Regional blood flow during digestion in the conscious dog
The DOI matches its Crossref record.
Abstract
Blood flows to the major organs of the resting conscious dog were measured prior to and 30 and 90 min after feeding using the radioactive microsphere technique. Mean systemic arterial pressure, heart rate, and arterial PO2, PCO2, and pH, as well as blood flow to the brain, heart, adrenals, skeletal muscle, hepatic artery, and gastric antrum were not significantly changed following the meal. Pancreatic and duodenal and jejunal blood flows increased at both 30 and 90 min, whereas ileal blood flow increased only at 90 min after feeding. Flow to the gastric body increased in only half of the fed animals, but it increased in all of the animals treated with histamine. In all cases where there was an increase in total wall flow the increase was confined to the mucosa-submucosal layer. Blood flow to the colon was unchanged except for a decrease in the distal colon at 30 min. Thus, the cardiovascular response to feeding appears to be limited to those organs and tissues actively involved in digestion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zheng, L., Kelly, C. J., & Colgan, S. P. (2015) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00191.2015 · Cited by 499
Regulation of intestinal blood flow
Matheson, P. J., Wilson, M. A., & Garrison, R. N. (2000) · Journal of Surgical Research · doi:10.1006/jsre.2000.5862 · Cited by 296
“In contrast to this finding, the placement of a liquid saline solution or the solid phase of a predigested meal alone did not produce hyperemia [7, 34].”
BackgroundResultDuplex ultrasound measurement of postprandial intestinal blood flow: Effect of meal composition
Moneta, G. L., Taylor, D. C., Helton, W. S., Mulholland, M. W., & Strandness, D. E. (1988) · Gastroenterology · doi:10.1016/0016-5085(88)90364-2 · Cited by 277
Stomach-brain synchrony reveals a novel, delayed-connectivity resting-state network in humans
Rebollo, I., Devauchelle, A.-D., Béranger, B., & Tallon-Baudry, C. (2018) · eLife · doi:10.7554/elife.33321 · Cited by 194
“, 2000), but cerebral blood flow is unaltered (Gallavan et al., 1980).”
BackgroundChronic mesenteric ischemia: Clinical practice guidelines from the Society for Vascular Surgery
Huber, T. S., Björck, M., Chandra, A., Clouse, W. D., Dalsing, M. C., Oderich, G. S., Smeds, M. R., & Murad, M. H. (2021) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2020.10.029 · Cited by 152
Metadata
- Authors
- Gallavan, R. H., Chou, C. C., Kvietys, P. R., & Sit, S. P.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1980-02-01
- Volume
- 238
- Issue
- 2
- Pages
- H220-H225
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2119716061
- Cited by
- 103
- References
- 0
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regional blood flow during digestion in the conscious dog. https://app.cochat.ai/papers/10.1152/ajpheart.1980.238.2.h220
- The paper
- Gallavan, R. H., Chou, C. C., Kvietys, P. R., & Sit, S. P. (1980). Regional blood flow during digestion in the conscious dog. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1980.238.2.h220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.