Four-dimensional Flow MRI: Principles and Cardiovascular Applications
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
In-plane phase-contrast (PC) imaging is now a routine component of MRI of regional blood flow in the heart and great vessels. In-plane PC MRI provides a volumetric, isotropic, time-resolved cine sequence that enables three-directional velocity encoding, a technique known as four-dimensional (4D) flow MRI. Recent advances in 4D flow MRI have shortened imaging times, while progress in big-data processing has improved dataset pre- and postprocessing, thereby increasing the feasibility of 4D flow MRI in clinical practice. Important technical issues include selection of the optimal velocity-encoding sensitivity before acquisition and preprocessing of the raw data for phase-offset corrections. Four-dimensional flow MRI provides unprecedented capabilities for comprehensive analysis of complex blood flow patterns using new visualization tools such as streamlines and velocity vectors. Retrospective multiplanar navigation enables flexible retrospective flow quantification through any plane across the volume with good accuracy. Current flow parameters include forward flow, reverse flow, regurgitation fraction, and peak velocity. Four-dimensional flow MRI also supplies advanced flow parameters of use for research, such as wall shear stress. The vigorous burgeoning of new applications indicates that 4D flow MRI is becoming an important imaging modality for cardiovascular disorders. This article reviews the main technical issues of 4D flow MRI and the different parameters provided by it and describes the main applications in cardiovascular diseases, including congenital heart disease, cardiac valvular disease, aortic disease, and pulmonary hypertension. Online supplemental material is available for this article. ©RSNA, 2019 See discussion on this article by Ordovas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Kilner, P. J., Yang, G. Z., Mohiaddin, R. H., Firmin, D. N., & Longmore, D. B. (1993) · Circulation · doi:10.1161/01.cir.88.5.2235 · Cited by 592 · cited 1×
“Although 4D flow MRI was introduced in the 1990s (4), it entered the field of clinical practice only recently, after multiple improvements produced faster sequences, lighter datasets, big-data analysis software that was more user-friendly and accurate, more powerful graphics processing units (GPUs), and cloud-based po…”
Maceira, A. M., Prasad, S. K., Khan, M., & Pennell, D. J. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl336 · Cited by 561 · cited 1×
“Cardiac MRI is the current reference standard for measuring both right and left ventricular volumes (20,21).”
BackgroundDavlouros, P. A., Kilner, P. J., Hornung, T. S., Li, W., Francis, J. M., Moon, J. C. C., Smith, G. C., Tat, T., Pennell, D. J., & Gatzoulis, M. A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02566-4 · Cited by 553 · cited 1×
“—Two-dimensional cine PC sequences are widely used for MRI assessment of pulmonary regurgitation (29).”
BackgroundMeasurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique
Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00002 · Cited by 545
Markl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463 · cited 3×
“New measurement sites can be assessed retrospectively and interactively, and new strategies can be developed to refine the diagnosis (6).”
BackgroundMethodMahadevia, R., Barker, A. J., Schnell, S., Entezari, P., Kansal, P., Fedak, P. W. M., Malaisrie, S. C., McCarthy, P., Collins, J., Carr, J., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.003026 · Cited by 413 · cited 3×
“Although vascular tissue changes have been described, BAV also induces hemodynamic flow turbulence that may contribute to aneurysm formation and growth (39).”
BackgroundMethodBürk, J., Blanke, P., Stankovic, Z., Barker, A., Russe, M., Geiger, J., Frydrychowicz, A., Langer, M., & Markl, M. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-84 · Cited by 241 · cited 1×
“WSS reflects the effect of flow changes on endothelial-cell and extracellular-matrix function (14,15).”
BackgroundFlow Measurement by Magnetic Resonance: A Unique Asset Worth Optimising
Kilner, P. J., Gatehouse, P. D., & Firmin, D. N. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640701465090 · Cited by 205 · cited 1×
“Cardiac MRI is the current reference standard for measuring both right and left ventricular volumes (20,21).”
BackgroundBogren, H. G., & Buonocore, M. H. (1999) · Journal of Magnetic Resonance Imaging · Cited by 191 · cited 1×
“Abnormalities of the Great Vessels Early in vivo studies of cardiac 4D flow MRI evaluated blood flow path lines in the thoracic aorta and 3D quantification of thoracic aorta hemodynamics (37,38).”
BackgroundWestenberg, J. J. M., Roes, S. D., Ajmone Marsan, N., Binnendijk, N. M. J., Doornbos, J., Bax, J. J., Reiber, J. H. C., de Roos, A., & van der Geest, R. J. (2008) · Radiology · doi:10.1148/radiol.2492080146 · Cited by 190
Reiter, G., Reiter, U., Kovacs, G., Olschewski, H., & Fuchsjäger, M. (2015) · Radiology · doi:10.1148/radiol.14140849 · Cited by 174 · cited 2×
“Helicity has also been found to have strong diagnostic potential, suggesting that characterizing flow hemodynamics may become an important component of the initial and follow-up evaluations in patients with pulmonary hypertension (45).”
BackgroundReproducibility of flow and wall shear stress analysis using flow‐sensitive four‐dimensional MRI
Markl, M., Wallis, W., & Harloff, A. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22519 · Cited by 170
Clinical evaluation of aortic coarctation with 4D flow MR imaging
Hope, M. D., Meadows, A. K., Hope, T. A., Ordovas, K. G., Saloner, D., Reddy, G. P., Alley, M. T., & Higgins, C. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22083 · Cited by 166
Bock, J., Frydrychowicz, A., Stalder, A. F., Bley, T. A., Burkhardt, H., Hennig, J., & Markl, M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22199 · Cited by 166 · cited 1×
“Use of contrast agent significantly improves signal-to-noise ratio in magnitude data and noise reduction in velocity data compared to measurements without contrast agent (10).”
BackgroundUribe, S. A., Beerbaum, P., Sørensen, T. S., Rasmusson, A. G., Razavi, R., & Schaeffter, T. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22090 · Cited by 154 · cited 3×
“Many authors have described free-breathing 4D flow MRI (8) without respiratory gating, which results in shorter acquisition times.”
BackgroundCardiovascular Applications of Phase-Contrast MRI
Srichai, M. B., Lim, R., Wong, S., & Lee, V. S. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.07.3744 · Cited by 139
In vivo validation of 4D flow MRI for assessing the hemodynamics of portal hypertension
Roldán‐Alzate, A., Frydrychowicz, A. P., Niespodzany, E., Landgraf, B. R., Johnson, K. M., Wieben, O. E., & Reeder, S. B. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23906 · Cited by 124 · cited 1×
“Thus, 4D flow MRI has been studied in portal hypertension (46), cerebral aneurysm risk stratification (47), and complex arteriovenous malformations (48) (Fig 18).”
BackgroundComputation of flow pressure fields from magnetic resonance velocity mapping
Yang, G., Kilner, P. J., Wood, N. B., Underwood, S. R., & Firmin, D. N. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360404 · Cited by 122 · cited 1×
“Turbulence Kinetic Energy, Viscous Energy Loss, Pressure Difference Fields These parameters have been described as new tools for research (17), although pitfalls in their determination persist and the best measurement strategies remain unclear (18).”
4D-MR flow analysis in patients after repair for tetralogy of Fallot
Geiger, J., Markl, M., Jung, B. A., Grohmann, J., Stiller, B., Langer, M., & Arnold, R. (2011) · European Radiology · doi:10.1007/s00330-011-2108-4 · Cited by 121 · cited 2×
“In this population, cardiac 4D flow MRI has documented variations in flow characteristics (27).”
BackgroundBinter, C., Gotschy, A., Sündermann, S., Frank, M., Tanner, F. C., Lüscher, T. F., Manka, R., & Kozerke, S. (2017) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.116.005486 · Cited by 119 · cited 1×
“—Phantom and in vivo studies in patients with aortic stenosis showed promising results with cardiac 4D flow MRI, although further validation is required (34).”
BackgroundBollache, É., van Ooij, P., Powell, A., Carr, J., Markl, M., & Barker, A. J. (2016) · International journal of cardiac imaging · doi:10.1007/s10554-016-0938-5 · Cited by 73 · cited 1×
“Differences between 2D PC and 4D flow measurements were found—especially for the widely used ascending aorta flow—by Bollache et al (50), indicating that reference values should be established for each technique.”
MethodImaging congenital heart disease in adults
Kilner, P. J. (2011) · The British Journal of Radiology · doi:10.1259/bjr/74240815 · Cited by 71 · cited 2×
“This cavopulmonary connection eliminates shunting at the cost of a major increase in systemic venous pressure, which maintains flow through the lungs (24).”
BackgroundValente, A. M., Sena, L. M., Powell, A. J., del Nido, P. J., & Geva, T. (2007) · Pediatric Cardiology · doi:10.1007/s00246-006-1477-y · Cited by 67
Farag, E. S., van Ooij, P., Planken, R. N., Dukker, K. C. P., de Heer, F., Bouma, B. J., Robbers‐Visser, D., Groenink, M., Nederveen, A. J., de Mol, B. A. J. M., et al. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25956 · Cited by 64 · cited 1×
“In patients with BAV, the WSS increase in the ascending aorta was most pronounced in the presence of aortic stenosis and in the absence of dilatation of the ascending aorta (40).”
BackgroundKvitting, J. E., Dyverfeldt, P., Sigfridsson, A., Franzén, S., Wigström, L., Bolger, A. F., & Ebbers, T. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22163 · Cited by 60 · cited 1×
“Flow patterns and turbulence intensity downstream from a prosthetic heart valve are dependent on the specific valve design (35).”
MethodMuzzarelli, S., Monney, P. A., O’Brien, K., Faletra, F. F., Moccetti, T., Vogt, P. R., & Schwitter, J. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet129 · Cited by 39 · cited 1×
“Similarly, reported measurement errors with 2D PC MRI can be avoided when estimating the regurgitation fraction and volume in patients with moderate to severe aortic regurgitation and sinus of Valsalva dilatation (31).”
MethodCloud-processed 4D CMR flow imaging for pulmonary flow quantification
Chelu, R. G., Wanambiro, K., Hsiao, A., Swart, L. E., Voogd, T., van den Hoven, A. T., van Kranenburg, M., Coenen, A., Boccalini, S., Wielopolski, P. A., et al. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.07.018 · Cited by 36 · cited 1×
“Cardiac 4D flow MRI has shown good reliability and reproducibility for this indication (30) (Fig 9) (Movie 4).”
BackgroundHadizadeh, D. R., Jošt, G., Pietsch, H., Weibrecht, M., Perkuhn, M., Boschewitz, J. M., Keil, V. C., Träber, F., Kukuk, G. M., Schild, H. H., et al. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000036 · Cited by 20 · cited 1×
“The concentration and relaxivity of the contrast agent, the acquisition technique, and the injection protocol may influence image quality (11).”
Background
Cited by
4D Flow cardiovascular magnetic resonance consensus statement: 2023 update
Bissell, M. M., Raimondi, F., Ait Ali, L., Allen, B. D., Barker, A. J., Bolger, A., Burris, N., Carhäll, C.-J., Collins, J. D., Ebbers, T., et al. (2023) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-023-00942-z · Cited by 296
Aging Biomarker Consortium, Zhang, L., Guo, J., Liu, Y., Sun, S., Liu, B., Yang, Q., Tao, J., Tian, X.-L., Pu, J., et al. (2023) · Life Medicine · doi:10.1093/lifemedi/lnad033 · Cited by 60
Metadata
- Authors
- Azarine, A., Garçon, P., Stansal, A., Canepa, N., Angelopoulos, G., Silvera, S., Sidi, D., Marteau, V., & Zins, M.
- Venue
- RadioGraphics
- Published
- 2019-05
- Volume
- 39
- Issue
- 3
- Pages
- 632-648
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2924442307
- Cited by
- 193
- References
- 29
- FWCI
- 13.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.