Comparative assessments of objective peak-detection algorithms. II. Studies in men
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The performances of eight currently available computerized pulse-detection algorithms were compared on signal-free noise and physiological luteinizing hormone (LH) time series. Signal-free noise was made to vary from 4 to 36% for Gaussian and empirical distributions. Physiological LH data were obtained by immunoassay of blood samples withdrawn every 5 min for 24 h in 8 healthy men, so that the data sets could be emended to simulate varying sampling intensities. Whenever possible, programs were tested at a presumptive 1% false-positive rate. In relation to signal-free noise, the Santen and Bardin program and its modification manifested elevated false-positive rates when the intraseries coefficients of variation increased. The Regional Dual-Threshold program yielded a 1% false-positive rate except on simulated series with high variance. The Cluster and Detect programs both approximated a 1% false-positive rate and the Ultra program approximated a 2.3% false-positive rate throughout the entire range of variance tested. In regard to physiological LH data, all algorithms disclosed a significant impact of sampling intensity on estimates of LH pulse frequency. Sampling-intensity dependent estimates of LH peak frequency by three of the eight programs (Ultra, Cluster, and Detect) were statistically indistinguishable from each other but distinct from the five other programs tested. Furthermore, when judged in relation to their ability to identify individual peaks, the three congruent programs were minimally distinguishable (McNemar's test). Rather, these programs identified the same particular peaks (as defined by concordance of peak maxima) at least 72% of the time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of spontaneous variations of plasma prolactin in normal man
Van Cauter, E., L'Hermite, M., Copinschi, G., Refetoff, S., Desir, D., & Robyn, C. (1981) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1981.241.5.e355 · Cited by 67
Cited by
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“Peakdetection methods provide information on pulse amplitude and location [161]–[164], while spectral/correlation analysis seeks to identify cycles in time series [165], [166].”
Motivations and Methods for Analyzing Pulsatile Hormone Secretion
Veldhuis, J. D., Keenan, D. M., & Pincus, S. M. (2008) · Endocrine Reviews · doi:10.1210/er.2008-0005 · Cited by 223
Self-citationVeldhuis, J. D., & Iranmanesh, A. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-0834 · Cited by 36
Self-citationPLOSKER, S. M., RABINOVICI, J., & JAFFE, R. B. (1991) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-73-3-549 · Cited by 10
Metadata
- Authors
- Urban, R. J., Kaiser, D. L., van Cauter, E., Johnson, M. L., & Veldhuis, J. D.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1988-01-01
- Volume
- 254
- Issue
- 1
- Pages
- E113-E119
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2278881736
- Cited by
- 32
- References
- 1
- FWCI
- 4.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative assessments of objective peak-detection algorithms. II. Studies in men. https://app.cochat.ai/papers/10.1152/ajpendo.1988.254.1.e113
- The paper
- Urban, R. J., Kaiser, D. L., van Cauter, E., Johnson, M. L., & Veldhuis, J. D. (1988). Comparative assessments of objective peak-detection algorithms. II. Studies in men. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.1988.254.1.e113
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.