Validation of a one-dimensional model of the systemic arterial tree
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
A distributed model of the human arterial tree including all main systemic arteries coupled to a heart model is developed. The one-dimensional (1-D) form of the momentum and continuity equations is solved numerically to obtain pressures and flows throughout the systemic arterial tree. Intimal shear is modeled using the Witzig-Womersley theory. A nonlinear viscoelastic constitutive law for the arterial wall is considered. The left ventricle is modeled using the varying elastance model. Distal vessels are terminated with three-element windkessels. Coronaries are modeled assuming a systolic flow impediment proportional to ventricular varying elastance. Arterial dimensions were taken from previous 1-D models and were extended to include a detailed description of cerebral vasculature. Elastic properties were taken from the literature. To validate model predictions, noninvasive measurements of pressure and flow were performed in young volunteers. Flow in large arteries was measured with MRI, cerebral flow with ultrasound Doppler, and pressure with tonometry. The resulting 1-D model is the most complete, because it encompasses all major segments of the arterial tree, accounts for ventricular-vascular interaction, and includes an improved description of shear stress and wall viscoelasticity. Model predictions at different arterial locations compared well with measured flow and pressure waves at the same anatomical points, reflecting the agreement in the general characteristics of the “generic 1-D model” and the “average subject” of our volunteer population. The study constitutes a first validation of the complete 1-D model using human pressure and flow data and supports the applicability of the 1-D model in the human circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald, D. A. (1963) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196301000-00017 · Cited by 1,565
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Aortic input impedance in normal man: relationship to pressure wave forms.
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980) · Circulation · doi:10.1161/01.cir.62.1.105 · Cited by 1,014
The dynamic elastic properties of the arterial wall
Bergel, D. H. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006687 · Cited by 904
Olufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862
Dodge, J. T., Brown, B. G., Bolson, E. L., & Dodge, H. T. (1992) · Circulation · doi:10.1161/01.cir.86.1.232 · Cited by 792
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684 · cited 2×
“Table 1 for review) for simulating wave propagation in the entire (2, 13) or parts of the arterial tree (6, 48, 50, 69) under various physiological (44, 50, 55, 70, 74) or pathological conditions (1, 3, 9, 36, 64, 71).”
BackgroundMethodCardiac Contraction and the Pressure-Volume Relationship
SAGAWA, K. (1988) · Cited by 648
Multi-branched model of the human arterial system
Avolio, A. P. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441895 · Cited by 517
Computer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511
Self-citationOne-dimensional modelling of a vascular network in space-time variables
Sherwin, S. J., Franke, V., Peiró, J., & Parker, K. (2003) · Journal of Engineering Mathematics · doi:10.1023/b:engi.0000007979.32871.e2 · Cited by 464
Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 454
Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.05.041 · Cited by 441
Structured tree outflow condition for blood flow in larger systemic arteries
Olufsen, M. S. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.1.h257 · Cited by 439
Alastruey, J., Parker, K. H., Peiró, J., Byrd, S. M., & Sherwin, S. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.07.008 · Cited by 436
Senzaki, H., Chen, C.-H., & Kass, D. A. (1996) · Circulation · doi:10.1161/01.cir.94.10.2497 · Cited by 383
Effects of age on ventricular-vascular coupling
Nichols, W. W., O'Rourke, M. F., Avolio, A. P., Yaginuma, T., Murgo, J. P., Pepine, C. J., & Conti, C. R. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90659-9 · Cited by 346
Characterization of common carotid artery blood-flow waveforms in normal human subjects
Holdsworth, D. W., Norley, C. J. D., Frayne, R., Steinman, D. A., & Rutt, B. K. (1999) · Physiological Measurement · doi:10.1088/0967-3334/20/3/301 · Cited by 338
Evaluation of methods for estimation of total arterial compliance
Stergiopulos, N., Meister, J. J., & Westerhof, N. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.268.4.h1540 · Cited by 267
Self-citationMatthys, K. S., Alastruey, J., Peiró, J., Khir, A. W., Segers, P., Verdonck, P. R., Parker, K. H., & Sherwin, S. J. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.05.027 · Cited by 255
Buijs, P. C., Krabbe-Hartkamp, M. J., Bakker, C. J., de Lange, E. E., Ramos, L. M., Breteler, M. M., & Mali, W. P. (1998) · Radiology · doi:10.1148/radiology.209.3.9844657 · Cited by 221
Use of pulse pressure method for estimating total arterial compliance in vivo
Stergiopulos, N., Segers, P., & Westerhof, N. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.2.h424 · Cited by 211
Self-citationColor Duplex Measurement of Cerebral Blood Flow Volume in Healthy Adults
Scheel, P., Ruge, C., Petruch, U. R., & Schöning, M. (2000) · Stroke · doi:10.1161/01.str.31.1.147 · Cited by 209
Numerical modeling of 1D arterial networks coupled with a lumped parameters description of the heart
Formaggia, L., Lamponi, D., Tuveri, M., & Veneziani, A. (2006) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840600857767 · Cited by 205
Bessems, D. D., Rutten, M. C. M., & van de Vosse, F. N. (2007) · Journal of Fluid Mechanics · doi:10.1017/s0022112007005344 · Cited by 185
Stergiopulos, N., Meister, J. J., & Westerhof, N. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368245 · Cited by 173
Self-citationMagnetic resonance imaging of coronary arteries: technique and preliminary results.
Pennell, D. J., Keegan, J., Firmin, D. N., Gatehouse, P. D., Underwood, S. R., & Longmore, D. B. (1993) · Heart · doi:10.1136/hrt.70.4.315 · Cited by 171
Spilt, A., Box, F. M. A., van der Geest, R. J., Reiber, J. H. C., Kunz, P., Kamper, A. M., Blauw, G. J., & van Buchem, M. A. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10133 · Cited by 158
Wan, J., Steele, B. N., Spicer, S. A., Strohband, S., Feijóo, G. R., Hughes, T. J. R., & Taylor, C. A. (2002) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840290010670 · Cited by 154
Normal Size of the Internal Carotid, Middle Cerebral and Anterior Cerebral Arteries
Gabrielsen, T. O., & Greitz, T. V. B. (1970) · Acta Radiologica Diagnosis · doi:10.1177/028418517001000101 · Cited by 145
A computer simulation of arterial dynamics in the human leg
Raines, J. K., Jaffrin, M. Y., & Shapiro, A. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90072-4 · Cited by 132
The use of an analog computer in a circulation model
Noordergraaf, A., Verdouw, P. D., & Boom, H. B. K. (1963) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(63)80009-2 · Cited by 115
Cassot, F., Vergeur, V., Bossuet, P., Hillen, B., Zagzoule, M., & Marc-Vergnes, J. P. (1995) · Circulation · doi:10.1161/01.cir.92.10.3122 · Cited by 112
A global mathematical model of the cerebral circulation in man
Zagzoule, M., & Marc-Vergnes, J. P. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90118-1 · Cited by 111
Digital computer simulation of human systemic arterial pulse wave transmission: A nonlinear model
Schaaf, B. W., & Abbrecht, P. H. (1972) · Journal of Biomechanics · doi:10.1016/0021-9290(72)90064-4 · Cited by 108
Stettler, J. C., Niederer, P., & Anliker, M. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02363533 · Cited by 107
Huo, Y., & Kassab, G. S. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00987.2006 · Cited by 101
Segers, P., Rietzschel, E. R., Heireman, S., DEBUYZERE, M., Gillebert, T. C., Verdonck, P., & VANBORTEL, L. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.04.005 · Cited by 94
Mechanical properties of human cerebral arteries.
Hayashi, K., Nagasawa, S., Naruo, Y., Okumura, A., Moritake, K., & Handa, H. (1980) · PubMed · Cited by 91
Hemodynamics induced after acute reduction of proximal thoracic aorta compliance
Ioannou, C. V., Stergiopulos, N., Katsamouris, A. N., Startchik, I., Kalangos, A., Licker, M. J., Westerhof, N., & Morel, D. R. (2003) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.2002.1917 · Cited by 86
Self-citationA Viscoelastic Model for Use in Predicting Arterial Pulse Waves
Holenstein, R., Niederer, P. F., & Anliker, M. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138229 · Cited by 78
Physical basis of pressure transfer from periphery to aorta: a model-based study
Stergiopulos, N., Westerhof, B. E., & Westerhof, N. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.4.h1386 · Cited by 77
Self-citationCassot, F., Zagzoule, M., & Marc-Vergnes, J. P. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00193-1 · Cited by 67
A Circle of Willis Simulation Using Distensible Vessels and Pulsatile Flow
Kufahl, R., & Clark, M. E. (1985) · Journal of Biomechanical Engineering · doi:10.1115/1.3138531 · Cited by 62
Assessment of distributed arterial network models
Segers, P., Stergiopulos, N., Verdonck, P. R., & Verhoeven, R. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02510985 · Cited by 58
Self-citationInstantaneous Pressure Distribution Along the Human Aorta
Luchsinger, P. C., Snell, R. E., Patel, D. J., & Fry, D. L. (1964) · Circulation Research · doi:10.1161/01.res.15.6.503 · Cited by 53
Physical basis of ballistocardiography. III
Bürger, H., & Noordergraaf, A. (1956) · American Heart Journal · doi:10.1016/0002-8703(56)90079-5 · Cited by 45
The area ratio of normal arterial junctions and its implications in pulse wave reflections
Papageorgiou, G. L., Jones, B. N., Redding, V. J., & Hudson, N. (1990) · Cardiovascular Research · doi:10.1093/cvr/24.6.478 · Cited by 39
Stettler, J. C., Niederer, P., Anliker, M., & Casty, M. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02363534 · Cited by 35
LV-arterial coupling: interactive model to predict effect of wave reflections on LV energetics
FITCHETT, D. H. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.261.4.h1026 · Cited by 34
Scatter in input impedance spectrum may result from the elastic nonlinearity of the arterial wall
Stergiopulos, N., Meister, J. ‐., & Westerhof, N. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.4.h1490 · Cited by 18
Self-citationObata, T., Shishido, F., Koga, M., Ikehira, H., Kimura, F., & Yoshida, K. (1996) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(96)00228-7 · Cited by 15
Cited by
Kissas, G., Yang, Y., Hwuang, E., Witschey, W. R., Detre, J. A., & Perdikaris, P. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.112623 · Cited by 647
Rasmussen, M. K., Mestre, H., & Nedergaard, M. (2022) · Physiological Reviews · doi:10.1152/physrev.00031.2020 · Cited by 597
Alastruey, J., Khir, A. W., Matthys, K. S., Segers, P., Sherwin, S. J., Verdonck, P. R., Parker, K. H., & Peiró, J. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.05.041 · Cited by 441
Review of Zero-D and 1-D Models of Blood Flow in the Cardiovascular System
Shi, Y., Lawford, P., & Hose, R. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-33 · Cited by 399
Pulse Wave Propagation in the Arterial Tree
van de Vosse, F. N., & Stergiopulos, N. (2011) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122109-160730 · Cited by 387
Self-citation
Metadata
- Authors
- Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2009-07
- Volume
- 297
- Issue
- 1
- Pages
- H208-H222
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2148232499
- Cited by
- 638
- References
- 53
- FWCI
- 17.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.