Hormone pulsatility discrimination via coarse and short time sampling
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Pulsatile hormonal secretion is a ubiquitous finding in endocrinology. However, typical protocols employed to generate data sets suitable for “pulsatility analysis” have required 60–300 samples, rendering such studies largely research methodologies, due primarily to considerable assay expense. One successful mathematical strategy in calibrating changes in pulsatility modalities is approximate entropy (ApEn), a quantification of sequential irregularity. Given the degree of differences between ApEn values in pathophysiological subjects vs. healthy controls reported in several recent studies, we queried to what extent coarser (less frequent) and shorter duration time sampling would still retain significant ApEn differences between clinically distinct cohorts. Accordingly, we reanalyzed data from two studies of 24-h profiles of healthy vs. tumoral hormone secretion: 1) growth hormone comparisons of normal subjects vs. acromegalics, originally sampled every 5 min; and 2) ACTH and cortisol comparisons of normal subjects vs. Cushing's disease patients, originally sampled every 10 min. By multiple statistical analyses, we consistently and highly significantly ( P < 0.0001) established that serum concentration patterns in tumor patients are more irregular than those of controls, with high sensitivity and specificity, even at very coarse (e.g., 60 min) sampling regimens and over relatively short (2–4 h) time intervals. The consistency of these findings suggests a broadly based utility of such shorter and/or coarser sampling methodologies. Substantial reduction in sampling requirements holds the potential to move analysis of pulsatile hormone release from a primarily research tool to a clinically applicable protocol, in appropriate diagnostic and therapeutic contexts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811 · cited 5×
“Recently, a new mathematical approach and formula, approximate entropy (ApEn), have been introduced as a quantification of the regularity of sequential data, motivated both by application needs (9) and by fundamental questions within mathematics (16, 19).”
BackgroundInfluentialSelf-citationGiustina, A., & Veldhuis, J. D. (1998) · Endocrine Reviews · doi:10.1210/edrv.19.6.0353 · Cited by 1,253
Self-citationBrief, Irregular Oscillations of Basal Plasma Insulin and Glucose Concentrations in Diabetic Man
Lang, D. A., Matthews, D. R., Burnett, M., & Turner, R. C. (1981) · Diabetes · doi:10.2337/diab.30.5.435 · Cited by 279
Cited by
Changing complexity in human behavior and physiology through aging and disease
Vaillancourt, D. E., & Newell, K. M. (2002) · Neurobiology of Aging · doi:10.1016/s0197-4580(01)00247-0 · Cited by 551
Alterations in the dynamics of circulating ghrelin, adiponectin, and leptin in human obesity
Yildiz, B. O., Suchard, M. A., Wong, M.-L., McCann, S. M., & Licinio, J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403465101 · Cited by 385
Pathophysiology of hypercortisolism in depression
Carroll, B. J., Cassidy, F., Naftolowitz, D., Tatham, N. E., Wilson, W. H., Iranmanesh, A., Liu, P. Y., & Veldhuis, J. D. (2007) · Acta Psychiatrica Scandinavica · doi:10.1111/j.1600-0447.2007.00967.x · Cited by 317
Juhl, C. B., Hollingdal, M., Sturis, J., Jakobsen, G., Agersø, H., Veldhuis, J., Pørksen, N., & Schmitz, O. (2002) · Diabetes · doi:10.2337/diabetes.51.2.424 · Cited by 264
Self-citationMotivations and Methods for Analyzing Pulsatile Hormone Secretion
Veldhuis, J. D., Keenan, D. M., & Pincus, S. M. (2008) · Endocrine Reviews · doi:10.1210/er.2008-0005 · Cited by 223
Self-citation
Metadata
- Authors
- Pincus, S. M., Hartman, M. L., Roelfsema, F., Thorner, M. O., & Veldhuis, J. D.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1999-11-01
- Volume
- 277
- Issue
- 5
- Pages
- E948-E957
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2181232639
- Cited by
- 130
- References
- 3
- FWCI
- 5.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hormone pulsatility discrimination via coarse and short time sampling. https://app.cochat.ai/papers/10.1152/ajpendo.1999.277.5.e948
- The paper
- Pincus, S. M., Hartman, M. L., Roelfsema, F., Thorner, M. O., & Veldhuis, J. D. (1999). Hormone pulsatility discrimination via coarse and short time sampling. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.1999.277.5.e948
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.