The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Flow-mediated dilation in human brachial artery after different circulatory occlusion conditions
Open accessAbstract
Different magnitudes and durations of postocclusion reactive hyperemia were achieved by occluding different volumes of tissue with and without ischemic exercise to test the hypotheses that flow-mediated dilation (FMD) of the brachial artery would depend on the increase in peak flow rate or shear stress and that the position of the occlusion cuff would affect the response. The brachial artery FMD response was observed by high-frequency ultrasound imaging with curve fitting to minimize the effects of random measurement error in eight healthy, young, nonsmoking men. Reactive hyperemia was graded by 5-min occlusion distal to the measurement site at the wrist and the forearm and proximal to the site in the upper arm. Flow was further increased by exercise during occlusion at the wrist and forearm positions. For the two wrist occlusion conditions, flow increased eightfold and FMD was only 1 to 2% ( P > 0.05). After the forearm and upper arm occlusions, blood flow was almost identical but FMD after forearm occlusions was 3.4% ( P < 0.05), whereas it was significantly greater (6.6%, P < 0.05) and more prolonged after proximal occlusion. Forearm occlusion plus exercise caused a greater and more prolonged increase in blood flow, yet FMD (7.0%) was qualitatively and quantitatively similar to that after proximal occlusion. Overall, the magnitude of FMD was significantly correlated with peak forearm blood flow ( r = 0.59, P < 0.001), peak shear rate ( r = 0.49, P < 0.002), and total 5-min reactive hyperemia ( r = 0.52, P < 0.001). The prolonged FMD after upper arm occlusion suggests that the mechanism for FMD differs with occlusion cuff position.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Postischemic vasodilation in human forearm is dependent on endothelium-derived nitric oxide
Meredith, I. T., Currie, K. E., Anderson, T. J., Roddy, M. A., Ganz, P., & Creager, M. A. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.270.4.h1435 · Cited by 281
Measurement of endothelial function by brachial artery flow-mediated vasodilation
Vogel, R. A. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01764-7 · Cited by 133
Cited by
Ultrasound Assessment of Flow-Mediated Dilation
Harris, R. A., Nishiyama, S. K., Wray, D. W., & Richardson, R. S. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.150821 · Cited by 667
Pyke, K. E., & Tschakovsky, M. E. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.089755 · Cited by 614
Shear Stress Mediates Endothelial Adaptations to Exercise Training in Humans
Tinken, T. M., Thijssen, D. H. J., Hopkins, N., Dawson, E. A., Cable, N. T., & Green, D. J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.146282 · Cited by 493
Endothelial dysfunction and cardiovascular disease
Jay Widmer, R., & Lerman, A. (2014) · Global Cardiology Science and Practice · doi:10.5339/gcsp.2014.43 · Cited by 356
Metadata
- Authors
- Betik, A. C., Luckham, V. B., & Hughson, R. L.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2004-01
- Volume
- 286
- Issue
- 1
- Pages
- H442-H448
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2056266218
- Cited by
- 173
- References
- 4
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow-mediated dilation in human brachial artery after different circulatory occlusion conditions. https://app.cochat.ai/papers/10.1152/ajpheart.00314.2003
- The paper
- Betik, A. C., Luckham, V. B., & Hughson, R. L. (2004). Flow-mediated dilation in human brachial artery after different circulatory occlusion conditions. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00314.2003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.