The DOI matches its Crossref record.
Reference sample microsphere method: cardiac output and blood flows in conscious rat
Abstract
Validation of the reference sample method (RSM) in the rat was accomplished by: 1) simultaneous measurement of cardiac output (CO) by the RSM and electromagnetic flowmetry method in ether-anesthetized open-chest Wistar rats, and 2) determination of systemic and regional hemodynamic reproducibility in conscious rats following three serial injections of microspheres. The optimal sampling time and sampling rate were determined in several CO states. The results indicate that: 1) 200 or more microspheres contained in the reference sample result in an accurate determination of CO, 2) almost 100% of the microspheres are trapped by tissues with in 20 s of cessation of the microsphere injection, 3) the hemodynamic steady state is affected only under low cardiac output conditions at a high sampling rate (1.211 ml/min), 4) three repeated injections of microspheres in conscious animals do not alter systemic hemodynamis, and 5) the reproducibility of regional blood flow distribution is good in all organs except the liver, stomach, spleen, and skin (third application). These data indicate that the RSM is reliable, providing reasonable accuracy and reproducibility of systemic and regional hemodynamics in the rat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vorobioff, J., Bredfeldt, J. E., & Groszmann, R. J. (1983) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1983.244.1.g52 · Cited by 432
McCullough, D. J., Stabley, J. N., Siemann, D. W., & Behnke, B. J. (2014) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/dju036 · Cited by 159
Metadata
- Authors
- Ishise, S., Pegram, B. L., Yamamoto, J., Kitamura, Y., & Frohlich, E. D.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1980-10-01
- Volume
- 239
- Issue
- 4
- Pages
- H443-H443
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2423810330
- Cited by
- 230
- References
- 0
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reference sample microsphere method: cardiac output and blood flows in conscious rat. https://app.cochat.ai/papers/10.1152/ajpheart.1980.239.4.h443
- The paper
- Ishise, S., Pegram, B. L., Yamamoto, J., Kitamura, Y., & Frohlich, E. D. (1980). Reference sample microsphere method: cardiac output and blood flows in conscious rat. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1980.239.4.h443
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.