Structural morphology of renal vasculature
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
An automatic segmentation technique has been developed and applied to two renal micro-computer tomography (CT) images. With the use of a 20-μm voxel resolution image, the arterial and venous trees were segmented for the rat renal vasculature, distinguishing resolving vessels down to 30 μm in radius. A higher resolution 4-μm voxel image of a renal vascular subtree, with vessel radial values down to 10 μm, was segmented. Strahler ordering was applied to each subtree using an iterative scheme developed to integrate information from the two segmented models to reconstruct the complete topology of the entire vascular tree. An error analysis of the assigned orders quantified the robustness of the ordering process for the full model. Radial, length, and connectivity data of the complete arterial and venous trees are reported by order. Substantial parallelism is observed between individual arteries and veins, and the ratio of parallel vessel radii is quantified via a power law. A strong correlation with Murray's Law was established, providing convincing evidence of the “minimum work” hypothesis. Results were compared with theoretical branch angle formulations, based on the principles of “minimum shear force,” were inconclusive. Three-dimensional reconstructions of renal vascular trees collected are made freely available 1 1 http://www.physiome.org.nz/publications/nordsletten_blackett_ritman_bentley_smith_2005 . for further investigation into renal physiology and modeling studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weibel, E. R. (1963) · Springer eBooks · doi:10.1007/978-3-642-87553-3 · Cited by 3,353
The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume
Murray, C. D. (1926) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.12.3.207 · Cited by 2,087 · cited 9×
“Furthermore, this adds additional support of the minimum work hypothesis (31).”
BackgroundInfluentialHuman cardiovascular adjustments to exercise and thermal stress.
Rowell, L. B. (1974) · Physiological Reviews · doi:10.1152/physrev.1974.54.1.75 · Cited by 1,675 · cited 1×
“Thermoregulation has been seen as an explanation for parallelism, occurring primarily in arteries and veins in the same sheath (35).”
BackgroundHYPSOMETRIC (AREA-ALTITUDE) ANALYSIS OF EROSIONAL TOPOGRAPHY
STRAHLER, A. N. (1952) · Geological Society of America Bulletin · doi:10.1130/0016-7606(1952)63[1117:haaoet]2.0.co;2 · Cited by 1,633
Gottschalk, C. W., & Mylle, M. (1959) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1959.196.4.927 · Cited by 587 · cited 1×
““Cross talk” or the so-called “counter-current exchange” hypothesis has been demonstrated in renal vasa recta and tubules (13) as well as in villi of the small intestine (14).”
BackgroundMorphometry of pig coronary arterial trees
Kassab, G. S., Rider, C. A., Tang, N. J., & Fung, Y. C. (1993) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1993.265.1.h350 · Cited by 400 · cited 2×
“(20, 21) presented the idea of the connectivity matrix (CM).”
BackgroundAn Anatomically Based Model of Transient Coronary Blood Flow in the Heart
Smith, N. P., Pullan, A. J., & Hunter, P. J. (2002) · SIAM Journal on Applied Mathematics · doi:10.1137/s0036139999355199 · Cited by 339 · cited 1×
“Models such as Poiseuille flow (49), lumped parameter models (30), and more complex models such as one-dimensional fluid flow through passive distensible vessel networks (39) have been proposed.”
BackgroundSelf-citationA standard nomenclature for structures of the kidney
(1988) · Kidney International · doi:10.1038/ki.1988.1 · Cited by 283
Morphometry of the Human Pulmonary Arterial Tree
SINGHAL, S., Henderson, R. A., Horsfield, K., Harding, K. G., & CUMMING, G. (1973) · Circulation Research · doi:10.1161/01.res.33.2.190 · Cited by 252
Barger, A. C., & Herd, J. A. (1971) · New England Journal of Medicine · doi:10.1056/nejm197103042840907 · Cited by 226
Cited by
Intrarenal oxygenation: unique challenges and the biophysical basis of homeostasis
Evans, R. G., Gardiner, B. S., Smith, D. W., & O'Connor, P. M. (2008) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.90230.2008 · Cited by 274
“It is driven by the AV PO2 difference and facilitated by the close anatomical association of arteries and veins, as occurs most strikingly in the kidney (31, 32, 80, 84).”
BackgroundCurrent Status of Developments and Applications of Micro-CT
Ritman, E. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124717 · Cited by 243
Self-citationTowards organ printing: engineering an intra-organ branched vascular tree
Visconti, R. P., Kasyanov, V., Gentile, C., Zhang, J., Markwald, R. R., & Mironov, V. (2010) · Expert Opinion on Biological Therapy · doi:10.1517/14712590903563352 · Cited by 224
“The complexity of branching pattern of the intraorgan vascular tree is illustrated by this view of the kidney vasculature [30].”
BackgroundThe role of declining adaptive homeostasis in ageing
Pomatto, L. C. D., & Davies, K. J. A. (2017) · The Journal of Physiology · doi:10.1113/jp275072 · Cited by 216
“In consequence, many of these areas are potential weak points and common areas of plaque buildup (Nordsletten et al. 2006).”
BackgroundExpansion of the fetoplacental vasculature in late gestation is strain dependent in mice
Rennie, M. Y., Detmar, J., Whiteley, K. J., Jurisicova, A., Adamson, S. L., & Sled, J. G. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00776.2011 · Cited by 57
Steinman, J., Cahill, L. S., Koletar, M. M., Stefanovic, B., & Sled, J. G. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116101 · Cited by 24
Metadata
- Authors
- Nordsletten, D. A., Blackett, S., Bentley, M. D., Ritman, E. L., & Smith, N. P.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2006-07
- Volume
- 291
- Issue
- 1
- Pages
- H296-H309
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1984058294
- Cited by
- 159
- References
- 32
- FWCI
- 12.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.