Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
On the basis of the windkessel model, the stroke volume-to-aortic pulse pressure ratio (SV/PP) has been proposed as an estimate of total arterial compliance, but recent studies have questioned this approximation. Aortic pressure was obtained at rest in 31 adults undergoing cardiac catheterization (47 ± 14 yr): controls ( n = 7), patients with dilated cardiomyopathy ( n = 10), and patients with other cardiac diseases ( n = 14). We calculated PP, mean aortic pressure (MAoP), heart period ( T), SV (thermodilution cardiac output/heart rate), total peripheral resistance ( R), total arterial compliance estimated by area method ( C area), and the time constant of aortic pressure decay in diastole ( RC area). In the overall population ( n = 31), there was no significant difference between SV/PP and C area. SV/PP was linearly related to C area(SV/PP = 0.99 C area+ 0.05; r = 0.98; P < 0.001); the slope and intercept did not differ from unity and zero, respectively. Similar results were obtained in the three subgroups. These results implied that PP/MAoP and T/ RC area were proportionally related ( T/ RC area= 1.18PP/MAoP − 0.07; r = 0.96; P < 0.001). We conclude that for humans at rest 1) SV/PP gave a reliable estimate of C area, and 2) T normalized by the time constant of aortic pressure decay in diastole was proportionally related to PP/MAoP. This last relationship could be considered an aspect of the coupling between the left ventricle and its load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Aortic input impedance in normal man: relationship to pressure wave forms.
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980) · Circulation · doi:10.1161/01.cir.62.1.105 · Cited by 1,014
Darne, B., Girerd, X., Safar, M., Cambien, F., & Guize, L. (1989) · Hypertension · doi:10.1161/01.hyp.13.4.392 · Cited by 542
Elastic properties and Windkessel function of the human aorta
Belz, G. G. (1995) · Cardiovascular Drugs and Therapy · doi:10.1007/bf00877747 · Cited by 456
Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 454
Mechanical Principles in Arterial Disease
O’Rourke, M. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.2 · Cited by 401
Estimation of total arterial compliance: an improved method and evaluation of current methods
Liu, Z., Brin, K. P., & Yin, F. C. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.251.3.h588 · Cited by 378
Effects of age on ventricular-vascular coupling
Nichols, W. W., O'Rourke, M. F., Avolio, A. P., Yaginuma, T., Murgo, J. P., Pepine, C. J., & Conti, C. R. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90659-9 · Cited by 346
Evaluation of methods for estimation of total arterial compliance
Stergiopulos, N., Meister, J. J., & Westerhof, N. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.268.4.h1540 · Cited by 267
Effects of decreased aortic compliance on performance of the left ventricle
Urschel, C., Covell, J., Sonnenblick, E., Ross, J., & Braunwald, E. (1968) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1968.214.2.298 · Cited by 182
The Arterial System in Hypertension: A Prospective View
Safar, M. E., & Frohlich, E. D. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.10 · Cited by 160
An evaluation of large arteries compliance in man
Simon, A. C., Safar, M. E., Levenson, J. A., London, G. M., Levy, B. I., & Chau, N. P. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.5.h550 · Cited by 158
Systemic compliance: does it play a role in the genesis of essential hypertension?
Randall, O. S., van den Bos, G. C., Westerhof, N., & POT, F. O. M. (1984) · Cardiovascular Research · doi:10.1093/cvr/18.8.455 · Cited by 143
Aortic compliance in human hypertension.
Liu, Z. R., Ting, C.-T., Zhu, S., & Yin, F. C. P. (1989) · Hypertension · doi:10.1161/01.hyp.14.2.129 · Cited by 116
Remington, J. W., Noback, C. R., HAMILTON, W. F., & Gold, J. J. (1948) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1948.153.2.298 · Cited by 114
Matching between ventricle and arterial load. An evolutionary process.
Elzinga, G., & Westerhof, N. (1991) · Circulation Research · doi:10.1161/01.res.68.6.1495 · Cited by 101
Does obesity influence early target organ damage in hypertensive patients?
Schmieder, R. E., & Messerli, F. H. (1993) · Circulation · doi:10.1161/01.cir.87.5.1482 · Cited by 97
Impaired systemic arterial compliance in borderline hypertension
Ventura, H. O., Messerli, F. H., Oigman, W., Suarez, D. H., Dreslinski, G. R., Dunn, F. G., Reisin, E., & Frohlich, E. D. (1984) · American Heart Journal · doi:10.1016/0002-8703(84)90555-6 · Cited by 82
Marcus, R. H., Korcarz, C. E., McCray, G. R., Neumann, A., Murphy, M. F., Borow, K. M., Weinert, L., Bednarz, J., Gretler, D. D., & Spencer, K. T. (1994) · Circulation · doi:10.1161/01.cir.89.6.2688 · Cited by 81
Normalized input impedance and arterial decay time over heart period are independent of animal size
Westerhof, N., & Elzinga, G. (1991) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1991.261.1.r126 · Cited by 78
Merillon, J. P., Motté, G., Masquet, C., Azancot, I., Guiomard, A., & Gourgonf, R. (1982) · European Heart Journal · doi:10.1093/eurheartj/3.suppl_a.95 · Cited by 64
Chemla, D., Hébert, J., Coirault, C., Salmeron, S., Zamani, K., & Lecarpentier, Y. (1996) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1996.271.4.h1287 · Cited by 62
Self-citationRelation between aortic dicrotic notch pressure and mean aortic pressure in adults
Hébert, J., Lecarpentier, Y., Zamani, K., Coirault, C., Daccache, G., Chemla, D., Wuilliez, N., & Larsonneur, L. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80086-1 · Cited by 47
Self-citationArterial mechanical properties in dilated cardiomyopathy. Aging and the response to nitroprusside.
Carroll, J. D., Shroff, S., Wirth, P., Halsted, M., & Rajfer, S. I. (1991) · Journal of Clinical Investigation · doi:10.1172/jci115058 · Cited by 46
Arterial Compliance in Systolic Hypertension
Messerli, F. H., Ventura, H. O., Aristimuno, G. G., Suarez, D. H., Dreslinski, G. R., & Frohlich, E. D. (1982) · Clinical and Experimental Hypertension · doi:10.3109/10641968209060772 · Cited by 29
Effect of Arterial Compliance on Systolic Blood Pressure and Cardiac Function
Randall, O. S. (1982) · Clinical and Experimental Hypertension · doi:10.3109/10641968209060773 · Cited by 22
Aortic Rigidity and Plasma Catecholamines in Essential Hypertensive Patients
Alicandri, C. L., Agabiti‐Rosei, E., Fariello, R., Beschi, M., Boni, E., Castellano, M., Montini, E., Romanelli, G., Zaninelli, A., & Muiesan, G. (1982) · Clinical and Experimental Hypertension · doi:10.3109/10641968209060775 · Cited by 8
Cited by
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Passive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952
Pulse pressure—a review of mechanisms and clinical relevance
Dart, A. M., & Kingwell, B. A. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01108-1 · Cited by 836
“Arterial C can be estimated from the decay in diastolic pressure (2) as well as by the simpler approach of: C 5 stroke volume (SV)/PP, and studies have suggested reasonable correspondence between these meth-ods (3,4).”
MethodNoninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823
Metadata
- Authors
- Chemla, D., Hébert, J.-L., Coirault, C., Zamani, K., Suard, I., Colin, P., & Lecarpentier, Y.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1998-02-01
- Volume
- 274
- Issue
- 2
- Pages
- H500-H505
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2121513563
- Cited by
- 462
- References
- 28
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.