The DOI matches its Crossref record.
Interaction of pressure- and flow-induced responses in porcine coronary resistance vessels
Abstract
Pressure-induced myogenic responses and flow-induced vasodilatory responses have been documented in coronary resistance arterioles, but the interaction of these two mechanisms and the nature of the flow-mediated response are not well understood. Experiments were designed to quantitatively study the interaction of pressure- and flow-induced responses and to characterize the nature of the substance responsible for flow-mediated dilation in isolated coronary arterioles. Subepicardial arterioles (40-80 microns) were isolated from pigs and cannulated with two glass micropipettes and then pressurized via independent reservoir systems. Flow was initiated by simultaneously moving the reservoirs in equal and opposite directions thus generating a pressure gradient (delta P) without changing the mean intraluminal pressure (IP). IP was changed by moving both reservoirs in the same direction to alter myogenic tone in the absence of flow (delta P = 0). Flow-mediated dilation competed with myogenic constriction when flow and pressure were elevated. Also, flow potentiated myogenic dilation when IP was decreased. The magnitude of flow-induced dilation was greatest at an intermediate level of vascular tone (IP = 60 cmH2O) but was attenuated at higher and lower levels of tone. In the presence of flow (delta P = 4 cmH2O), pressure-diameter relationships were shifted upward, and the magnitude of myogenic responsiveness was attenuated. Double-vessel bioassay studies indicated that a transferable substance was released from intact endothelium in response to flow. Flow-induced dilation was not affected by indomethacin but was abolished by NG-monomethyl-L-arginine or by mechanical removal of endothelium.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Signaling Mechanisms Underlying the Vascular Myogenic Response
Davis, M. J., & Hill, M. A. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.2.387 · Cited by 992
Self-citationRegulation of coronary blood flow during exercise
Duncker, D. J., & Bache, R. J. (2008) · Physiological Reviews · doi:10.1152/physrev.00045.2006 · Cited by 936
Role for Hydrogen Peroxide in Flow-Induced Dilation of Human Coronary Arterioles
Miura, H., Bosnjak, J. J., Ning, G., Saito, T., Miura, M., & Gutterman, D. D. (2003) · Circulation Research · doi:10.1161/01.res.0000054200.44505.ab · Cited by 454
Koller, A., Sun, D., & Kaley, G. (1993) · Circulation Research · doi:10.1161/01.res.72.6.1276 · Cited by 329
Liu, Y., Zhao, H., Li, H., Kalyanaraman, B., Nicolosi, A. C., & Gutterman, D. D. (2003) · Circulation Research · doi:10.1161/01.res.0000091261.19387.ae · Cited by 323
Metadata
- Authors
- Kuo, L., Chilian, W. M., & Davis, M. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1991-12-01
- Volume
- 261
- Issue
- 6
- Pages
- H1706-H1715
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1846153624
- Cited by
- 389
- References
- 0
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interaction of pressure- and flow-induced responses in porcine coronary resistance vessels. https://app.cochat.ai/papers/10.1152/ajpheart.1991.261.6.h1706
- The paper
- Kuo, L., Chilian, W. M., & Davis, M. J. (1991). Interaction of pressure- and flow-induced responses in porcine coronary resistance vessels. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1991.261.6.h1706
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.