CoChat

Fully Automated Diagnosis of Anterior Cruciate Ligament Tears on Knee MR Images by Using Deep Learning

Open access
Liu, Fang, Guan, Bochen, Zhou, Zhaoye, Samsonov, Alexey, Rosas, Humberto, Lian, Kevin, Sharma, Ruchi, Kanarek, Andrew, Kim, John, Guermazi, Ali, Kijowski, Richard · 2019 · Radiology: Artificial Intelligence
Cited by 176

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Purpose To investigate the feasibility of using a deep learning–based approach to detect an anterior cruciate ligament (ACL) tear within the knee joint at MRI by using arthroscopy as the reference standard. Materials and Methods A fully automated deep learning–based diagnosis system was developed by using two deep convolutional neural networks (CNNs) to isolate the ACL on MR images followed by a classification CNN to detect structural abnormalities within the isolated ligament. With institutional review board approval, sagittal proton density–weighted and fat-suppressed T2-weighted fast spin-echo MR images of the knee in 175 subjects with a full-thickness ACL tear (98 male subjects and 77 female subjects; average age, 27.5 years) and 175 subjects with an intact ACL (100 male subjects and 75 female subjects; average age, 39.4 years) were retrospectively analyzed by using the deep learning approach. Sensitivity and specificity of the ACL tear detection system and five clinical radiologists for detecting an ACL tear were determined by using arthroscopic results as the reference standard. Receiver operating characteristic (ROC) analysis and two-sided exact binomial tests were used to further assess diagnostic performance. Results The sensitivity and specificity of the ACL tear detection system at the optimal threshold were 0.96 and 0.96, respectively. In comparison, the sensitivity of the clinical radiologists ranged between 0.96 and 0.98, while the specificity ranged between 0.90 and 0.98. There was no statistically significant difference in diagnostic performance between the ACL tear detection system and clinical radiologists at P < .05. The area under the ROC curve for the ACL tear detection system was 0.98, indicating high overall diagnostic accuracy. Conclusion There was no significant difference between the diagnostic performance of the ACL tear detection system and clinical radiologists for determining the presence or absence of an ACL tear at MRI. Keywords: Computer Aided Diagnosis (CAD), Computer Applications-Detection/Diagnosis, Knee, Ligaments, MR-Imaging, Neural Networks © RSNA, 2019 Supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/ryai.2019180091

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 176

Metadata

Authors
Liu, F., Guan, B., Zhou, Z., Samsonov, A., Rosas, H., Lian, K., Sharma, R., Kanarek, A., Kim, J., Guermazi, A., & Kijowski, R.
Venue
Radiology: Artificial Intelligence
Published
2019-05
Volume
1
Issue
3
Pages
180091
ISSN
2638-6100 (ISSN-L)
OpenAlex
W2944480979
Cited by
176
References
13
FWCI
17.07
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fully Automated Diagnosis of Anterior Cruciate Ligament Tears on Knee MR Images by Using Deep Learning. https://app.cochat.ai/papers/10.1148/ryai.2019180091
The paper
Liu, F., Guan, B., Zhou, Z., Samsonov, A., Rosas, H., Lian, K., Sharma, R., Kanarek, A., Kim, J., Guermazi, A., & Kijowski, R. (2019). Fully Automated Diagnosis of Anterior Cruciate Ligament Tears on Knee MR Images by Using Deep Learning. Radiology: Artificial Intelligence. https://doi.org/10.1148/ryai.2019180091

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.