Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record.

Reference sample microsphere method: cardiac output and blood flows in conscious rat

Ishise, Shozo, Pegram, Barbara L., Yamamoto, Jin, Kitamura, Yoshio, Frohlich, Edward D.·1980·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

Validation of the reference sample method (RSM) in the rat was accomplished by: 1) simultaneous measurement of cardiac output (CO) by the RSM and electromagnetic flowmetry method in ether-anesthetized open-chest Wistar rats, and 2) determination of systemic and regional hemodynamic reproducibility in conscious rats following three serial injections of microspheres. The optimal sampling time and sampling rate were determined in several CO states. The results indicate that: 1) 200 or more microspheres contained in the reference sample result in an accurate determination of CO, 2) almost 100% of the microspheres are trapped by tissues with in 20 s of cessation of the microsphere injection, 3) the hemodynamic steady state is affected only under low cardiac output conditions at a high sampling rate (1.211 ml/min), 4) three repeated injections of microspheres in conscious animals do not alter systemic hemodynamis, and 5) the reproducibility of regional blood flow distribution is good in all organs except the liver, stomach, spleen, and skin (third application). These data indicate that the RSM is reliable, providing reasonable accuracy and reproducibility of systemic and regional hemodynamics in the rat.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1980.239.4.h443

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Ishise, S., Pegram, B. L., Yamamoto, J., Kitamura, Y., & Frohlich, E. D.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1980-10-01
Volume
239
Issue
4
Pages
H443-H443
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2423810330
Cited by
230
References
0
FWCI
7.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reference sample microsphere method: cardiac output and blood flows in conscious rat. https://app.cochat.ai/papers/10.1152/ajpheart.1980.239.4.h443
The paper
Ishise, S., Pegram, B. L., Yamamoto, J., Kitamura, Y., & Frohlich, E. D. (1980). Reference sample microsphere method: cardiac output and blood flows in conscious rat. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1980.239.4.h443

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.