A microscope-television system for studying flow velocity in human skin capillaries
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A noninvasive technique for studying blood flow dynamics in human skin capillaries is described. A light microscope combined with a closed-circuit TV system was used to monitor and record capillary blood flow velocity on video tape. Arterial pulsations were recorded plethysmographically and converted into video signals by modulating the position of a square, white area in the televised scene. Twelve healthy subjects were studied. The mean (+/- SD) resting capillary blood flow velocity was 0.65 +/- 0.3 mm/s at an average skin temperature of 30.4 +/- 2.3 degrees C. Spontaneous fluctuations at a frequency of 6-10 cycles/min were observed in most subjects. A well-pronounced flow pulsatile component could be demonstrated in all capillaries studied. The technique can be used in clinical practice for studying the physiology and pathophysiology of cutaneous microcirculation in man. It can be expected that the method may become an important diagnostic tool in diseases that involve disturbances of the microcirculation, such as diabetes, hypertension, and atherosclerosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A quantitative study of the hemodynamics in the living microvascular system
Bloch, E. H. (1962) · American Journal of Anatomy · doi:10.1002/aja.1001100204 · Cited by 172
Cited by
Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow
Nilsson, G. E., Tenland, T., & Oberg, P. A. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326582 · Cited by 1,095
Goedhart, P. T., Khalilzada, M., Bezemer, R., Merza, J., & Ince, C. (2007) · Optics Express · doi:10.1364/oe.15.015101 · Cited by 531
Monitoring the microcirculation in the critically ill patient: current methods and future approaches
De Backer, D., Ospina-Tascon, G., Salgado, D., Favory, R., Creteur, J., & Vincent, J.-L. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-2005-3 · Cited by 426
Vasomotion: Mechanisms and Physiological Importance
Nilsson, H. (2003) · Molecular Interventions · doi:10.1124/mi.3.2.79 · Cited by 342
Sildenafil in the Treatment of Raynaud’s Phenomenon Resistant to Vasodilatory Therapy
Fries, R., Shariat, K., von Wilmowsky, H., & Böhm, M. (2005) · Circulation · doi:10.1161/circulationaha.104.523324 · Cited by 337
Noon, J. P., Walker, B. R., Webb, D. J., Shore, A. C., Holton, D. W., Edwards, H. V., & Watt, G. C. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119354 · Cited by 331
Vasomotion – what is currently thought?
Aalkjær, C., Boedtkjer, D., & Matchkov, V. (2011) · Acta Physiologica · doi:10.1111/j.1748-1716.2011.02320.x · Cited by 252
Comparison of OPS imaging and conventional capillary microscopy to study the human microcirculation
Mathura, K. R., Vollebregt, K. C., Boer, K., De Graaff, J. C., Ubbink, D. T., & Ince, C. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.74 · Cited by 195
“It is known that the RBCVr in capillaries shows spontaneous fluctuations with a frequency of 4–11 cycles/min (7, 8, 17).”
BackgroundCapillaroscopy and the measurement of capillary pressure
Shore, A. C. (2000) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2000.00278.x · Cited by 164
Metadata
- Authors
- Fagrell, B., Fronek, A., & Intaglietta, M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1977-08-01
- Volume
- 233
- Issue
- 2
- Pages
- H318-H321
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1227221502
- Cited by
- 185
- References
- 1
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.