Oxygen Diffusion Coefficient and Solubility in a New Proton Exchange Membrane
Open accessThe DOI matches its Crossref record.
Abstract
The electrochemical monitoring technique is used to measure the solubility and the diffusion coefficient of oxygen in a new proton exchange membrane that is being developed by Cape Cod Research, Inc. Using the method of least squares, the data were fit to an analytical solution of Fick's second law to determine D and . Values of and were obtained for the diffusion coefficient and solubility, respectively, of the Cape Cod membrane. These values are significantly less than those of Nafion 117 tested under identical conditions. © 2000 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
PEM Fuel cell and electrolysis cell technologies and hydrogen infrastructure development – a review
Wang, Y., Pang, Y., Xu, H., Martinez, A., & Chen, K. S. (2022) · Energy & Environmental Science · doi:10.1039/d2ee00790h · Cited by 828
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2004) · Journal of The Electrochemical Society · doi:10.1149/1.1639157 · Cited by 462
Transport in Polymer-Electrolyte Membranes
Weber, A. Z., & Newman, J. (2003) · Journal of The Electrochemical Society · doi:10.1149/1.1580822 · Cited by 411
Properties of Nafion membranes under PEM water electrolysis conditions
Ito, H., Maeda, T., Nakano, A., & Takenaka, H. (2011) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2011.05.127 · Cited by 393
Characterization of gas crossover and its implications in PEM fuel cells
Kocha, S. S., Deliang Yang, J., & Yi, J. S. (2006) · AIChE Journal · doi:10.1002/aic.10780 · Cited by 362
Pan, M., Pan, C., Li, C., & Zhao, J. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.110771 · Cited by 357
Radical (HO•, H• and HOO•) Formation and Ionomer Degradation in Polymer Electrolyte Fuel Cells
Gubler, L., Dockheer, S. M., & Koppenol, W. H. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3581040 · Cited by 336
Modeling, simulation, and design criteria for photoelectrochemical water-splitting systems
Haussener, S., Xiang, C., Spurgeon, J. M., Ardo, S., Lewis, N. S., & Weber, A. Z. (2012) · Energy & Environmental Science · doi:10.1039/c2ee23187e · Cited by 310
Oxygen Solubility, Diffusion Coefficient, and Solution Viscosity
Xing, W., Yin, M., Lv, Q., Hu, Y., Liu, C., & Zhang, J. (2014) · Rotating Electrode Methods and Oxygen Reduction Electrocatalysts · doi:10.1016/b978-0-444-63278-4.00001-x · Cited by 191
Gas-Crossover and Membrane-Pinhole Effects in Polymer-Electrolyte Fuel Cells
Weber, A. Z. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2898130 · Cited by 122
Zhang, L., Ma, C., & Mukerjee, S. (2003) · Electrochimica Acta · doi:10.1016/s0013-4686(03)00257-3 · Cited by 102
Electrochemical Measurement of the Oxygen Permeation Rate through Polymer Electrolyte Membranes
Zhang, J., Gasteiger, H. A., & Gu, W. (2013) · Journal of The Electrochemical Society · doi:10.1149/2.081306jes · Cited by 35
Metadata
- Authors
- Haug, A. T., & White, R. E.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2000
- Volume
- 147
- Issue
- 3
- Pages
- 980
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2103917509
- Cited by
- 87
- References
- 0
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.