmin, D. N., & Longmore, D. B. (1993) · Circulation · doi:10.1161/01.cir.88.5.2235 · Cited by 592 · cited 1×
“Although 4D flow MRI was introduced in the 1990s (4), it entered the field of clinical practice only recently, after multiple improvements produced faster sequences, lighter datasets, big-data analysis software that was more user-friendly and accurate, more powerful graphics processing units (GPUs), and cloud-based po…”
Maceira, A. M., Prasad, S. K., Khan, M., & Pennell, D. J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl336 · Cited by 561 · cited 1×
“Cardiac MRI is the current reference standard for measuring both right and left ventricular volumes (20,21).”
BackgroundDavlouros, P. A., Kilner, P. J., Hornung, T. S., Li, W., Francis, J. M., Moon, J. C. C., Smith, G. C., Tat, T., Pennell, D. J., & Gatzoulis, M. A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02566-4 · Cited by 553 · cited 1×
“—Two-dimensional cine PC sequences are widely used for MRI assessment of pulmonary regurgitation (29).”
BackgroundMeasurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique
Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00002 · Cited by 545
Markl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463 · cited 3×
“New measurement sites can be assessed retrospectively and interactively, and new strategies can be developed to refine the diagnosis (6).”
BackgroundMethodMahadevia, R., Barker, A. J., Schnell, S., Entezari, P., Kansal, P., Fedak, P. W. M., Malaisrie, S. C., McCarthy, P., Collins, J., Carr, J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.003026 · Cited by 413 · cited 3×
“Although vascular tissue changes have been described, BAV also induces hemodynamic flow turbulence that may contribute to aneurysm formation and growth (39).”
BackgroundMethodBürk, J., Blanke, P., Stankovic, Z., Barker, A., Russe, M., Geiger, J., Frydrychowicz, A., Langer, M., & Markl, M. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-84 · Cited by 241 · cited 1×
“WSS reflects the effect of flow changes on endothelial-cell and extracellular-matrix function (14,15).”
BackgroundFlow Measurement by Magnetic Resonance: A Unique Asset Worth Optimising
Kilner, P. J., Gatehouse, P. D., & Firmin, D. N. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640701465090 · Cited by 205 · cited 1×
“Cardiac MRI is the current reference standard for measuring both right and left ventricular volumes (20,21).”
BackgroundBogren, H. G., & Buonocore, M. H. (1999) · Journal of Magnetic Resonance Imaging · Cited by 191 · cited 1×
“Abnormalities of the Great Vessels Early in vivo studies of cardiac 4D flow MRI evaluated blood flow path lines in the thoracic aorta and 3D quantification of thoracic aorta hemodynamics (37,38).”
Background
Cited by
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
Bissell, M. M., Raimondi, F., Ait Ali, L., Allen, B. D., Barker, A. J., Bolger, A., Burris, N., Carhäll, C.-J., Collins, J. D., Ebbers, T., et al. (2023) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-023-00942-z · Cited by 296
Aging Biomarker Consortium, Zhang, L., Guo, J., Liu, Y., Sun, S., Liu, B., Yang, Q., Tao, J., Tian, X.-L., Pu, J., et al. (2023) · Life Medicine · doi:10.1093/lifemedi/lnad033 · Cited by 60
Metadata
- Authors
- Azarine, A., Garçon, P., Stansal, A., Canepa, N., Angelopoulos, G., Silvera, S., Sidi, D., Marteau, V., & Zins, M.
- Venue
- RadioGraphics
- Published
- 2019-05
- Volume
- 39
- Issue
- 3
- Pages
- 632-648
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2924442307
- Cited by
- 193
- References
- 29
- FWCI
- 13.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.