Negative intrathoracic pressure decreases independently left ventricular filling and emptying
The DOI matches its Crossref record.
Abstract
The mechanism for the fall in left ventricular (LV) stroke volume with normal and obstructed inspiration is controversial with changes proposed in LV preload and afterload. During respiration extending over several cardiac cycles, changes in both LV filling and emptying could occur, rendering demonstration of any responsible mechanism difficult. To evaluate the independent effects of negative intrathoracic pressure (NITP) on LV filling and emptying, we have analyzed the effects of NITP confined to either diastole or systole using electrocardiogram (ECG)-triggered phrenic nerve stimulation in six anesthetized closed-chest dogs. Lung volume was either maintained by completely obstructing the airway or allowed to increase during NITP. With diastolic NITP and the airway obstructed during phrenic nerve stimulation, LV filling volume (integrated mitral flow) significantly decreased (-37 +/- 6.1% SE) associated with increases in LV and right atrial filling pressures at end diastole relative to both atmospheric and esophageal pressures. Right atrial pressure relative to either atmospheric or esophageal pressure increased significantly more than left atrial pressure. The ensuing LV stroke volume (integrated ascending aortic flow) decreased significantly (-30.8 +/- 5.9%). With NITP confined to systole and at constant LV preload, LV stroke volume also decreased (-12.9 +/- 2.5%) associated with an increase in LV systolic pressure relative to esophageal pressure. Similar significant changes were observed despite a smaller fall in esophageal pressure when lung volume was allowed to increase during either diastolic or systolic NITP. We conclude that 1) NITP confined to diastole decreases LV filling and the ensuing LV stroke volume, most likely by ventricular interdependence; 2) NITP confined to systole also decreases LV stroke volume, presumptively by imposing an increased afterload on the LV; 3) both diastolic and systolic mechanisms should contribute to a decreased LV stroke volume during normal and obstructed inspiration; and 4) if the effects of intrathoracic pressure changes were to extend over several cardiac cycles, mechanisms exist to account for either increases or decreases in LV volumes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Somers, V. K., White, D. P., Amin, R., Abraham, W. T., Costa, F., Culebras, A., Daniels, S., Floras, J. S., Hunt, C. E., Olson, L. J., et al. (2008) · Circulation · doi:10.1161/circulationaha.107.189420 · Cited by 1,297
Parati, G., Saul, J. P., Di Rienzo, M., & Mancia, G. (1995) · Hypertension · doi:10.1161/01.hyp.25.6.1276 · Cited by 849
Transfer function analysis of the circulation: unique insights into cardiovascular regulation
Saul, J. P., Berger, R. D., Albrecht, P., Stein, S. P., Chen, M. H., & Cohen, R. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.261.4.h1231 · Cited by 729
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661
Venous Function and Central Venous Pressure: A Physiologic Story
Gelman, S., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181672607 · Cited by 575
Sleep Apnea and Cardiovascular Disease: A Bidirectional Relationship
Kasai, T., Floras, J. S., & Bradley, T. D. (2012) · Circulation · doi:10.1161/circulationaha.111.070813 · Cited by 383
Cardiovascular effects of mechanical ventilation
Shekerdemian, L., & Bohn, D. (1999) · Archives of Disease in Childhood · doi:10.1136/adc.80.5.475 · Cited by 250
“Negative swings in intrathoracic pressure 16 17 —for example, during a Mueller manoeuvre (deep inspiration against a closed glottis), or the discontinuation of PPV, 18 can cause acute increases in afterload in the presence of poor LV function.”
BackgroundCardiorespiratory interactions in humans and animals: rhythms for life
Elstad, M., O’Callaghan, E. L., Smith, A. J., Ben-Tal, A., & Ramchandra, R. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00701.2017 · Cited by 170
“In addition to alterations in pressure from the right ventricle, there are a number of mechanisms including pulmonary transit time and afterload effect that have been proposed to account for the reduction in left ventricular filling and stroke volume during inspiration (53, 57, 81, 83), although not all of these mecha…”
Jolley, M., Colan, S. D., Rhodes, J., & DiNardo, J. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000717 · Cited by 163
Pulse rate variability is not a surrogate for heart rate variability
CONSTANT, I., LAUDE, D., MURAT, I., & ELGHOZI, J.-L. (1999) · Clinical Science · doi:10.1042/cs0970391 · Cited by 161
Pathophysiologic and therapeutic implicationsof sleep apnea in congestive heart failure
Bradley, T. D., & Floras, J. S. (1996) · Journal of Cardiac Failure · doi:10.1016/s1071-9164(96)80045-5 · Cited by 78
Metadata
- Authors
- Peters, J., Fraser, C., Stuart, R. S., Baumgartner, W., & Robotham, J. L.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1989-07-01
- Volume
- 257
- Issue
- 1
- Pages
- H120-H131
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1866542586
- Cited by
- 73
- References
- 0
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.