The DOI matches its Crossref record.
Methods for isolation, cannulation, and in vitro study of single microvessels
Abstract
A method is described for the isolation and cannulation of microvessels (12-112 micrometers) that permits study, in vitro, of their physiology and pharmacology. Vessels from the hamster cheek pouch, testis, and mesentery and from rat brain have been isolated at 4 degrees C with specially prepared instruments and viewed with an inverted microscope. The vessels were cannulated at one end by equipment developed for renal tubular perfusion. The uncannulated end of the vessel is sealed, and experiments on reactivity and mechanics are carried out at fixed intravascular pressures. The isolated microvessels studied have a modulus of elasticity that is consistent with that observed in large vessels, and they display similar maximal active tension development (approximately 10(6) dyn/cm2). Reactivity to norepinephrine, acetylcholine, and adenosine are in the normal range for microvessels. Spontaneous tone is present, as evidenced by stable tonic contractions as well as phasic contractions in the frequency range of 3-30/min. The vessels display stress activation (myogenic response) consisting of contraction in response to increased intraluminal pressure. Our findings suggest that this preparation will be very useful in elucidating the physiology and pharmacology of the resistance vessels in the terminal vasculature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Signaling Mechanisms Underlying the Vascular Myogenic Response
Davis, M. J., & Hill, M. A. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.2.387 · Cited by 992
HÖGESTÄTT, E. D., ANDERSSON, K. ‐., & EDVINSSON, L. (1983) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1983.tb07178.x · Cited by 400
Segmental effects of norepinephrine and angiotensin II on isolated renal microvessels
Edwards, R. M. (1983) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.1983.244.5.f526 · Cited by 283
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Intrinsic increase in lymphangion muscle contractility in response to elevated afterload
Davis, M. J., Scallan, J. P., Wolpers, J. H., Muthuchamy, M., Gashev, A. A., & Zawieja, D. C. (2012) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01097.2011 · Cited by 133
Metadata
- Authors
- Duling, B. R., Gore, R. W., Dacey, R. G., & Damon, D. N.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1981-07-01
- Volume
- 241
- Issue
- 1
- Pages
- H108-H116
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2320450491
- Cited by
- 202
- References
- 0
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods for isolation, cannulation, and in vitro study of single microvessels. https://app.cochat.ai/papers/10.1152/ajpheart.1981.241.1.h108
- The paper
- Duling, B. R., Gore, R. W., Dacey, R. G., & Damon, D. N. (1981). Methods for isolation, cannulation, and in vitro study of single microvessels. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1981.241.1.h108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.