Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 205

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Synergism of coupled subsarcolemmal Ca2+clocks and sarcolemmal voltage clocks confers robust and flexible pacemaker function in a novel pacemaker cell model

Open access
Maltsev, Victor A., Lakatta, Edward G. · 2009 · American Journal of Physiology-Heart and Circulatory Physiology

Abstract

Recent experimental studies have demonstrated that sinoatrial node cells (SANC) generate spontaneous, rhythmic, local subsarcolemmal Ca 2+releases (Ca 2+clock), which occur during late diastolic depolarization (DD) and interact with the classic sarcolemmal voltage oscillator (membrane clock) by activating Na+-Ca 2+exchanger current ( I NCX). This and other interactions between clocks, however, are not captured by existing essentially membrane-delimited cardiac pacemaker cell numerical models. Using wide-scale parametric analysis of classic formulations of membrane clock and Ca 2+cycling, we have constructed and initially explored a prototype rabbit SANC model featuring both clocks. Our coupled oscillator system exhibits greater robustness and flexibility than membrane clock operating alone. Rhythmic spontaneous Ca 2+releases of sarcoplasmic reticulum (SR)-based Ca 2+clock ignite rhythmic action potentials via late DD I NCX over much broader ranges of membrane clock parameters [e.g., L-type Ca 2+current ( I CaL) and/or hyperpolarization-activated (“funny”) current ( I f) conductances]. The system Ca 2+clock includes SR and sarcolemmal Ca 2+fluxes, which optimize cell Ca 2+balance to increase amplitudes of both SR Ca 2+release and late DD I NCX as SR Ca 2+pumping rate increases, resulting in a broad pacemaker rate modulation (1.8–4.6 Hz). In contrast, the rate modulation range via membrane clock parameters is substantially smaller when Ca 2+clock is unchanged or lacking. When Ca 2+clock is disabled, the system parametric space for fail-safe SANC operation considerably shrinks: without rhythmic late DD I NCX ignition signals membrane clock substantially slows, becomes dysrhythmic, or halts. In conclusion, the Ca 2+clock is a new critical dimension in SANC function. A synergism of the coupled function of Ca 2+and membrane clocks confers fail-safe SANC operation at greatly varying rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.01118.2008

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 205

Metadata

Authors
Maltsev, V. A., & Lakatta, E. G.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2009-03
Volume
296
Issue
3
Pages
H594-H615
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W1964799458
Cited by
205
References
2
FWCI
11.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Synergism of coupled subsarcolemmal Ca2+clocks and sarcolemmal voltage clocks confers robust and flexible pacemaker function in a novel pacemaker cell model. https://app.cochat.ai/papers/10.1152/ajpheart.01118.2008
The paper
Maltsev, V. A., & Lakatta, E. G. (2009). Synergism of coupled subsarcolemmal Ca2+clocks and sarcolemmal voltage clocks confers robust and flexible pacemaker function in a novel pacemaker cell model. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.01118.2008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.