Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 5

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Direct Electrochemistry of Cholesterol Oxidase Immobilized on PEDOT Functionalized Screen-Printed Electrodes

Shi, Rongxiang, Chen, Junhao, Wan, Xiaofang, Tian, Junfei·2023·Journal of The Electrochemical Society

Abstract

To address the problems of high cost and cumbersome preparation process in the current construction of cholesterol biosensors, a third-generation electrochemical cholesterol biosensor with a facile preparation method, low cost, enhanced sensitivity, and wide linear range was investigated in this paper. The cholesterol biosensor was constructed by immobilizing cholesterol oxidase (ChOx) on a poly-3,4-ethylenedioxythiophene (PEDOT) modified screen-printed electrode (SPE). This study showed a very simple fabrication process. The electrodes were constructed only in three steps, including in situ electropolymerization of PEDOT, enzyme introduction and encapsulation of the nafion membrane. The successful modification of PEDOT was demonstrated by Energy Dispersive X-ray spectroscopy (EDX) and Fourier-Transform Infrared spectroscopy (FT-IR). The morphological characterization and electrochemical analysis showed that the presence of PEDOT not only provided more anchoring sites for immobilizing enzymes, but also its high electrocatalytic activity enabled direct electron transfer (DET) between the ChOx and the electrode surface. The linear range for the actual detection of cholesterol was 50–800 μ M, the sensitivity was 1.34 μ A mM −1 , and the electrical signal was not affected by interfering substances such as uric acid, glucose, dopamine, and ascorbic acid. Therefore, the cholesterol biosensor constructed in this paper was expected to achieve large-scale applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/1945-7111/acbac2

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 60

  1. Nakaminami, 1999, Anal. Chem., 71, 1068, 10.1021/ac9805450 · doi:10.1021/ac9805450
  2. Pownall, 2000, JACS, 122, 3985, 10.1021/ja9957128 · doi:10.1021/ja9957128
  3. Aravamudhan, 2007, Biosens. Bioelectron., 22, 2289, 10.1016/j.bios.2006.11.027 · DOI
  4. Fang, 2011, Sensors Actuators B, 155, 545, 10.1016/j.snb.2011.01.005 · doi:10.1016/j.snb.2011.01.005
  5. Narwal, 2019, Steroids, 143, 6, 10.1016/j.steroids.2018.12.003 · DOI · Paper page
  6. Gavarro, 1997, Atherosclerosis, 134, 101, 10.1016/S0021-9150(97)88576-0 · doi:10.1016/s0021-9150(97)88576-0
  7. Xia, 2021, Biosens. Bioelectron., 183, 113243, 10.1016/j.bios.2021.113243 · DOI
  8. Manoj, 2018, Biosens. Bioelectron., 103, 104, 10.1016/j.bios.2017.12.030 · DOI
  9. Murphy, 2021, Colloids Surf., B, 199, 111540, 10.1016/j.colsurfb.2020.111540 · doi:10.1016/j.colsurfb.2020.111540
  10. Theyagarajan, 2019, Scientific Reports, 9, 10428, 10.1038/s41598-019-46982-3 · doi:10.1038/s41598-019-46982-3
  11. Miglione, 2021, Biosensors, 11, 9, 10.3390/bios11090315 · DOI
  12. Chaudhary, 2021, Nanomaterials, 11, 10, 10.3390/nano11102496 · DOI
  13. Umapathi, 2022, ECS Sensors Plus, 1, 044601, 10.1149/2754-2726/ac9d4a · doi:10.1149/2754-2726/ac9d4a
  14. Shen, 2007, Sensors and Actuators B-Chemical, 120, 417, 10.1016/j.snb.2006.02.035 · doi:10.1016/j.snb.2006.02.035
  15. Cinti, 2015, Sensors Actuators B, 221, 187, 10.1016/j.snb.2015.06.054 · DOI
  16. Liu, 2013, Electrochim. Acta, 90, 203, 10.1016/j.electacta.2012.11.119 · DOI
  17. Salazar, 2019, J. Electroanal. Chem., 837, 191, 10.1016/j.jelechem.2019.02.032 · DOI
  18. Saxena, 2011, Biosens. Bioelectron., 26, 3037, 10.1016/j.bios.2010.12.009 · doi:10.1016/j.bios.2010.12.009
  19. Murugan, 2022, ECS Sensors Plus, 1, 034401, 10.1149/2754-2726/ac7c78 · DOI
  20. Li, 2019, J. Nanopart. Res., 21, 162, 10.1007/s11051-019-4602-6 · DOI · Paper page
  21. Moonla, 2017, Electroanalysis, 29, 2698, 10.1002/elan.201700286 · doi:10.1002/elan.201700286
  22. Singh, 2012, Process Biochem., 47, 2189, 10.1016/j.procbio.2012.08.012 · DOI
  23. Abdelwahab, 2010, Electroanalysis, 22, 21, 10.1002/elan.200900363 · DOI
  24. Li, 2015, Sensors Actuators B, 208, 505, 10.1016/j.snb.2014.11.054 · doi:10.1016/j.snb.2014.11.054
  25. Manjunatha, 2010, J. Electroanal. Chem., 651, 24, 10.1016/j.jelechem.2010.11.009 · doi:10.1016/j.jelechem.2010.11.009
  26. Zhu, 2013, Talanta, 106, 192, 10.1016/j.talanta.2012.12.036 · DOI
  27. Shumyantseva, 2005, Biosens. Bioelectron., 21, 217, 10.1016/j.bios.2004.10.008 · DOI
  28. Cao, 2013, Talanta, 109, 167, 10.1016/j.talanta.2013.02.002 · doi:10.1016/j.talanta.2013.02.002
  29. Li, 2011, Electrochim. Acta, 56, 9378, 10.1016/j.electacta.2011.08.020 · doi:10.1016/j.electacta.2011.08.020
  30. Cao, 2013, Biosens. Bioelectron., 42, 532, 10.1016/j.bios.2012.10.048 · doi:10.1016/j.bios.2012.10.048
  31. Dong, 2014, Electrochim. Acta, 132, 465, 10.1016/j.electacta.2014.03.142 · doi:10.1016/j.electacta.2014.03.142
  32. Liu, 2007, Electroanalysis, 19, 55, 10.1002/elan.200603692 · DOI
  33. Agrohiya, 2022, ECS Sensors Plus, 1, 043601, 10.1149/2754-2726/ac973f · doi:10.1149/2754-2726/ac973f
  34. Singh, 2022, ECS Sensors Plus, 1, 023401, 10.1149/2754-2726/ac70e2 · DOI · Paper page
  35. Huang, 2017, Mater. Sci. Eng. C, 77, 1, 10.1016/j.msec.2017.03.253 · doi:10.1016/j.msec.2017.03.253
  36. Wu, 2022, Anal. Chim. Acta, 1221, 340120, 10.1016/j.aca.2022.340120 · DOI
  37. Abdi, 2019, Int. J. Biol. Macromol., 126, 1213, 10.1016/j.ijbiomac.2019.01.001 · DOI
  38. Sharma, 2022, ECS Sensors Plus, 1, 010603, 10.1149/2754-2726/ac612c · DOI
  39. Trivedi, 2009, Sensors Actuators B, 136, 45, 10.1016/j.snb.2008.10.020 · doi:10.1016/j.snb.2008.10.020
  40. Wong, 2022, Pilar taboada sotomayor, J. Electrochem., 52, 1249, 10.1007/s10800-022-01703-z · DOI
  41. Kumar Das, 2022, ECS Sensors Plus, 1, 031601, 10.1149/2754-2726/ac7abb · DOI
  42. El-Sharif, 2022, Anal. Chim. Acta, 1196, 339547, 10.1016/j.aca.2022.339547 · doi:10.1016/j.aca.2022.339547
  43. Somerset, 2010, Int. J. Environ. Anal. Chem., 90, 671, 10.1080/03067310902962536 · doi:10.1080/03067310902962536
  44. Barsan, 2016, Anal. Chim. Acta, 927, 35, 10.1016/j.aca.2016.04.049 · DOI
  45. Chen, 2022, J. Electrochem. Soc., 169, 087502, 10.1149/1945-7111/ac8378 · doi:10.1149/1945-7111/ac8378
  46. Lin, 2022, Talanta, 241, 123187, 10.1016/j.talanta.2021.123187 · DOI · Paper page
  47. Ikeda, 2016, J. Phys. Chem. C, 120, 19043, 10.1021/acs.jpcc.6b07101 · DOI
  48. Li, 2018, Org. Electron., 59, 1, 10.1016/j.orgel.2018.04.03 · doi:10.1016/j.orgel.2018.04.03
  49. Sun, 2021, Angew. Chem. Int. Ed., 60, 5036, 10.1002/anie.201910629 · doi:10.1002/anie.201910629
  50. Kolathodi, 2022, J. Mater. Chem. A, 10, 21124, 10.1039/D2TA04476E · DOI
  51. Wang, 2020, Nat. Commun., 11, 3882, 10.1038/s41467-020-17708-1 · doi:10.1038/s41467-020-17708-1
  52. Baretta, 2023, Sensors Actuators B, 376, 132985, 10.1016/j.snb.2022.132985 · DOI
  53. Dungchai, 2009, Anal. Chem., 81, 5821, 10.1021/ac9007573 · DOI · Paper page
  54. Choi, 2004, Synth. Met., 141, 293, 10.1016/S0379-6779(03)00419-3 · DOI · Paper page
  55. Shin, 2011, Synth. Met., 161, 1284, 10.1016/j.synthmet.2011.04.024 · DOI
  56. Rabti, 2016, Microchim. Acta, 183, 1227, 10.1007/s00604-016-1753-3 · DOI
  57. Gerhardt, 1982, Anal. Chem., 54, 2618, 10.1021/ac00251a054 · doi:10.1021/ac00251a054
  58. Laviron, 1974, J. Electroanal. Chem. Interfacial Electrochem., 52, 355, 10.1016/S0022-0728(74)80448-1 · doi:10.1016/s0022-0728(74)80448-1
  59. Laviron, 1979, J. Electroanal. Chem. Interfacial Electrochem., 101, 19, 10.1016/S0022-0728(79)80075-3 · DOI · Paper page
  60. Scott, 1994, Anal. Chem., 66, 1217, 10.1021/ac00080a004 · doi:10.1021/ac00080a004

Metadata

Authors
Shi, R., Chen, J., Wan, X., & Tian, J.
Venue
Journal of The Electrochemical Society
Published
2023-02-01
Volume
170
Issue
2
Pages
027510
ISSN
  • 0013-4651
  • 1945-7111
Cited by
5
References
1
Licence
Funders
  • National Natural Science Foundation of China (82072016)
  • Fundamental Research Funds for the Central Universities (2020ZYGXZR039)
  • Guangdong Provincial Key Laboratory of Plant Resources Biorefinery (2021GDKLPRB06)
  • Guangdong Basic and Applied Basic Research Foundation (2021A1515011511)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Direct Electrochemistry of Cholesterol Oxidase Immobilized on PEDOT Functionalized Screen-Printed Electrodes. https://app.cochat.ai/papers/10.1149/1945-7111/acbac2
The paper
Shi, R., Chen, J., Wan, X., & Tian, J. (2023). Direct Electrochemistry of Cholesterol Oxidase Immobilized on PEDOT Functionalized Screen-Printed Electrodes. Journal of The Electrochemical Society. https://doi.org/10.1149/1945-7111/acbac2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.