Placental-fetal glucose exchange and placental glucose consumption in pregnant sheep
Abstract
To determine the separate effects of changes in fetal glucose and insulin concentrations on uteroplacental glucose transfer (UPGT) and consumption (UPGC) we studied 24 late-gestation pregnant sheep during fetal insulin infusions alone and with simultaneous glucose clamp. Insulin infusion alone increased fetal glucose utilization rate (GUR) by 45% (P less than 0.001), decreasing fetal glucose concentration by 40% (P less than 0.01) and thereby increasing fetal glucose clearance (Clglu) by 150% (P less than 0.001). Maternal-fetal glucose gradient also increased, resulting in a 40% increase (P less than 0.02) in UPGT [measured as umbilical glucose uptake (UGU)] and a 30% decrease (P less than 0.05) in UPGC. Addition of a fetal glucose clamp returned fetal glucose concentration to base line and restored UPGC and UGU to control values with a further 2.25-fold increase in fetal GUR. Clglu did not change, as the increase in GUR was proportional to the increase in fetal glucose concentration. Similarly, in animals receiving an insulin infusion plus glucose clamp throughout, maternal glucose concentration, fetal glucose concentration, UPGC, and UGU did not change, whereas GUR and Clglu increased approximately 1.9-fold. These changes were noted at constant maternal glucose concentration and uterine glucose uptake. Thus variation in fetal glucose concentration rather than fetal insulin concentration directly regulates uteroplacental glucose transfer and consumption, whereas both fetal insulin and glucose affect, in separate ways, fetal glucose utilization and clearance.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Even when hyperglycaemia or hypoglycaemia is prolonged in the ewe, placental glucose consumption still varies directly with the maternal glucose concentration.
“Even when hyperglycaemia or hypoglycaemia is prolonged in the ewe, placental glucose consumption still varies directly with the maternal glucose concentration (99, 147).”
From Placental Origins of Chronic Disease (2016) · cites this paper as [147]
Cites
Enhanced Glucose Utilization During Prolonged Glucose Clamp Studies
Doberne, L., Greenfield, M. S., Schulz, B., & Reaven, G. M. (1981) · Diabetes · doi:10.2337/diab.30.10.829 · Cited by 120 · see citing works
Fowden, A. L., & Hay, W. W. (1988) · Quarterly Journal of Experimental Physiology · doi:10.1113/expphysiol.1988.sp003231 · Cited by 66 · see citing works
Self-citationEffects of Insulin and Glucose Concentrations on Glucose Utilization in Fetal Sheep
Hay, W. W., Meznarich, H. K., DiGiacomo, J. E., Hirst, K., & Zerbe, G. O. (1988) · Pediatric Research · doi:10.1203/00006450-198804000-00008 · Cited by 63 · see citing works
Self-citationInsulin Effect on Fetal Glucose Utilization
Simmons, M. A., Jones, M., Battaglia, F. C., et al. (1978) · Pediatric Research · doi:10.1203/00006450-197802000-00004 · Cited by 60 · see citing works
Regulation of Placental Glucose Transfer and Consumption by Fetal Glucose Production
Digiacomo, J. E., & Hay, W. W. (1989) · Pediatric Research · doi:10.1203/00006450-198905000-00001 · Cited by 57 · see citing works
Self-citationEffect of Insulin on Glucose Uptake in Near-Term Fetal Lambs
Hay, W. W., Meznarich, H. K., Sparks, J. W., et al. (1985) · Experimental Biology and Medicine · doi:10.3181/00379727-178-42042 · Cited by 51 · see citing works
Self-citationHay, W. W., & Meznarich, H. K. (1988) · Pediatric Research · doi:10.1203/00006450-198809000-00007 · Cited by 20 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Placental Origins of Chronic Disease
Burton, G. J., Fowden, A. L., & Thornburg, K. L. (2016) · Physiological Reviews · doi:10.1152/physrev.00029.2015 · Cited by 717 · see citing works
- Authors
- DiGiacomo, J. E., & Hay, W. W.
- Affiliations
- University of Colorado Anschutz (US)
- ORCID
- Hay, W. W.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1990-02-01
- Volume
- 258
- Issue
- 2
- Pages
- E360-E367
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2465296339
- Cited by
- 29
- References
- 7
- Citations by year
- 2025: 1 · 2024: 1 · 2018: 4 · 2016: 3 · 2015: 1
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Physiology-Endocrinology and Metabolism (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r01dk035836-09)
- National Institute of Diabetes and Digestive and Kidney Diseases (DK35836)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (HD20761, HD-00781)
- Topics
- Health Sciences › Medicine › Obstetrics and Gynecology › Gestational Diabetes Research and Management
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Birth, Development, and Health
- Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
- Keywords
- fetal insulin, glucose clamp, late pregnancy, pregnant sheep
- MeSH terms
- Animals, Antipyrine, Blood Glucose, Female, Fetal Blood, Fetus, Glucose, Insulin, Kinetics, Maternal-Fetal Exchange, Placenta, Pregnancy, Pregnancy, Animal, Sheep, Uterus, Glucose Clamp Technique
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review