CoChat

Recovery of13CO2during rest and exercise after [1-13C]acetate, [2-13C]acetate, and NaH13CO3infusions

Trimmer, Jeff K., Casazza, Gretchen A., Horning, Michael A., Brooks, George A. · 2001 · American Journal of Physiology-Endocrinology and Metabolism
Cited by 52

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

For estimating the oxidation rates (Rox) of glucose and other substrates by use of 13 C-labeled tracers, we obtained correction factors to account for label dilution in endogenous bicarbonate pools and TCA cycle exchange reactions. Fractional recoveries of 13 C label in respiratory gases were determined during 225 min of rest and 90 min of leg cycle ergometry at 45 and 65% peak oxygen uptake (V˙o 2 peak) after continuous infusions of [1-13 C]acetate, [2-13 C]acetate, or NaH 13 CO 3. In parallel trials, [6,6-2 H]glucose and [1-13 C]glucose were given. Experiments were conducted after an overnight fast with exercise commencing 12 h after the last meal. During the transition from rest to exercise, CO 2 production increased ( P < 0.05) in an intensity-dependent manner. Significant differences were observed in the fractional recoveries of 13 C label as 13 CO 2 at rest (NaH 13 CO 3, 77.5 ± 2.8%; [1-13 C]acetate, 49.8 ± 2.4%; [2-13 C]acetate, 26.1 ± 1.4%). During exercise, fractional recoveries of 13 C label from [1-13 C]acetate, [2-13 C]acetate, and NaH 13 CO 3 were increased compared with rest. Magnitudes of label recoveries during both exercise intensities were tracer specific (NaH 13 CO 3, 93%; [1-13 C]acetate, 80%; [2-13 C]acetate, 65%). Use of an acetate-derived correction factor for estimating glucose oxidation resulted in Rox values in excess ( P< 0.05) of glucose rate of disappearance during hard exercise. We conclude that, after an overnight fast: 1) recovery of 13 C label as 13 CO 2 from [13 C]acetate is decreased compared with bicarbonate; 2) the position of 13 C acetate label affects carbon dilution estimations; 3) recovery of 13 C label increases in the transition from rest to exercise in an isotope-dependent manner; and 4) application of an acetate correction factor in glucose oxidation measurements results in oxidation rates in excess of glucose disappearance during exercise at 65% of V˙o 2 peak. Therefore, bicarbonate, not acetate, correction factors are advocated for estimating glucose oxidation from carbon tracers in exercising men.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpendo.2001.281.4.e683

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 52

Metadata

Authors
Trimmer, J. K., Casazza, G. A., Horning, M. A., & Brooks, G. A.
Venue
American Journal of Physiology-Endocrinology and Metabolism
Published
2001-10-01
Volume
281
Issue
4
Pages
E683-E692
ISSN
  • 0193-1849 (ISSN-L)
  • 1522-1555
OpenAlex
W2106362452
Cited by
52
References
2
FWCI
1.18
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recovery of13CO2during rest and exercise after [1-13C]acetate, [2-13C]acetate, and NaH13CO3infusions. https://app.cochat.ai/papers/10.1152/ajpendo.2001.281.4.e683
The paper
Trimmer, J. K., Casazza, G. A., Horning, M. A., & Brooks, G. A. (2001). Recovery of13CO2during rest and exercise after [1-13C]acetate, [2-13C]acetate, and NaH13CO3infusions. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.2001.281.4.e683

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.