Direct measurement of microvessel hematocrit, red cell flux, velocity, and transit time
The DOI matches its Crossref record.
Abstract
A method is presented for the in vivo study of red cell flow dynamics. The method permits direct measurement of the red cell volume fraction in microvessel blood without resort to in vitro calibration curves. Furthermore, the method does not require extensive mathematical manipulation and can be applied to any microvascular network in any tissue. The method also enables direct measurement of red cell velocity, flux, and capillary transit time. Fluorescently labeled erythrocytes in tracer quantities, but known concentrations, are used as indicators of the behavior of the total cell population. Erythrocyte transit time across vascular networks and erythrocyte velocity are determined directly by following the behavior of the labeled cells. Hematocrit and red cell flux are measured by standard microcirculatory methods using labeled cells instead of the total cell population. Data are then converted to absolute values from the measured fraction of labeled cells. The method is thus absolutely dependent on the labeled cells being rheologically normal, and the conditions under which this requirement is satisfied are defined. Microvascular data obtained by the use of this method are presented for hamster cheek pouch and cremaster muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Biophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
Ye, T., Pan, D., Huang, C., & Liu, M. (2019) · Physics of Fluids · doi:10.1063/1.5068697 · Cited by 423
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Keller, M. W., Segal, S. S., Kaul, S., & Duling, B. (1989) · Circulation Research · doi:10.1161/01.res.65.2.458 · Cited by 267
Self-citationMicrovascular response to red blood cell transfusion in patients with severe sepsis*
Sakr, Y., Chierego, M., Piagnerelli, M., Verdant, C., Dubois, M.-J., Koch, M., Creteur, J., Gullo, A., Vincent, J.-L., & De Backer, D. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000269936.73788.32 · Cited by 248
“01), central venous pressure (from 10 [8–14] to 12 [10–16] mm Hg; p .”
Desjardins, C., & Duling, B. R. (1990) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1990.258.3.h647 · Cited by 221
Self-citationLong, D. S., Smith, M. L., Pries, A. R., Ley, K., & Damiano, E. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402937101 · Cited by 210
Skeletal muscle capillary hemodynamics from rest to contractions: implications for oxygen transfer
Kindig, C. A., Richardson, T. E., & Poole, D. C. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01222.2001 · Cited by 200
“Specifically, greater within-microcirculatory unit Hctcap uniformity would be expected if capillary Hctcap were under arteriolar control (20, 27, 33).”
BackgroundMyocardial density and composition: a basis for calculating intracellular metabolite concentrations
Vinnakota, K. C., & Bassingthwaighte, J. B. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00478.2003 · Cited by 175
“Because we included blood contained in the microvasculature (small arterioles, capillaries, and venules), we recognized that hematocrit decreases with vessel diameter (24, 29, 32) and attempted to account for reductions in hematocrit and density in small vessels and the microvascular network.”
MethodConducted Vascular Responses: Communication across the Capillary Bed
Collins, D. M., McCullough, W. T., & Ellsworth, M. L. (1998) · Microvascular Research · doi:10.1006/mvre.1998.2076 · Cited by 167
Embury, S. H. (2004) · Blood · doi:10.1182/blood-2004-02-0713 · Cited by 141
“2 mL sodium FITC to identify venules for study and to visualize bulk flow in the microcirculation, and we used the XRITC method described above to track the dynamic flow of RBC (Supplemental Movie #1).(20,31) During videotaping of the mucosal-intestinal microcirculation, we interchanged the fluorescein and XRITC filte…”
MethodInfluential
Metadata
- Authors
- Sarelius, I. H., & Duling, B. R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1982-12-01
- Volume
- 243
- Issue
- 6
- Pages
- H1018-H1026
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2172232302
- Cited by
- 224
- References
- 0
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.