CoChat

Does arterial shear explain the magnitude of flow-mediated dilation?: a comparison between young and older humans

Open access
Thijssen, Dick H. J., Bullens, Lauren M., van Bemmel, Marieke M., Dawson, Ellen A., Hopkins, Nicola, Tinken, Toni M., Black, Mark A., Hopman, Maria T. E., Cable, N. Timothy, Green, Daniel J. · 2009 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 117

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Flow-mediated dilatation (FMD) has become a commonly applied approach for the assessment of vascular function and health in humans. Recent studies emphasize the importance of normalizing the magnitude of FMD to its apparent eliciting stimulus, the postdeflation arterial shear. However, the relationship between shear stress and the magnitude of FMD may differ between groups. The aim of this study was to examine the relationship between the brachial FMD and four different indexes of postdeflation shear rate (SR) in healthy children ( n = 51, 10 ± 1 yr) and young ( n = 57, 27 ± 6 yr) and older ( n = 27, 58 ± 4 yr) adults. SR was calculated from deflation ( time 0) until 9 s (peak), 30 s (0–30), 60 s (0–60), or until the time-to-peak diameter in each individual (0-ttp). Edge detection and wall tracking of high resolution B-mode arterial ultrasound images were used to calculate the conduit artery diameter. In young adults, the brachial artery FMD demonstrated a significant correlation with the area under the SR curve (SR AUC) 0–30 s ( r 2 = 0.12, P = 0.009), 0–60 s ( r 2 = 0.14, P = 0.005), and 0-ttp ( r 2 = 0.14, P = 0.005) but not for the peak SR AUC 0–9 s ( r 2 = 0.04, P = 0.12). In children and older adults, the magnitude of the brachial artery FMD did not correlate with any of the four SR AUC stimuli. These findings suggest that in young subjects, postdeflation SR AUC correlates moderately with the magnitude of the FMD response. However, the relationship between FMD and postdeflation shear appears to be age dependent, with less evidence for an association in younger and older subjects. Therefore, we support presenting SR AUC stimuli but not normalizing FMD responses for the SR AUC when using this technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00980.2008

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 117

Metadata

Authors
Thijssen, D. H. J., Bullens, L. M., van Bemmel, M. M., Dawson, E. A., Hopkins, N., Tinken, T. M., Black, M. A., Hopman, M. T. E., Cable, N. T., & Green, D. J.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2009-01
Volume
296
Issue
1
Pages
H57-H64
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2000001154
Cited by
117
References
4
FWCI
8.36
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Does arterial shear explain the magnitude of flow-mediated dilation?: a comparison between young and older humans. https://app.cochat.ai/papers/10.1152/ajpheart.00980.2008
The paper
Thijssen, D. H. J., Bullens, L. M., van Bemmel, M. M., Dawson, E. A., Hopkins, N., Tinken, T. M., Black, M. A., Hopman, M. T. E., Cable, N. T., & Green, D. J. (2009). Does arterial shear explain the magnitude of flow-mediated dilation?: a comparison between young and older humans. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00980.2008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.