The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
On the Comparative Stability of Li and Na Metal Anode Interfaces in Conventional Alkyl Carbonate Electrolytes
Open accessAbstract
A comparative study of the electrode/electrolyte interface was carried out for lithium and sodium metal anodes in electrolytes consisting in 1 M LiPF 6 in EC 0.5 :DMC 0.5 (LP30) and 1 M NaPF 6 in both EC 0.5 :DMC 0.5 and EC 0.45 PC 0.45 DMC 0.1 . Symmetric Li/Li cells exhibited low polarization and smooth charge discharge curves with current densities of 0.1 and 1 mA/cm 2 . In contrast, large overpotentials were observed even at 0.1 mA/cm 2 for Na/Na cells. Such differences cannot be related to ionic conductivity of the electrolytes but are rather due to an enhanced interfacial resistance (R ct + R SEI ) as deduced from impedance measurements. The composition of the SEI layer was investigated by FTIR and found to be stable for Li electrodes but to evolve upon cycling for Na electrodes which is also in agreement with differences in surface morphology detected by SEM. A lower stability (partial solubility) of the SEI would also enable to understand the differences in the impedance of identical hard carbon (HC) electrodes in cells with either Li or Na counterelectrodes. These results cast some concerns on the reliability of the so termed half cell characterization and call for caution when interpreting the results of potential electrode materials for sodium ion batteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advanced Model for Solid Electrolyte Interphase Electrodes in Liquid and Polymer Electrolytes
Peled, E., Golodnitsky, D., & Ardel, G. (1997) · Journal of The Electrochemical Society · doi:10.1149/1.1837858 · Cited by 1,205
Cited by
Review—SEI: Past, Present and Future
Peled, E., & Menkin, S. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.1441707jes · Cited by 2,182
Fundamentals, status and promise of sodium-based batteries
Usiskin, R., Lu, Y., Popovic, J., Law, M., Balaya, P., Hu, Y.-S., & Maier, J. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00324-w · Cited by 1,370
Sodium Metal Anodes: Emerging Solutions to Dendrite Growth
Lee, B., Paek, E., Mitlin, D., & Lee, S. W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00642 · Cited by 940
Liu, W., Liu, P., & Mitlin, D. (2020) · Advanced Energy Materials · doi:10.1002/aenm.202002297 · Cited by 687
Saurel, D., Orayech, B., Xiao, B., Carriazo, D., Li, X., & Rojo, T. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201703268 · Cited by 668
Metadata
- Authors
- Iermakova, D. I., Dugas, R., Palacín, M. R., & Ponrouch, A.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2015
- Volume
- 162
- Issue
- 13
- Pages
- A7060-A7066
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W1634518569
- Cited by
- 325
- References
- 1
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the Comparative Stability of Li and Na Metal Anode Interfaces in Conventional Alkyl Carbonate Electrolytes. https://app.cochat.ai/papers/10.1149/2.0091513jes
- The paper
- Iermakova, D. I., Dugas, R., Palacín, M. R., & Ponrouch, A. (2015). On the Comparative Stability of Li and Na Metal Anode Interfaces in Conventional Alkyl Carbonate Electrolytes. Journal of The Electrochemical Society. https://doi.org/10.1149/2.0091513jes
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.