Regional vascular responses to prolonged lower body negative pressure in normal subjects
The DOI matches its Crossref record.
Abstract
The purpose of this study was to determine the effects of sustained unloading of baroreceptors in humans. The regional hemodynamic responses to lower body negative pressure (LBNP) were determined in 20 normal subjects. LBNP at -10 mmHg for 1 h decreased central venous pressure (CVP) without affecting blood pressure or heart rate, suggesting that only cardiopulmonary baroreceptors were unloaded. Forearm blood flow (FBF) and splanchnic blood flow (SBF) both decreased. Renal blood flow (RBF) did not change, but glomerular filtration rate (GFR) increased. Plasma renin activity rose slightly, whereas plasma norepinephrine levels did not change. Peak LBNP (either -20 or -40 mmHg for 1 h) caused a further decline in CVP and narrowed pulse pressure, thus unloading both arterial and cardiopulmonary baroreceptors. FBF returned to base-line values and SBF decreased further. RBF fell and the GFR remained increased. Plasma renin activity increased further, and plasma norepinephrine level rose. Thus the forearm and splanchnic circulations are sensitive to sustained unloading of cardiopulmonary baroreceptors; renal vasoconstriction occurs with additional unloading of arterial baroreceptors. Renin-angiotensin system activation during LBNP may be pertinent to the preservation of glomerular filtration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lower body negative pressure as a model to study progression to acute hemorrhagic shock in humans
Cooke, W. H., Ryan, K. L., & Convertino, V. A. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01155.2003 · Cited by 346
Dialysis hypotension: A hemodynamic analysis
Daugirdas, J. T. (1991) · Kidney International · doi:10.1038/ki.1991.28 · Cited by 334
van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Eckberg, D. L. (1991) · Clinical Science · doi:10.1042/cs0810575 · Cited by 323
Lower Body Negative Pressure: Physiological Effects, Applications, and Implementation
Goswami, N., Blaber, A. P., Hinghofer-Szalkay, H., & Convertino, V. A. (2019) · Physiological Reviews · doi:10.1152/physrev.00006.2018 · Cited by 217
Age, fitness, and regional blood flow during exercise in the heat
Ho, C. W., Beard, J. L., Farrell, P. A., Minson, C. T., & Kenney, W. L. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.4.1126 · Cited by 166
“Although some error is inherent in the use of this indicator technique with respect to the measurement of absolute organ flow, it has proven reliable in determining relative changes in flow from baseline within an individual (9).”
Metadata
- Authors
- Hirsch, A. T., Levenson, D. J., Cutler, S. S., Dzau, V. J., & Creager, M. A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1989-07-01
- Volume
- 257
- Issue
- 1
- Pages
- H219-H225
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2184499741
- Cited by
- 77
- References
- 0
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regional vascular responses to prolonged lower body negative pressure in normal subjects. https://app.cochat.ai/papers/10.1152/ajpheart.1989.257.1.h219
- The paper
- Hirsch, A. T., Levenson, D. J., Cutler, S. S., Dzau, V. J., & Creager, M. A. (1989). Regional vascular responses to prolonged lower body negative pressure in normal subjects. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1989.257.1.h219
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.