Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Restenosis resulting from neointimal hyperplasia (NH) limits the effectiveness of intravascular stents. Rates of restenosis vary with stent geometry, but whether stents affect spatial and temporal distributions of wall shear stress (WSS) in vivo is unknown. We tested the hypothesis that alterations in spatial WSS after stent implantation predict sites of NH in rabbit iliac arteries. Antegrade iliac artery stent implantation was performed under angiography, and blood flow was measured before casting 14 or 21 days after implantation. Iliac artery blood flow domains were obtained from three-dimensional microfocal X-ray computed tomography imaging and reconstruction of the arterial casts. Indexes of WSS were determined using three-dimensional computational fluid dynamics. Vascular histology was unchanged proximal and distal to the stent. Time-dependent NH was localized within the stented region and was greatest in regions exposed to low WSS and acute elevations in spatial WSS gradients. The lowest values of WSS spatially localized to the stented area of a theoretical artery progressively increased after 14 and 21 days as NH occurred within these regions. This NH abolished spatial disparity in distributions of WSS. The results suggest that stents may introduce spatial alterations in WSS that modulate NH in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319 · cited 1×
“Geometrically accurate reconstruction volumes were generated using the Feldcamp cone-beam reconstruction algorithm (7).”
MethodFischman, D. L., Leon, M. B., Baim, D. S., Schatz, R. A., Savage, M. P., Penn, I., Detre, K., Veltri, L., Ricci, D., Nobuyoshi, M., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310802 · Cited by 4,271 · cited 2×
“The rigid framework of the stent causes differences in compliance between the stented and native regions of the artery, but this stent rigidity provides structural scaffolding that is associated with reduced restenosis rates compared with angioplasty alone (4, 8).”
BackgroundMorice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707 · cited 1×
“Previous studies have suggested that there may be a correlation between stent-induced alterations in WSS and neointimal hyperplasia during pathological processes including primary atherogenesis and restenosis after angioplasty (17, 18, 20, 21, 30).”
BackgroundMcDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Introduction to fluid mechanics
(2013) · Engineering Science · doi:10.4324/9780203114964-25 · Cited by 1,957
Ku, D. N. (1997) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.29.1.399 · Cited by 1,477
Pathology of Acute and Chronic Coronary Stenting in Humans
Farb, A., Sangiorgi, G., Carter, A. J., Walley, V. M., Edwards, W. D., Schwartz, R. S., & Virmani, R. (1999) · Circulation · doi:10.1161/01.cir.99.1.44 · Cited by 871 · cited 1×
“stent implantation is located in regions where the stent lies in apposition to the intima (5, 6), suggesting that the present histological results from normal rabbit iliac arteries also differ from human lesions, which are typically eccentric in shape and place the stent in only partial contact with the calcified athe…”
BackgroundKornowski, R., Hong, M. K., Tio, F. O., Bramwell, O., Wu, H., & Leon, M. B. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00450-6 · Cited by 844
Inflammation and Restenosis in the Stent Era
Welt, F. G. P., & Rogers, C. (2002) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000037100.44766.5b · Cited by 628
Cited by
Computational fluid dynamics modelling in cardiovascular medicine
Morris, P. D., Narracott, A., von Tengg-Kobligk, H., Silva Soto, D. A., Hsiao, S., Lungu, A., Evans, P., Bressloff, N. W., Lawford, P. V., Hose, D. R., et al. (2016) · Heart · doi:10.1136/heartjnl-2015-308044 · Cited by 495
Patient-Specific Modeling of Cardiovascular Mechanics
Taylor, C. A., & Figueroa, C. A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160521 · Cited by 451
Role of Endothelial Shear Stress in Stent Restenosis and Thrombosis
Koskinas, K. C., Chatzizisis, Y. S., Antoniadis, A. P., & Giannoglou, G. D. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.10.903 · Cited by 347
Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases
Son, D., Lee, J., Lee, D. J., Ghaffari, R., Yun, S., Kim, S. J., Lee, J. E., Cho, H. R., Yoon, S., Yang, S., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b00651 · Cited by 239
Assessment of vascular wall shear stress and implications for atherosclerotic disease
Papaioannou, T. G., Karatzis, E. N., Vavuranakis, M., Lekakis, J. P., & Stefanadis, C. (2006) · International Journal of Cardiology · doi:10.1016/j.ijcard.2006.03.035 · Cited by 126
Metadata
- Authors
- LaDisa, J. F., Olson, L. E., Molthen, R. C., Hettrick, D. A., Pratt, P. F., Hardel, M. D., Kersten, J. R., Warltier, D. C., & Pagel, P. S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-05
- Volume
- 288
- Issue
- 5
- Pages
- H2465-H2475
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2041119324
- Cited by
- 185
- References
- 41
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.