The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Induction of NO and prostaglandin E2in osteoblasts by wall-shear stress but not mechanical strain
Abstract
The nature of the stimulus sensed by bone cells during mechanical usage has not yet been determined. Because nitric oxide (NO) and prostaglandin (PG) production appear to be essential early responses to mechanical stimulation in vivo, we used their production to compare the responsiveness of bone cells to strain and fluid flow in vitro. Cells were incubated on polystyrene film and subjected to unidirectional linear strains in the range 500–5,000 microstrain (με). We found no increase in NO or PGE 2 production after loading of rat calvarial or long bone cells, MC3T3-E1, UMR-106–01, or ROS 17/2.8 cells. In contrast, exposure of osteoblastic cells to increased fluid flow induced both PGE 2 and NO production. Production was rapidly induced by wall-shear stresses of 148 dyn/cm 2 and was observed in all the osteoblastic populations used but not in rat skin fibroblasts. Fluid flow appeared to act through an increase in wall-shear stress. These data suggest that mechanical loading of bone is sensed by osteoblastic cells through fluid flow-mediated wall-shear stress rather than by mechanical strain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review: Bone tissue engineering: The role of interstitial fluid flow
Hillsley, M. V., & Frangos, J. A. (1994) · Biotechnology and Bioengineering · doi:10.1002/bit.260430706 · Cited by 270
Lean, J. M., Mackay, A. G., Chow, J. W., & Chambers, T. J. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.270.6.e937 · Cited by 139
Self-citation
Cited by
Robling, A. G., & Bonewald, L. F. (2020) · Annual Review of Physiology · doi:10.1146/annurev-physiol-021119-034332 · Cited by 539
Mechanosensation and transduction in osteocytes
Klein-Nulend, J., Bakker, A. D., Bacabac, R. G., Vatsa, A., & Weinbaum, S. (2013) · Bone · doi:10.1016/j.bone.2012.10.013 · Cited by 528
Mechanical Strain and Bone Cell Function: A Review
Ehrlich, P. J., & Lanyon, L. E. (2002) · Osteoporosis International · doi:10.1007/s001980200095 · Cited by 512
Sikavitsas, V. I., Bancroft, G. N., & Mikos, A. G. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10150 · Cited by 388
Simmons, C. A., Matlis, S., Thornton, A. J., Chen, S., Wang, C.-Y., & Mooney, D. J. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00110-6 · Cited by 310
Metadata
- Authors
- Smalt, R., Mitchell, F. T., Howard, R. L., & Chambers, T. J.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1997-10-01
- Volume
- 273
- Issue
- 4
- Pages
- E751-E758
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2186696063
- Cited by
- 220
- References
- 2
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Induction of NO and prostaglandin E2in osteoblasts by wall-shear stress but not mechanical strain. https://app.cochat.ai/papers/10.1152/ajpendo.1997.273.4.e751
- The paper
- Smalt, R., Mitchell, F. T., Howard, R. L., & Chambers, T. J. (1997). Induction of NO and prostaglandin E2in osteoblasts by wall-shear stress but not mechanical strain. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.1997.273.4.e751
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.