Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 445

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Continuous measurement of tissue blood flow by laser-Doppler spectroscopy

Stern, M. D., Lappe, D. L., Bowen, P. D., Chimosky, J. E., Holloway, G. A., Keiser, H. R., Bowman, R. L.·1977·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

Laser light scattered from tissue in vivo is broadened in line width as a result of the Doppler shift produced by moving red cells in the microcirculation. A feasibility study was carried out to demonstrate use of this effect to measure and monitor tissue blood flow. Light from a helium-neon laser illuminated a 1-mm area of tissue (human skin or rat renal cortex), and the backscattered light was detected with a photomultiplier. The spectrum of the Doppler beat notes was analyzed directly with a digital spectrum analyzer, or processed by analog circuitry to yield a flow parameter based on the root-mean-square Doppler line width. This parameter was compared with 133Xe washout in the skin of volunteers subjected to UV-induced erythema and the skin of volunteers subjected to UV-induced erythema and was found to vary in an approximately linear manner with skin blood flow. The laser instrument provided continuous monitoring of blood flow fluctuations, including the pulsatile component. The instrument was used to monitor flow in the outer cortex of the rat kidney during administration of norepinephrine, angiotensin, hydralazine, dextran, dopamine, nitroprusside, and angiotensin blocked by saralasin. Dynamic and steady-state responses were consistent with known pharmacology and renal physiology, and with the assumption that vasoconstrictor angiotensin II receptors in the kidney are accessible to blood-borne inhibitors. The laser-Doppler method is a promising tool for rapid monitoring of dynamic changes in tissue perfusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1977.232.4.h441

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 445

Metadata

Authors
Stern, M. D., Lappe, D. L., Bowen, P. D., Chimosky, J. E., Holloway, G. A., Keiser, H. R., & Bowman, R. L.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1977-04-01
Volume
232
Issue
4
Pages
H441-H448
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2203999213
Cited by
445
References
7
FWCI
2.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous measurement of tissue blood flow by laser-Doppler spectroscopy. https://app.cochat.ai/papers/10.1152/ajpheart.1977.232.4.h441
The paper
Stern, M. D., Lappe, D. L., Bowen, P. D., Chimosky, J. E., Holloway, G. A., Keiser, H. R., & Bowman, R. L. (1977). Continuous measurement of tissue blood flow by laser-Doppler spectroscopy. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1977.232.4.h441

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.