The DOI matches its Crossref record; 116 of the 116 references it cites were found in a registry or an index.
External Validation of Deep Learning Algorithms for Radiologic Diagnosis: A Systematic Review
Open accessAbstract
Purpose To assess generalizability of published deep learning (DL) algorithms for radiologic diagnosis. Materials and Methods In this systematic review, the PubMed database was searched for peer-reviewed studies of DL algorithms for image-based radiologic diagnosis that included external validation, published from January 1, 2015, through April 1, 2021. Studies using nonimaging features or incorporating non-DL methods for feature extraction or classification were excluded. Two reviewers independently evaluated studies for inclusion, and any discrepancies were resolved by consensus. Internal and external performance measures and pertinent study characteristics were extracted, and relationships among these data were examined using nonparametric statistics. Results Eighty-three studies reporting 86 algorithms were included. The vast majority (70 of 86, 81%) reported at least some decrease in external performance compared with internal performance, with nearly half (42 of 86, 49%) reporting at least a modest decrease (≥0.05 on the unit scale) and nearly a quarter (21 of 86, 24%) reporting a substantial decrease (≥0.10 on the unit scale). No study characteristics were found to be associated with the difference between internal and external performance. Conclusion Among published external validation studies of DL algorithms for image-based radiologic diagnosis, the vast majority demonstrated diminished algorithm performance on the external dataset, with some reporting a substantial performance decrease. Keywords: Meta-Analysis, Computer Applications–Detection/Diagnosis, Neural Networks, Computer Applications–General (Informatics), Epidemiology, Technology Assessment, Diagnosis, Informatics Supplemental material is available for this article. © RSNA, 2022
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Rudin, C. (2019) · Nature Machine Intelligence · doi:10.1038/s42256-019-0048-x · Cited by 10,561
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · Annals of Internal Medicine · doi:10.7326/m14-0697 · Cited by 3,267
Zech, J. R., Badgeley, M. A., Liu, M., Costa, A. B., Titano, J. J., & Oermann, E. K. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002683 · Cited by 1,719
Rajpurkar, P., Irvin, J., Ball, R. L., Zhu, K., Yang, B., Mehta, H., Duan, T., Ding, D., Bagul, A., Langlotz, C. P., et al. (2018) · PLOS Medicine · doi:10.1371/journal.pmed.1002686 · Cited by 1,449
Checklist for Artificial Intelligence in Medical Imaging (CLAIM): a guide for authors and reviewers
Mongan, J., Moy, L., & Kahn, C. E. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020200029 · Cited by 1,443
STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Radiology · doi:10.1148/radiol.2015151516 · Cited by 1,337
Automated breast ultrasound lesions detection using convolutional neural networks
Yap, M. H., Pons, G., Martí, J., Ganau, S., Sentís, M., Zwiggelaar, R., Davison, A. K., & Martí, R. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2731873 · Cited by 1,086
Cited by
AI pitfalls and what not to do: mitigating bias in AI
Gichoya, J. W., Thomas, K., Celi, L. A., Safdar, N., Banerjee, I., Banja, J. D., Seyyed-Kalantari, L., Trivedi, H., & Purkayastha, S. (2023) · The British Journal of Radiology · doi:10.1259/bjr.20230023 · Cited by 277
“57 Even on what would be considered a small sample size for external validation, nearly half of the 86 studies reported a modest increase in external performance with nearly a quarter reporting a substantial decrease, reiterating on the challenge of validation.”
External validation of AI models in health should be replaced with recurring local validation
Youssef, A., Pencina, M., Thakur, A., Zhu, T., Clifton, D., & Shah, N. H. (2023) · Nature Medicine · doi:10.1038/s41591-023-02540-z · Cited by 170
Understanding and Mitigating Bias in Imaging Artificial Intelligence
Tejani, A. S., Ng, Y. S., Xi, Y., & Rayan, J. C. (2024) · RadioGraphics · doi:10.1148/rg.230067 · Cited by 138
Mastrodicasa, D., van Assen, M., Huisman, M., Leiner, T., Williamson, E. E., Nicol, E. D., Allen, B. D., Saba, L., Vliegenthart, R., & Hanneman, K. (2025) · Radiology · doi:10.1148/radiol.240516 · Cited by 69
FDA Review of Radiologic AI Algorithms: Process and Challenges
Zhang, K., Khosravi, B., Vahdati, S., & Erickson, B. J. (2024) · Radiology · doi:10.1148/radiol.230242 · Cited by 46
Metadata
- Authors
- Yu, A. C., Mohajer, B., & Eng, J.
- Venue
- Radiology: Artificial Intelligence
- Published
- 2022-05-01
- Volume
- 4
- Issue
- 3
- Pages
- e210064-e210064
- ISSN
- 2638-6100 (ISSN-L)
- OpenAlex
- W4229036772
- Cited by
- 408
- References
- 116
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: External Validation of Deep Learning Algorithms for Radiologic Diagnosis: A Systematic Review. https://app.cochat.ai/papers/10.1148/ryai.210064
- The paper
- Yu, A. C., Mohajer, B., & Eng, J. (2022). External Validation of Deep Learning Algorithms for Radiologic Diagnosis: A Systematic Review. Radiology: Artificial Intelligence. https://doi.org/10.1148/ryai.210064
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.