Ionomer Degradation in Polymer Electrolyte Membrane Fuel Cells
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The structural degradation of the polymer electrolyte in both the bulk membrane and the cathode catalyst layer (CL) was investigated. An accelerated stress test (AST) was developed to degrade the ionomer in two membrane electrode assembly (MEA) designs, with cathode catalyst structures comprised of 23 and 33 wt % Nafion, respectively. During the AST the air cathode potential was held at (where RHE is reference hydrogen electrode) at and 100% relative humidity for up to 440 h. The MEA with 33 wt % Nafion had a greater platinum content in the membrane and a higher fluoride washout rate, suggesting the higher ionomer content in the cathode CL facilitated the mass transfer of contaminants (such as dissolved platinum) into the membrane. It is proposed that was produced at the anode, diffused into the membrane, and decomposed at the platinum and iron sites bound in the membrane structure. The decomposition products attacked the ionomer both in the bulk phase and CL, causing ( i ) membrane thinning, which exacerbated the crossover, ( ii ) lower membrane conductivity, and ( iii ) CL structure degradation manifested by enhanced reaction penetration depth into the CL and decreased effective oxygen diffusivity due to the changes in CL water content. These effects acting in synergy had profound negative repercussions on the fuel cell polarization for the MEA with 33 wt % Nafion in the cathode CL.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gasteiger, H. A., Kocha, S. S., Sompalli, B., & Wagner, F. T. (2005) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2004.06.021 · Cited by 4,876
Modeling and Experimental Diagnostics in Polymer Electrolyte Fuel Cells
Springer, T. E., Wilson, M. S., & Gottesfeld, S. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2221120 · Cited by 581
Cited by
Ren, P., Pei, P., Li, Y., Wu, Z., Chen, D., & Huang, S. (2020) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2020.100859 · Cited by 737
Xiao, F., Wang, Y., Wu, Z., Chen, G., Yang, F., Zhu, S., Siddharth, K., Kong, Z., Lu, A., Li, J., et al. (2021) · Advanced Materials · doi:10.1002/adma.202006292 · Cited by 614
Zhao, J., & Li, X. (2019) · Energy Conversion and Management · doi:10.1016/j.enconman.2019.112022 · Cited by 430
Pressurized PEM water electrolysis: Efficiency and gas crossover
Schalenbach, M., Carmo, M., Fritz, D. L., Mergel, J., & Stolten, D. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.09.013 · Cited by 400
Banham, D., Kishimoto, T., Zhou, Y., Sato, T., Bai, K., Ozaki, J.-I., Imashiro, Y., & Ye, S. (2018) · Science Advances · doi:10.1126/sciadv.aar7180 · Cited by 267
Metadata
- Authors
- Young, A. P., Stumper, J., Knights, S., & Gyenge, E.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2010
- Volume
- 157
- Issue
- 3
- Pages
- B425
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2146378374
- Cited by
- 104
- References
- 2
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.