The DOI matches its Crossref record.
Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries
Abstract
Restenosis resulting from neointimal hyperplasia (NH) limits the effectiveness of intravascular stents. Rates of restenosis vary with stent geometry, but whether stents affect spatial and temporal distributions of wall shear stress (WSS) in vivo is unknown. We tested the hypothesis that alterations in spatial WSS after stent implantation predict sites of NH in rabbit iliac arteries. Antegrade iliac artery stent implantation was performed under angiography, and blood flow was measured before casting 14 or 21 days after implantation. Iliac artery blood flow domains were obtained from three-dimensional microfocal X-ray computed tomography imaging and reconstruction of the arterial casts. Indexes of WSS were determined using three-dimensional computational fluid dynamics. Vascular histology was unchanged proximal and distal to the stent. Time-dependent NH was localized within the stented region and was greatest in regions exposed to low WSS and acute elevations in spatial WSS gradients. The lowest values of WSS spatially localized to the stented area of a theoretical artery progressively increased after 14 and 21 days as NH occurred within these regions. This NH abolished spatial disparity in distributions of WSS. The results suggest that stents may introduce spatial alterations in WSS that modulate NH in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computational fluid dynamics modelling in cardiovascular medicine
Morris, P. D., Narracott, A., von Tengg-Kobligk, H., Silva Soto, D. A., Hsiao, S., Lungu, A., Evans, P., Bressloff, N. W., Lawford, P. V., Hose, D. R., et al. (2016) · Heart · doi:10.1136/heartjnl-2015-308044 · Cited by 495
Patient-Specific Modeling of Cardiovascular Mechanics
Taylor, C. A., & Figueroa, C. A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160521 · Cited by 451
Role of Endothelial Shear Stress in Stent Restenosis and Thrombosis
Koskinas, K. C., Chatzizisis, Y. S., Antoniadis, A. P., & Giannoglou, G. D. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.10.903 · Cited by 347
Assessment of vascular wall shear stress and implications for atherosclerotic disease
Papaioannou, T. G., Karatzis, E. N., Vavuranakis, M., Lekakis, J. P., & Stefanadis, C. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.03.035 · Cited by 126
Metadata
- Authors
- LaDisa, J. F., Olson, L. E., Molthen, R. C., Hettrick, D. A., Pratt, P. F., Hardel, M. D., Kersten, J. R., Warltier, D. C., & Pagel, P. S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-05
- Volume
- 288
- Issue
- 5
- Pages
- H2465-H2475
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2041119324
- Cited by
- 185
- References
- 0
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries. https://app.cochat.ai/papers/10.1152/ajpheart.01107.2004
- The paper
- LaDisa, J. F., Olson, L. E., Molthen, R. C., Hettrick, D. A., Pratt, P. F., Hardel, M. D., Kersten, J. R., Warltier, D. C., & Pagel, P. S. (2005). Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.01107.2004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.