Arterioles supply oxygen to capillaries by diffusion as well as by convection
The DOI matches its Crossref record.
Abstract
In the early part of this century, August Krogh proposed a model of oxygen transport in capillaries that assumes that all oxygen is delivered to the capillaries by convection from small terminal arterioles and lost from these capillaries by diffusion. This model and its consequences have been used extensively to interpret whole organ oxygen transport data in terms of diffusion between capillaries and tissues and to relate changes in microvascular hemodynamics to alterations in oxygen transport. We evaluated the appropriateness of such extrapolation by measuring oxygen saturation at discrete locations along the lengths of individual capillaries in the hamster cheek pouch retractor muscle. Our results indicate that the amount of oxygen lost from individual capillaries can be markedly affected by the presence of larger microvessels that frequently cross the capillary path. These larger vessels act either as a diffusive supply of oxygen for the red blood cells within the capillary or as an additional sink for the oxygen depending on the direction of the oxygen tension gradient. This transfer of oxygen between larger microvessels and capillaries attenuates the importance of capillary hemodynamics in oxygen exchange. Therefore, conclusions about local oxygen exchange that utilize only hemodynamic data from whole organ or microvascular experiments and the Krogh model will generally be invalid and should be viewed with caution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oxygen Gradients in the Microcirculation
TSAI, A. G., JOHNSON, P. C., & INTAGLIETTA, M. (2003) · Physiological Reviews · doi:10.1152/physrev.00034.2002 · Cited by 450
Keeley, T. P., & Mann, G. E. (2019) · Physiological Reviews · doi:10.1152/physrev.00041.2017 · Cited by 329
Erythrocytes: Oxygen Sensors and Modulators of Vascular Tone
Ellsworth, M. L., Ellis, C. G., Goldman, D., Stephenson, A. H., Dietrich, H. H., & Sprague, R. S. (2009) · Physiology · doi:10.1152/physiol.00038.2008 · Cited by 321
Self-citationSimultaneous two-photon imaging of oxygen and blood flow in deep cerebral vessels
Lecoq, J., Parpaleix, A., Roussakis, E., Ducros, M., Houssen, Y. G., Vinogradov, S. A., & Charpak, S. (2011) · Nature Medicine · doi:10.1038/nm.2394 · Cited by 258
Regulation of Tissue Oxygenation
Pittman, R. N. (2011) · Colloquium Series on Integrated Systems Physiology: From Molecule to Function · doi:10.4199/c00029ed1v01y201103isp017 · Cited by 246
Self-citationMicrovascular and tissue oxygen gradients in the rat mesentery
Tsai, A. G., Friesenecker, B., Mazzoni, M. C., Kerger, H., Buerk, D. G., Johnson, P. C., & Intaglietta, M. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.12.6590 · Cited by 230
GOLDMAN, D., & POPEL, A. S. (2000) · Journal of Theoretical Biology · doi:10.1006/jtbi.2000.2113 · Cited by 203
Dewhirst, M. W., Ong, E. T., Braun, R. D., Smith, B., Klitzman, B., Evans, S. M., & Wilson, D. (1999) · British Journal of Cancer · doi:10.1038/sj.bjc.6690273 · Cited by 187
“…(Ells and Pittman, 1990; Kerger et al, 1995; Torres et al, 19 Longitudinal gradients also exist in normal tissues, but, becau the redundancy of vascular supply, such gradients do not le vascular or tissue hypoxia in most cases (Duling and Berne, 1 Ellsworth et al, 1987; Swain and Pittman, 1989).”
Sakadžić, S., Mandeville, E. T., Gagnon, L., Musacchia, J. J., Yaseen, M. A., Yucel, M. A., Lefebvre, J., Lesage, F., Dale, A. M., Eikermann-Haerter, K., et al. (2014) · Nature Communications · doi:10.1038/ncomms6734 · Cited by 183
“25,26 In addition, the large capacity of the microvascular network to increase SO 2 in high branching order capillaries during hyperemia in combination with dynamic shifting of the tissue supply territories and increase in fractional contribution of high branching order capillaries to oxygen…”
Red not dead: signaling in and from erythrocytes
Sprague, R. S., Stephenson, A. H., & Ellsworth, M. L. (2007) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2007.08.008 · Cited by 124
Self-citationRole of erythrocyte-released ATP in the regulation of microvascular oxygen supply in skeletal muscle
Ellsworth, M. L., Ellis, C. G., & Sprague, R. S. (2016) · Acta Physiologica · doi:10.1111/apha.12596 · Cited by 81
Self-citationLocal Regulation of Microvascular Perfusion
Davis, M. J., Hill, M. A., & Kuo, L. (2008) · Microcirculation · doi:10.1016/b978-0-12-374530-9.00006-1 · Cited by 78
Metadata
- Authors
- Ellsworth, M. L., & Pittman, R. N.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1990-04-01
- Volume
- 258
- Issue
- 4
- Pages
- H1240-H1243
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2115217870
- Cited by
- 127
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.