Myogenic activity in isolated subepicardial and subendocardial coronary arterioles
The DOI matches its Crossref record.
Abstract
The goal of this study was to examine myogenic responses of isolated porcine subepicardial and subendocardial arterioles (80–100 micron in diameter) within physiological ranges of intraluminal pressure. Arterioles were located by perfusion with india ink-gelatin solution then dissected and cannulated with glass micropipettes. Intraluminal pressure was altered in 20-cmH2O steps over the range of 20–140 cmH2O. IN physiological salt solution (36–37 degrees C), the coronary arterioles developed spontaneous tone and exhibited myogenic responses. At the lower pressures (20–60 cmH2O), subendocardial arterioles responded passively (diameter decreased from a control diameter at 60 cmH2O), whereas subepicardial arterioles maintained their diameters. At higher pressures (100–140 cmH2O), both subepicardial and subendocardial arterioles demonstrated myogenic constriction, but subepicardial arterioles demonstrated greater myogenic constriction than subendocardial arterioles. This implies that myogenic autoregulation in subepicardial arterioles is better than that in the subendocardial arterioles at both low and high pressures. In the presence of nitroprusside (10(-4) M), all arterioles responded to pressure changes passively, and there were no differences between subepicardial and subendocardial vessels. The functional integrity of the endothelium was verified by relaxation to substance P (10(-7) M). This is the first in vitro study to demonstrate coronary myogenic activity and transmural differences in these arteriolar responses. Our data support the concept that myogenic mechanisms in 80 to 100-micron arterioles may actively contribute to autoregulation of coronary blood flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Signaling Mechanisms Underlying the Vascular Myogenic Response
Davis, M. J., & Hill, M. A. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.2.387 · Cited by 992
Self-citationIntravascular flow decreases erythrocyte consumption of nitric oxide
Liao, J. C., W. Hein, T., Vaughn, M. W., Huang, K.-T., & Kuo, L. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.15.8757 · Cited by 305
Self-citationRegulation of Cerebral Blood Flow
Peterson, E. C., Wang, Z., & Britz, G. (2011) · International Journal of Vascular Medicine · doi:10.1155/2011/823525 · Cited by 302
Regulation of Coronary Blood Flow
Goodwill, A. G., Dick, G. M., Kiel, A. M., & Tune, J. D. (2017) · Comprehensive Physiology · doi:10.1002/cphy.c160016 · Cited by 297
Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic duct
Gashev, A. A., Davis, M. J., & Zawieja, D. C. (2002) · The Journal of Physiology · doi:10.1113/jphysiol.2001.016642 · Cited by 282
Self-citationThe myogenic response: established facts and attractive hypotheses
SCHUBERT, R., & MULVANY, M. J. (1999) · Clinical Science · doi:10.1042/cs0960313 · Cited by 273
Cross-Talk Between Cardiac Muscle and Coronary Vasculature
Westerhof, N., Boer, C., Lamberts, R. R., & Sipkema, P. (2006) · Physiological Reviews · doi:10.1152/physrev.00029.2005 · Cited by 270
Kuo, L., Davis, M. J., & Chilian, W. M. (1995) · Circulation · doi:10.1161/01.cir.92.3.518 · Cited by 253
Self-citationTumor Necrosis Factor-α Induces Endothelial Dysfunction in Lepr db Mice
Gao, X., Belmadani, S., Picchi, A., Xu, X., Potter, B. J., Tewari-Singh, N., Capobianco, S., Chilian, W. M., & Zhang, C. (2007) · Circulation · doi:10.1161/circulationaha.106.650671 · Cited by 241
Self-citationKuo, L., Davis, M. J., Cannon, M. S., & Chilian, W. M. (1992) · Circulation Research · doi:10.1161/01.res.70.3.465 · Cited by 233
Self-citationZhang, C., Hein, T. W., Wang, W., Chang, C., & Kuo, L. (2001) · The FASEB Journal · doi:10.1096/fj.00-0681fje · Cited by 230
“The techniques for identifying and isolating pig coronary microvessels have been described in detail (14, 15).”
MethodSelf-citationCoronary Microcirculation in Health and Disease: Summary of an NHLBI Workshop
Chilian, W. M. (1997) · Circulation · doi:10.1161/01.cir.95.2.522 · Cited by 226
Self-citationPries, A. R., Badimon, L., Bugiardini, R., Camici, P. G., Dorobantu, M., Duncker, D. J., Escaned, J., Koller, A., Piek, J. J., & de Wit, C. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv100 · Cited by 224
Hein, T. W., & Kuo, L. (1999) · Circulation Research · doi:10.1161/01.res.85.7.634 · Cited by 202
Self-citationZhang, C., Hein, T. W., Wang, W., Miller, M. W., Fossum, T. W., McDonald, M. M., Humphrey, J. D., & Kuo, L. (2004) · Hypertension · doi:10.1161/01.hyp.0000146907.82869.f2 · Cited by 194
Self-citationJones, C. J. H., Kuo, L., Davis, M. J., DeFily, D. V., & Chilian, W. M. (1995) · Circulation · doi:10.1161/01.cir.91.6.1807 · Cited by 188
Self-citationHein, T. W., Zhang, C., Wang, W., Chang, C.-I., Thengchaisri, N., & Kuo, L. (2003) · The FASEB Journal · doi:10.1096/fj.03-0115fje · Cited by 182
“The techniques for identification and isolation of pig coronary microvessels were described in detail previously (22, 23).”
MethodSelf-citationGasheva, O. Y., Zawieja, D. C., & Gashev, A. A. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.115212 · Cited by 181
“…der Weid, 1998; Koller et al. 1999; Mizuno et al. 1999; Shirasawa et al. 2000; von der Weid et al. 2001; Gashev, 2002; Gashev et al. 2002, 2004) and other microcirculatory studies (Kuo et al. 1988, 1990a,b; Meininger et al. 1991; Hill & Gould, 1997; Hiramatsu et al. 1998; Guibert & Beech, 1999).”
BackgroundAGE/RAGE produces endothelial dysfunction in coronary arterioles in Type 2 diabetic mice
Gao, X., Zhang, H., Schmidt, A. M., & Zhang, C. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00464.2008 · Cited by 174
“Each coronary arteriole (40–100 m in internal diameter) was carefully isolated and then used in the functional and molecular studies described below (14).”
Histamine increases venular permeability via a phospholipase C-NO synthase-guanylate cyclase cascade
Yuan, Y., Granger, H. J., Zawieja, D. C., DeFily, D. V., & Chilian, W. M. (1993) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1993.264.5.h1734 · Cited by 173
Self-citationTNF-α Contributes to Endothelial Dysfunction in Ischemia/Reperfusion Injury
Zhang, C., Xu, X., Potter, B. J., Wang, W., Kuo, L., Michael, L., Bagby, G. J., & Chilian, W. M. (2006) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000201932.32678.7e · Cited by 171
Self-citationIshizaka, H., & Kuo, L. (1996) · Circulation Research · doi:10.1161/01.res.78.1.50 · Cited by 161
Self-citationHein, T. W., Belardinelli, L., & Kuo, L. (1999) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1016/s0022-3565(24)35152-3 · Cited by 159
“experiment using video microscopic techniques (Kuo et al., 1988).”
Self-citationLDLs Impair Vasomotor Function of the Coronary Microcirculation: Role of Superoxide Anions
Hein, T. W., & Kuo, L. (1998) · Circulation Research · doi:10.1161/01.res.83.4.404 · Cited by 116
Self-citationWang, W., Nepiyushchikh, Z., Zawieja, D. C., Chakraborty, S., Zawieja, S. D., Gashev, A. A., Davis, M. J., & Muthuchamy, M. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00312.2009 · Cited by 64
“This normalization procedure has been widely used in lymphatic studies (16, 17, 22, 27, 34, 46, 49) and other microcirculatory studies (20, 28, 32) to account for anatomic variations in vessel size.”
MethodSelf-citation
Metadata
- Authors
- Kuo, L., Davis, M. J., & Chilian, W. M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1988-12-01
- Volume
- 255
- Issue
- 6
- Pages
- H1558-H1562
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2276737872
- Cited by
- 218
- References
- 0
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.