Every slow-wave impulse is associated with motor activity of the human stomach
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Using a newly developed high-resolution three-dimensional magnetic detector system (3D-MAGMA), we observed periodical movements of a small magnetic marker in the human stomach at the typical gastric slow-wave frequency, that is 3 min−1. Thus we hypothesized that each gastric slow wave induces a motor response that is not strong enough to be detected by conventional methods. Electrogastrographies (EGG, Medtronic, Minneapolis, MN) for measurement of gastric slow waves and 3D-MAGMA (Innovent, Jena, Germany) measurements were simultaneously performed in 21 healthy volunteers (10 men, 40.4 ± 13.6 yr; 11 women, 35.8 ± 11.6 yr). The 3D-MAGMA system contains 27 highly sensitive magnetic field sensors that are able to locate a magnetic pill inside a human body with an accuracy of ±5 mm or less in position and ±2° in orientation at a frequency of 50 Hz. Gastric transit time of the magnetic marker ranged from 19 to 154 min. The mean dominant EGG frequency while the marker was in the stomach was 2.87 ± 0.15 cpm. The mean dominant 3D-MAGMA frequency during this interval was nearly identical; that is, 2.85 ± 0.15 movements per minute. We observed a strong linear correlation between individual dominant EGG and 3D-MAGMA frequency ( R = 0.66, P = 0.0011). Our findings suggest that each gastric slow wave induces a minute contraction that is too small to be detected by conventional motility investigations but can be recorded by the 3D-MAGMA system. The present slow-wave theory that assumes that the slow wave is a pure electrical signal should be reconsidered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abrahamsson, H., Antov, S., & Bosaeus, I. (1988) · Scandinavian Journal of Gastroenterology · doi:10.3109/00365528809095938 · Cited by 179 · cited 1×
“Radiopaque markers are used for this purpose (2, 18, 48).”
MethodNamin, F., Patel, J., Lin, Z., Sarosiek, I., Foran, P., Esmaeili, P., & Mccallum, R. (2007) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2006.00867.x · Cited by 129
Cited by
Can dynamic in vitro digestion systems mimic the physiological reality?
Dupont, D., Alric, M., Blanquet-Diot, S., Bornhorst, G., Cueva, C., Deglaire, A., Denis, S., Ferrua, M., Havenaar, R., Lelieveld, J., et al. (2019) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2017.1421900 · Cited by 345
Wolpert, N., Rebollo, I., & Tallon‐Baudry, C. (2020) · Psychophysiology · doi:10.1111/psyp.13599 · Cited by 96
Nandhra, G. K., Chaichanavichkij, P., Birch, M., & Scott, S. M. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12165272 · Cited by 26
“5 g/cm3 Realtime position tracking accuracy: 3 mm N/A Mains-powered system X Strong linear correlation between 3D-MAGMA and Electrogastrography for the measurement of gastric slow waves [30].”
BackgroundMethodInfluential
Metadata
- Authors
- Hocke, M., Schöne, U., Richert, H., Görnert, P., Keller, J., Layer, P., & Stallmach, A.
- Venue
- American Journal of Physiology-Gastrointestinal and Liver Physiology
- Publisher
- American Physiological Society
- Published
- 2009-04
- Volume
- 296
- Issue
- 4
- Pages
- G709-G716
- ISSN
- 0193-1857 (ISSN-L)
- 1522-1547
- OpenAlex
- W2167708320
- Cited by
- 37
- References
- 2
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Every slow-wave impulse is associated with motor activity of the human stomach. https://app.cochat.ai/papers/10.1152/ajpgi.90318.2008
- The paper
- Hocke, M., Schöne, U., Richert, H., Görnert, P., Keller, J., Layer, P., & Stallmach, A. (2009). Every slow-wave impulse is associated with motor activity of the human stomach. American Journal of Physiology-Gastrointestinal and Liver Physiology. https://doi.org/10.1152/ajpgi.90318.2008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.