Exercise reduces arterial pressure augmentation through vasodilation of muscular arteries in humans
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Exercise markedly influences pulse wave morphology, but the mechanism is unknown. We investigated whether effects of exercise on the arterial pulse result from alterations in stroke volume or pulse wave velocity (PWV)/large artery stiffness or reduction of pressure wave reflection. Healthy subjects ( n = 25) performed bicycle ergometry. with workload increasing from 25 to 150 W for 12 min. Digital arterial pressure waveforms were recorded using a servo-controlled finger cuff. Radial arterial pressure waveforms and carotid-femoral PWV were determined by applanation tonometry. Stroke volume was measured by echocardiography, and brachial and femoral artery blood flows and diameters were measured by ultrasound. Digital waveforms were recorded continuously. Other measurements were made before and after exercise. Exercise markedly reduced late systolic and diastolic augmentation of the peripheral pressure pulse. At 15 min into recovery, stroke volume and PWV were similar to baseline values, but changes in pulse wave morphology persisted. Late systolic augmentation index (radial pulse) was reduced from 54 ± 3.9% at baseline to 42 ± 3.7% ( P < 0.01), and diastolic augmentation index (radial pulse) was reduced from 37 ± 1.8% to 25 ± 2.9% ( P < 0.001). These changes were accompanied by an increase in femoral blood flow (from 409 ± 44 to 773 ± 48 ml/min, P < 0.05) and an increase in femoral artery diameter (from 8.2 ± 0.4 to 8.6 ± 0.4 mm, P < 0.05). In conclusion, exercise dilates muscular arteries and reduces arterial pressure augmentation, an effect that will enhance ventricular-vascular coupling and reduce load on the left ventricle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endothelial Function and Dysfunction: Testing and Clinical Relevance
Deanfield, J. E., Halcox, J. P., & Rabelink, T. J. (2007) · Circulation · doi:10.1161/circulationaha.106.652859 · Cited by 2,710
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Joannides, R., Haefeli, W. E., Linder, L., Richard, V., Bakkali, E. H., Thuillez, C., & Lüscher, T. F. (1995) · Circulation · doi:10.1161/01.cir.91.5.1314 · Cited by 1,622
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
The influence of heart rate on augmentation index and central arterial pressure in humans
Wilkinson, I. B., MacCallum, H., Flint, L., Cockcroft, J. R., Newby, D. E., & Webb, D. J. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00263.x · Cited by 1,091
Brunner, H., Cockcroft, J. R., Deanfield, J., Donald, A., Ferrannini, E., Halcox, J., Kiowski, W., L??scher, T. F., Mancia, G., Natali, A., et al. (2005) · Journal of Hypertension · doi:10.1097/00004872-200502000-00001 · Cited by 753
The Effects of Nitroglycerin and Amyl Nitrite on Arteriolar and Venous Tone in the Human Forearm
MASON, D. T., BRAUNWALD, E., Bullock, F. A., & King, C. V. (1965) · Circulation · doi:10.1161/01.cir.32.5.755 · Cited by 426
KROEKER, E. J., & WOOD, E. H. (1955) · Circulation Research · doi:10.1161/01.res.3.6.623 · Cited by 423
Insulin Causes Endothelial Dysfunction in Humans: Sites and Mechanisms
Arcaro, G., Cretti, A., Balzano, S., Lechi, A., Muggeo, M., Bonora, E., & Bonadonna, R. C. (2002) · Circulation · doi:10.1161/hc0502.103333 · Cited by 407
Endothelium-Derived Nitric Oxide Regulates Arterial Elasticity in Human Arteries In Vivo
Kinlay, S., Creager, M. A., Fukumoto, M., Hikita, H., Fang, J. C., Selwyn, A. P., & Ganz, P. (2001) · Hypertension · doi:10.1161/hy1101.095329 · Cited by 385
Cited by
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Park, J., Kim, M., Lee, Y., Lee, H. S., & Ko, H. (2015) · Science Advances · doi:10.1126/sciadv.1500661 · Cited by 939
Self‐Powered Real‐Time Arterial Pulse Monitoring Using Ultrathin Epidermal Piezoelectric Sensors
Park, D. Y., Joe, D. J., Kim, D. H., Park, H., Han, J. H., Jeong, C. K., Park, H., Park, J. G., Joung, B., & Lee, K. J. (2017) · Advanced Materials · doi:10.1002/adma.201702308 · Cited by 691
Lou, Z., Chen, S., Wang, L., Jiang, K., & Shen, G. (2016) · Nano Energy · doi:10.1016/j.nanoen.2016.02.053 · Cited by 533
Wang, Z., Chen, J., Cong, Y., Zhang, H., Xu, T., Nie, L., & Fu, J. (2018) · Chemistry of Materials · doi:10.1021/acs.chemmater.8b03999 · Cited by 396
A fully integrated wearable ultrasound system to monitor deep tissues in moving subjects
Lin, M., Zhang, Z., Gao, X., Bian, Y., Wu, R. S., Park, G., Lou, Z., Zhang, Z., Xu, X., Chen, X., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-01800-0 · Cited by 364
Piezoelectric energy harvesters for biomedical applications
Ali, F., Raza, W., Li, X., Gul, H., & Kim, K.-H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.01.012 · Cited by 300
Li, T., Qu, M., Carlos, C., Gu, L., Jin, F., Yuan, T., Wu, X., Xiao, J., Wang, T., Dong, W., et al. (2021) · Advanced Materials · doi:10.1002/adma.202006093 · Cited by 279
Liu, W., Liu, N., Yue, Y., Rao, J., Cheng, F., Su, J., Liu, Z., & Gao, Y. (2018) · Small · doi:10.1002/smll.201704149 · Cited by 255
Huang, Y.-C., Liu, Y., Ma, C., Cheng, H.-C., He, Q., Wu, H., Wang, C., Lin, C.-Y., Huang, Y., & Duan, X. (2020) · Nature Electronics · doi:10.1038/s41928-019-0356-5 · Cited by 233
Nanogenerator for Biomedical Applications
Feng, H., Zhao, C., Tan, P., Liu, R., Chen, X., & Li, Z. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701298 · Cited by 189
High-performance, flexible electronic skin sensor incorporating natural microcapsule actuators
Wang, L., Jackman, J. A., Tan, E.-L., Park, J. H., Potroz, M. G., Hwang, E. T., & Cho, N.-J. (2017) · Nano Energy · doi:10.1016/j.nanoen.2017.04.015 · Cited by 188
Stretchable and Highly Sensitive Optical Strain Sensors for Human-Activity Monitoring and Healthcare
Guo, J., Zhou, B., Zong, R., Pan, L., Li, X., Yu, X., Yang, C., Kong, L., & Dai, Q. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b09815 · Cited by 170
Masked hypertension is “unmasked” by low-intensity exercise blood pressure
Schultz, M. G., Hare, J. L., Marwick, T. H., Stowasser, M., & Sharman, J. E. (2011) · Blood Pressure · doi:10.3109/08037051.2011.566251 · Cited by 104
“Thus, exercise BP and vasodilatation of the muscular arteries supplying the skeletal muscle during exercise (29) could be arbitrated by other unknown factors.”
BackgroundCaffeine ingestion alters central hemodynamics following aerobic exercise in middle-aged men
Harber, M. P., McCurry, A., Carlini, N., Kistler, B., & Fleenor, B. S. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04521-3 · Cited by 11
Metadata
- Authors
- Munir, S., Jiang, B., Guilcher, A., Brett, S., Redwood, S., Marber, M., & Chowienczyk, P.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2008-04
- Volume
- 294
- Issue
- 4
- Pages
- H1645-H1650
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2060091699
- Cited by
- 175
- References
- 36
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.