Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 343

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Heart rate and muscle sympathetic nerve variability during reflex changes of autonomic activity

Saul, J. P., Rea, R. F., Eckberg, D. L., Berger, R. D., Cohen, R. J.·1990·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

Low-frequency (less than 0.15 Hz) fluctuations of heart rate are increased by maneuvers, such as standing or hemorrhage, that increase sympathetic outflow to the heart and vasculature. To test the hypothesis that low-frequency heart rate fluctuations provide an index of sympathetic efferent activity, we compared power spectral measures of heart rate variability with two measures of sympathetic outflow, peroneal nerve sympathetic activity and antecubital vein plasma norepinephrine concentrations. Autonomic outflow was varied with graded stepwise infusions of nitroprusside and phenylephrine, which lowered or raised average diastolic pressures by approximately 15 mmHg. Before vasoactive drug infusions, no spectral measure of heart rate variability correlated significantly with muscle sympathetic activity, plasma norepinephrine concentration, average heart rate, or arterial pressure. During increases of muscle sympathetic activity and probable reductions of cardiac vagal activity induced by nitroprusside, the fraction of heart rate spectral power at low frequencies, but not the absolute value, correlated significantly with muscle sympathetic activity and plasma norepinephrine. However, during reductions of muscle sympathetic activity and probable elevations of cardiac vagal activity induced by phenylephrine, no measure of heart rate variability correlated significantly with muscle sympathetic activity. These findings can be explained by a model of heart rate control in which low-frequency heart rate fluctuations result from changing levels of both the sympathetic and parasympathetic inputs to the sinoatrial node.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1990.258.3.h713

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 343

Metadata

Authors
Saul, J. P., Rea, R. F., Eckberg, D. L., Berger, R. D., & Cohen, R. J.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1990-03-01
Volume
258
Issue
3
Pages
H713-H721
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2261584226
Cited by
343
References
2
FWCI
8.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart rate and muscle sympathetic nerve variability during reflex changes of autonomic activity. https://app.cochat.ai/papers/10.1152/ajpheart.1990.258.3.h713
The paper
Saul, J. P., Rea, R. F., Eckberg, D. L., Berger, R. D., & Cohen, R. J. (1990). Heart rate and muscle sympathetic nerve variability during reflex changes of autonomic activity. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1990.258.3.h713

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.