Overview of Noninterpretive Artificial Intelligence Models for Safety, Quality, Workflow, and Education Applications in Radiology Practice
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Artificial intelligence has become a ubiquitous term in radiology over the past several years, and much attention has been given to applications that aid radiologists in the detection of abnormalities and diagnosis of diseases. However, there are many potential applications related to radiologic image quality, safety, and workflow improvements that present equal, if not greater, value propositions to radiology practices, insurance companies, and hospital systems. This review focuses on six major categories for artificial intelligence applications: study selection and protocoling, image acquisition, worklist prioritization, study reporting, business applications, and resident education. All of these categories can substantially affect different aspects of radiology practices and workflows. Each of these categories has different value propositions in terms of whether they could be used to increase efficiency, improve patient safety, increase revenue, or save costs. Each application is covered in depth in the context of both current and future areas of work. Keywords: Use of AI in Education, Application Domain, Supervised Learning, Safety © RSNA, 2022
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Convolutional Neural Network for Inverse Problems in Imaging
Jin, K. H., McCann, M. T., Froustey, E., & Unser, M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2713099 · Cited by 2,529
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058
Image reconstruction by domain-transform manifold learning
Zhu, B., Liu, J. Z., Cauley, S. F., Rosen, B. R., & Rosen, M. S. (2018) · Nature · doi:10.1038/nature25988 · Cited by 1,694 · cited 1×
“Image reconstruction is fundamental to medical imaging to create high-quality diagnostic images while managing cost, reconstruction time, and risk to the patient (34,35).”
BackgroundRasmy, L., Xiang, Y., Xie, Z., Tao, C., & Zhi, D. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00455-y · Cited by 886
Deep learning in medical image registration: a survey
Haskins, G., Kruger, U., & Yan, P. (2020) · Machine Vision and Applications · doi:10.1007/s00138-020-01060-x · Cited by 704 · cited 2×
“Haskins et al (52) published a comprehensive list of image registration applications.”
BackgroundBEHRT: Transformer for Electronic Health Records
Li, Y., Rao, S., Solares, J. R. A., Hassaine, A., Ramakrishnan, R., Canoy, D., Zhu, Y., Rahimi, K., & Salimi-Khorshidi, G. (2020) · Scientific Reports · doi:10.1038/s41598-020-62922-y · Cited by 595
Natural language processing in radiology: a systematic review
Pons, E., Braun, L. M. M., Hunink, M. G. M., & Kors, J. A. (2016) · Radiology · doi:10.1148/radiol.16142770 · Cited by 573 · cited 1×
“For example, models have been created to improve patient care by automatically populating recommendations for follow-up of incidental findings (74–77).”
BackgroundArbabshirani, M. R., Fornwalt, B. K., Mongelluzzo, G. J., Suever, J. D., Geise, B. D., Patel, A. A., & Moore, G. J. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0015-z · Cited by 443 · cited 2×
“Arbabshirani et al (64) prospectively implemented a prioritization system for detection of intracranial hemorrhage at head CT, which flagged 94 of 347 routine cases (60 true-positive findings, 34 false-positive (Adapted, with permission, from reference 50.)”
BackgroundDeep learning enables reduced gadolinium dose for contrast-enhanced brain MRI
Gong, E., Pauly, J. M., Wintermark, M., & Zaharchuk, G. (2018) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25970 · Cited by 351 · cited 2×
“MRI does not produce ionizing radiation, but researchers have explored machine learning techniques to reduce gadolinium-based intravenous contrast agent dosage (33).”
BackgroundAutomated Triaging of Adult Chest Radiographs with Deep Artificial Neural Networks
Annarumma, M., Withey, S. J., Bakewell, R. J., Pesce, E., Goh, V., & Montana, G. (2019) · Radiology · doi:10.1148/radiol.2018180921 · Cited by 303 · cited 2×
“Annarumma et al (63) tested such a system to simulate a triage system for retrospective adult chest radio-graphs, resulting in a theoretical reduction in reporting delay for critical studies from 11.2 to 2.7 days.”
BackgroundInfluentialInformation extraction from multi-institutional radiology reports
Hassanpour, S., & Langlotz, C. P. (2016) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2015.09.007 · Cited by 182 · cited 2×
“Machine learning algorithms have been incorporated into the data curation process used to update recommendations within the classification systems, as in the case of TI-RADS (97).”
MethodDeep Learning Based Inter-modality Image Registration Supervised by Intra-modality Similarity
Cao, X., Yang, J., Wang, L., Xue, Z., Wang, Q., & Shen, D. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-00919-9_7 · Cited by 123
Lee, Y. H. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0066-y · Cited by 97 · cited 1×
“For example, Lee (16) automated the selection of routine versus tumor or infection protocols for musculoskeletal MRI, and Trivedi et al (17) distinguished between musculo-skeletal studies with and without gadolinium contrast enhancement.”
Cited by
Redefining Radiology: A Review of Artificial Intelligence Integration in Medical Imaging
Najjar, R. (2023) · Diagnostics · doi:10.3390/diagnostics13172760 · Cited by 886
Artificial intelligence in emergency radiology: A review of applications and possibilities
Katzman, B. D., van der Pol, C. B., Soyer, P., & Patlas, M. N. (2023) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2022.07.005 · Cited by 97
Pierre, K., Haneberg, A. G., Kwak, S., Peters, K. R., Hochhegger, B., Sananmuang, T., Tunlayadechanont, P., Tighe, P. J., Mancuso, A., & Forghani, R. (2023) · Seminars in Roentgenology · doi:10.1053/j.ro.2023.02.003 · Cited by 79
Artificial Intelligence in Emergency Radiology: Where Are We Going?
Cellina, M., Cè, M., Irmici, G., Ascenti, V., Caloro, E., Bianchi, L., Pellegrino, G., D’Amico, N., Papa, S., & Carrafiello, G. (2022) · Diagnostics · doi:10.3390/diagnostics12123223 · Cited by 62
“In their work routine, emergency radiologists must provide an accurate and timely report, leading to meaningful—sometimes critical—decisions, while facing an everyday-increasing workload, and limited time for image interpretation [2]: in this context, where timing and diagnostic accuracy could significantly impact on…”
BackgroundInfluential
Metadata
- Authors
- Tadavarthi, Y., Makeeva, V., Wagstaff, W., Zhan, H., Podlasek, A., Bhatia, N., Heilbrun, M., Krupinski, E., Safdar, N., Banerjee, I., Gichoya, J., & Trivedi, H.
- Venue
- Radiology: Artificial Intelligence
- Published
- 2022-03-01
- Volume
- 4
- Issue
- 2
- Pages
- e210114-e210114
- ISSN
- 2638-6100 (ISSN-L)
- OpenAlex
- W4210630473
- Cited by
- 48
- References
- 13
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.