CoChat

Role of Multidetector CT in Assessment of Repaired Tetralogy of Fallot

Ahmed, Sameer, Johnson, Pamela Tecce, Fishman, Elliot K., Zimmerman, Stefan Loy · 2013 · RadioGraphics
Cited by 40

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

The population of adults with repaired tetralogy of Fallot (TOF) is growing, thanks to improvements in the surgical and medical management of this condition. Accordingly, late postrepair complications are important medical concerns in these individuals. Initial surgical repair of TOF typically occurs in infancy, consisting of patch repair of the ventricular septal defect (VSD) and relief of right ventricular outflow tract (RVOT) obstruction. Although patients may remain asymptomatic for several decades, the majority will have progressive pulmonic regurgitation that leads to right ventricular (RV) dilatation and functional deterioration. Other frequently seen complications include branch pulmonary artery stenosis, RVOT aneurysms, and recurrent VSDs. Cardiac computed tomography (CT) is widely available and, in some cases, is the imaging modality of choice for serial evaluation of TOF patients. CT is particularly useful when magnetic resonance (MR) imaging is contraindicated (eg, in patients with implantable cardiac devices). Unlike MR imaging, cardiac CT allows excellent visualization of endovascular stents and stent-mounted valves. Retrospective electrocardiographically gated cardiac CT can be used for accurate volumetric and functional analysis of the RV. Comprehensive serial evaluation will assist in determining the need for surgical pulmonary valve repair in the setting of progressive RV dysfunction. Three-dimensional volumetric images are useful for evaluation of stent integrity and aneurysm formation. The radiologist should be familiar with the anatomy of TOF, surgical interventions for repair, and postrepair complications encountered at follow-up imaging of these patients. By extracting the breadth of information obtained with cardiac multidetector CT, the radiologist can play an essential role in the management of adult patients with repaired TOF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/rg.334125114

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 40

Metadata

Authors
Ahmed, S., Johnson, P. T., Fishman, E. K., & Zimmerman, S. L.
Venue
RadioGraphics
Published
2013-07
Volume
33
Issue
4
Pages
1023-1036
ISSN
  • 0271-5333 (ISSN-L)
  • 1527-1323
OpenAlex
W2144427158
Cited by
40
References
9
FWCI
1.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Role of Multidetector CT in Assessment of Repaired Tetralogy of Fallot. https://app.cochat.ai/papers/10.1148/rg.334125114
The paper
Ahmed, S., Johnson, P. T., Fishman, E. K., & Zimmerman, S. L. (2013). Role of Multidetector CT in Assessment of Repaired Tetralogy of Fallot. RadioGraphics. https://doi.org/10.1148/rg.334125114

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.