Reference sample microsphere method: cardiac output and blood flows in conscious rat
The DOI matches its Crossref record.
Abstract
Validation of the reference sample method (RSM) in the rat was accomplished by: 1) simultaneous measurement of cardiac output (CO) by the RSM and electromagnetic flowmetry method in ether-anesthetized open-chest Wistar rats, and 2) determination of systemic and regional hemodynamic reproducibility in conscious rats following three serial injections of microspheres. The optimal sampling time and sampling rate were determined in several CO states. The results indicate that: 1) 200 or more microspheres contained in the reference sample result in an accurate determination of CO, 2) almost 100% of the microspheres are trapped by tissues with in 20 s of cessation of the microsphere injection, 3) the hemodynamic steady state is affected only under low cardiac output conditions at a high sampling rate (1.211 ml/min), 4) three repeated injections of microspheres in conscious animals do not alter systemic hemodynamis, and 5) the reproducibility of regional blood flow distribution is good in all organs except the liver, stomach, spleen, and skin (third application). These data indicate that the RSM is reliable, providing reasonable accuracy and reproducibility of systemic and regional hemodynamics in the rat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vorobioff, J., Bredfeldt, J. E., & Groszmann, R. J. (1983) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1983.244.1.g52 · Cited by 432
Stimulation by glucose of the blood flow to the pancreatic islets of the rat
Jansson, L., & Hellerstr�m, C. (1983) · Diabetologia · doi:10.1007/bf00251896 · Cited by 246
Dynamics of microvascular oxygen pressure across the rest-exercise transition in rat skeletal muscle
Behnke, B. J., Kindig, C. A., Musch, T. I., Koga, S., & Poole, D. C. (2001) · Respiration Physiology · doi:10.1016/s0034-5687(01)00195-5 · Cited by 187
Oxygen Exchange Profile in Rat Muscles of Contrasting Fibre Types
Behnke, B. J., McDonough, P., Padilla, D. J., Musch, T. I., & Poole, D. C. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.035915 · Cited by 181
“Total muscle blood flows and conductances to each tissue were calculated by the reference sample method (Ishise et al. 1980; Musch & Terrell, 1992) and expressed mass specifically in ml min_1 (100 g tissue)_1 and ml min_1 (100 g tissue)_1 mmHg_1, respectively.”
MethodKravetz, D., Sikuler, E., & Groszmann, R. J. (1986) · Gastroenterology · doi:10.1016/0016-5085(86)90390-2 · Cited by 177
Risk Mechanisms in Hypertensive Heart Disease
Frohlich, E. D. (1999) · Hypertension · doi:10.1161/01.hyp.34.4.782 · Cited by 176
Self-citationNovel Glucosensor for Hypoglycemic Detection Localized to the Portal Vein
Hevener, A. L., Bergman, R. N., & Donovan, C. M. (1997) · Diabetes · doi:10.2337/diab.46.9.1521 · Cited by 176
Exercise blood flow patterns within and among rat muscles after training
Armstrong, R. B., & Laughlin, M. H. (1984) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1984.246.1.h59 · Cited by 175
McCullough, D. J., Stabley, J. N., Siemann, D. W., & Behnke, B. J. (2014) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/dju036 · Cited by 159
“Total blood flow to each tissue was calculated by the reference sample method (22) and expressed in milliliters per minute per 100 g”
MethodPancreatic islet blood flow and its measurement
Jansson, L., Barbu, A., Bodin, B., Drott, C. J., Espes, D., Gao, X., Grapensparr, L., Källskog, Ö., Lau, J., Liljebäck, H., et al. (2016) · Upsala Journal of Medical Sciences · doi:10.3109/03009734.2016.1164769 · Cited by 159
“It was shown empirically in rats that this was the case when samples contained 200 microspheres (122).”
Background
Metadata
- Authors
- Ishise, S., Pegram, B. L., Yamamoto, J., Kitamura, Y., & Frohlich, E. D.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1980-10-01
- Volume
- 239
- Issue
- 4
- Pages
- H443-H443
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2423810330
- Cited by
- 230
- References
- 0
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.