CoChat

Continuous assessment of hemodynamic control by complex demodulation of cardiovascular variability

Hayano, J., Taylor, J. A., Yamada, A., Mukai, S., Hori, R., Asakawa, T., Yokoyama, K., Watanabe, Y., Takata, K., Fujinami, T. · 1993 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 131

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Usefulness of complex demodulation (CDM) in assessing the frequency components of cardiovascular variability was assessed and, subsequently, this technique was utilized to determine the time-dependent responses of the low-frequency (LF) and high-frequency (HF) amplitudes of heart rate and blood pressure variabilities during postural tilt. CDM provides the time-dependent changes in amplitude of a particular frequency component on a continuous basis. Analysis of simulated data showed that CDM has sufficient frequency resolution to separately measure LF and HF amplitudes with a time resolution < 15 s and that CDM is robust to alterations in the frequency of the components. Analysis of actual data during postural tilt test in 23 young healthy subjects demonstrated that the HF amplitude of heart rate, an index of cardiac parasympathetic tone, rapidly decayed with head-up tilt (P < 0.01) and increased quickly showing an overshoot with tilt back to the supine position (P < 0.01). The LF amplitude of blood pressure, an index of vasomotor sympathetic activity, showed marked rhythmic fluctuation at an interval of 48-100 s during head-up tilt (P < 0.01), synchronizing with similar fluctuation in the LF amplitude of heart rate (P < 0.01). These results suggest that CDM can be used to provide a continuous assessment of cardiovascular variability components and that the dynamic responses of autonomic circulatory control to upright posture result in a phasic modulation of LF amplitude.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1993.264.4.h1229

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 131

Metadata

Authors
Hayano, J., Taylor, J. A., Yamada, A., Mukai, S., Hori, R., Asakawa, T., Yokoyama, K., Watanabe, Y., Takata, K., & Fujinami, T.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1993-04-01
Volume
264
Issue
4
Pages
H1229-H1238
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W1784971660
Cited by
131
References
6
FWCI
3.42
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Continuous assessment of hemodynamic control by complex demodulation of cardiovascular variability. https://app.cochat.ai/papers/10.1152/ajpheart.1993.264.4.h1229
The paper
Hayano, J., Taylor, J. A., Yamada, A., Mukai, S., Hori, R., Asakawa, T., Yokoyama, K., Watanabe, Y., Takata, K., & Fujinami, T. (1993). Continuous assessment of hemodynamic control by complex demodulation of cardiovascular variability. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1993.264.4.h1229

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.