The DOI matches its Crossref record.
Effects of elastin haploinsufficiency on the mechanical behavior of mouse arteries
Abstract
Supravalvular aortic stenosis (SVAS) is associated with decreased elastin and altered arterial mechanics. Mice with a single deletion in the elastin gene (ELN+/−) are models for SVAS. Previous studies have shown that elastin haploinsufficiency in these mice causes hypertension, decreased arterial compliance, and changes in arterial wall structure. Despite these differences, ELN+/− mice have a normal life span, suggesting that the arteries remodel and adapt to the decreased amount of elastin. To test this hypothesis, we performed in vitro mechanical tests on abdominal aorta, ascending aorta, and left common carotid artery from ELN+/− and wild-type (C57BL/6J) mice. We compared the circumferential and longitudinal stress-stretch relationships and residual strains. The circumferential stress-stretch relationship is similar between genotypes and changes <3% with longitudinal stretch at lengths within 10% of the in vivo value. At mean arterial pressure, the circumferential stress in the ascending aorta is higher in ELN+/− than in wild type. Although arterial pressures are higher, the increased number of elastic lamellae in ELN+/− arteries results in similar tension/lamellae compared with wild type. The longitudinal stress-stretch relationship is similar between genotypes for most arteries. Compared with wild type, the in vivo longitudinal stretch is lower in ELN+/− abdominal and carotid arteries and the circumferential residual strain is higher in ELN+/− ascending aorta. The increased circumferential residual strain brings the transmural strain distribution in ELN+/− ascending aorta close to wild-type values. The mechanical behavior of ELN+/− arteries is likely due to the reduced elastin content combined with adaptive remodeling during vascular development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Twisted Blood Vessels: Symptoms, Etiology and Biomechanical Mechanisms
Han, H.-C. (2012) · Journal of Vascular Research · doi:10.1159/000335123 · Cited by 489
Elastin in Large Artery Stiffness and Hypertension
Wagenseil, J. E., & Mecham, R. P. (2012) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-012-9349-8 · Cited by 462
Self-citationAge-related vascular stiffening: causes and consequences
Kohn, J. C., Lampi, M. C., & Reinhart-King, C. A. (2015) · Frontiers in Genetics · doi:10.3389/fgene.2015.00112 · Cited by 440
New insights into elastic fiber assembly
Wagenseil, J. E., & Mecham, R. P. (2007) · Birth Defects Research Part C: Embryo Today: Reviews · doi:10.1002/bdrc.20111 · Cited by 420
Self-citationLim, H. Y., Lim, S. Y., Tan, C. K., Thiam, C. H., Goh, C. C., Carbajo, D., Chew, S. H. S., See, P., Chakarov, S., Wang, X. N., et al. (2018) · Immunity · doi:10.1016/j.immuni.2018.06.008 · Cited by 384
Metadata
- Authors
- Wagenseil, J. E., Nerurkar, N. L., Knutsen, R. H., Okamoto, R. J., Li, D. Y., & Mecham, R. P.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-09
- Volume
- 289
- Issue
- 3
- Pages
- H1209-H1217
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2143286808
- Cited by
- 187
- References
- 0
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of elastin haploinsufficiency on the mechanical behavior of mouse arteries. https://app.cochat.ai/papers/10.1152/ajpheart.00046.2005
- The paper
- Wagenseil, J. E., Nerurkar, N. L., Knutsen, R. H., Okamoto, R. J., Li, D. Y., & Mecham, R. P. (2005). Effects of elastin haploinsufficiency on the mechanical behavior of mouse arteries. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00046.2005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.