Total arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
On the basis of the windkessel model, the stroke volume-to-aortic pulse pressure ratio (SV/PP) has been proposed as an estimate of total arterial compliance, but recent studies have questioned this approximation. Aortic pressure was obtained at rest in 31 adults undergoing cardiac catheterization (47 ± 14 yr): controls ( n = 7), patients with dilated cardiomyopathy ( n = 10), and patients with other cardiac diseases ( n = 14). We calculated PP, mean aortic pressure (MAoP), heart period ( T), SV (thermodilution cardiac output/heart rate), total peripheral resistance ( R), total arterial compliance estimated by area method ( C area), and the time constant of aortic pressure decay in diastole ( RC area). In the overall population ( n = 31), there was no significant difference between SV/PP and C area. SV/PP was linearly related to C area(SV/PP = 0.99 C area+ 0.05; r = 0.98; P < 0.001); the slope and intercept did not differ from unity and zero, respectively. Similar results were obtained in the three subgroups. These results implied that PP/MAoP and T/ RC area were proportionally related ( T/ RC area= 1.18PP/MAoP − 0.07; r = 0.96; P < 0.001). We conclude that for humans at rest 1) SV/PP gave a reliable estimate of C area, and 2) T normalized by the time constant of aortic pressure decay in diastole was proportionally related to PP/MAoP. This last relationship could be considered an aspect of the coupling between the left ventricle and its load.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Aortic input impedance in normal man: relationship to pressure wave forms.
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980) · Circulation · doi:10.1161/01.cir.62.1.105 · Cited by 1,014
Darne, B., Girerd, X., Safar, M., Cambien, F., & Guize, L. (1989) · Hypertension · doi:10.1161/01.hyp.13.4.392 · Cited by 542
Elastic properties and Windkessel function of the human aorta
Belz, G. G. (1995) · Cardiovascular Drugs and Therapy · doi:10.1007/bf00877747 · Cited by 456
Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 454
Mechanical Principles in Arterial Disease
O’Rourke, M. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.2 · Cited by 401
Estimation of total arterial compliance: an improved method and evaluation of current methods
Liu, Z., Brin, K. P., & Yin, F. C. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.251.3.h588 · Cited by 378
Effects of age on ventricular-vascular coupling
Nichols, W. W., O'Rourke, M. F., Avolio, A. P., Yaginuma, T., Murgo, J. P., Pepine, C. J., & Conti, C. R. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90659-9 · Cited by 346
Evaluation of methods for estimation of total arterial compliance
Stergiopulos, N., Meister, J. J., & Westerhof, N. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.268.4.h1540 · Cited by 267
Cited by
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Passive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952
Pulse pressure—a review of mechanisms and clinical relevance
Dart, A. M., & Kingwell, B. A. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01108-1 · Cited by 836
“Arterial C can be estimated from the decay in diastolic pressure (2) as well as by the simpler approach of: C 5 stroke volume (SV)/PP, and studies have suggested reasonable correspondence between these meth-ods (3,4).”
MethodNoninvasive Assessment of Arterial Stiffness and Risk of Atherosclerotic Events
Oliver, J. J., & Webb, D. J. (2003) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000060460.52916.d6 · Cited by 823
Improved Arterial Compliance by a Novel Advanced Glycation End-Product Crosslink Breaker
Kass, D. A., Shapiro, E. P., Kawaguchi, M., Capriotti, A. R., Scuteri, A., deGroof, R. C., & Lakatta, E. G. (2001) · Circulation · doi:10.1161/hc3801.097806 · Cited by 727
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Vonk Noordegraaf, A., Chin, K. M., Haddad, F., Hassoun, P. M., Hemnes, A. R., Hopkins, S. R., Kawut, S. M., Langleben, D., Lumens, J., & Naeije, R. (2019) · European Respiratory Journal · doi:10.1183/13993003.01900-2018 · Cited by 569
Lam, C. S. P., Roger, V. L., Rodeheffer, R. J., Bursi, F., Borlaug, B. A., Ommen, S. R., Kass, D. A., & Redfield, M. M. (2007) · Circulation · doi:10.1161/circulationaha.106.659763 · Cited by 550
Briand, M., Dumesnil, J. G., Kadem, L., Tongue, A. G., Rieu, R., Garcia, D., & Pibarot, P. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.10.081 · Cited by 493
Melenovsky, V., Borlaug, B. A., Rosen, B., Hay, I., Ferruci, L., Morell, C. H., Lakatta, E. G., Najjar, S. S., & Kass, D. A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.08.050 · Cited by 485
Schram, M. T., Henry, R. M. A., van Dijk, R. A. J. M., Kostense, P. J., Dekker, J. M., Nijpels, G., Heine, R. J., Bouter, L. M., Westerhof, N., & Stehouwer, C. D. A. (2004) · Hypertension · doi:10.1161/01.hyp.0000111829.46090.92 · Cited by 428
Meng, K., Chen, J., Li, X., Wu, Y., Fan, W., Zhou, Z., He, Q., Wang, X., Fan, X., Zhang, Y., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201806388 · Cited by 409
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Arterial Stiffening With Exercise in Patients With Heart Failure and Preserved Ejection Fraction
Reddy, Y. N. V., Andersen, M. J., Obokata, M., Koepp, K. E., Kane, G. C., Melenovsky, V., Olson, T. P., & Borlaug, B. A. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.05.029 · Cited by 262
Charlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J. (2019) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2019 · Cited by 256
Sex-Specific Cardiovascular Structure and Function in Heart Failure with Preserved Ejection Fraction
Gori, M., Lam, C. S. P., Gupta, D. K., Santos, A. B. S., Cheng, S., Shah, A. M., Claggett, B., Zile, M. R., Kraigher-Krainer, E., Pieske, B., et al. (2014) · European Journal of Heart Failure · doi:10.1002/ejhf.67 · Cited by 241
Fujimoto, N., Prasad, A., Hastings, J. L., Arbab-Zadeh, A., Bhella, P. S., Shibata, S., Palmer, D., & Levine, B. D. (2010) · Circulation · doi:10.1161/circulationaha.110.973784 · Cited by 231
Predicting Fluid Responsiveness in Children: A Systematic Review
Gan, H., Cannesson, M., Chandler, J. R., & Ansermino, J. M. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182a9557e · Cited by 226
Wang, Z., & Chesler, N. C. (2011) · Pulmonary Circulation · doi:10.4103/2045-8932.83453 · Cited by 224
“such as pressure-strain modulus (Ep), 35] stiffness constant β,[36,37] distensibility (D)[23,38-41] and compliance (C),[23,38,42-44] or describe the material properties of the wall independent of geometry, such as elastic modulus (E)[34,45] and incremental elastic modulus (Einc).”
BackgroundThe Critical Role of Pulmonary Arterial Compliance in Pulmonary Hypertension
Thenappan, T., Prins, K. W., Pritzker, M. R., Scandurra, J., Volmers, K., & Weir, E. K. (2016) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201509-599fr · Cited by 223
Use of pulse pressure method for estimating total arterial compliance in vivo
Stergiopulos, N., Segers, P., & Westerhof, N. (1999) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1999.276.2.h424 · Cited by 211
Kizer, J. R., Arnett, D. K., Bella, J. N., Paranicas, M., Rao, D. C., Province, M. A., Oberman, A., Kitzman, D. W., Hopkins, P. N., Liu, J. E., et al. (2004) · Hypertension · doi:10.1161/01.hyp.0000128738.94190.9f · Cited by 209
Arterial Pulse Pressure Variation with Mechanical Ventilation
Teboul, J.-L., Monnet, X., Chemla, D., & Michard, F. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201801-0088ci · Cited by 200
“7 Aortic pulse pressure (systolic pressure minus diastolic pressure) is directly proportional to LV stroke volume and inversely related to aortic compliance (22).”
BackgroundSelf-citationHermans, M. M. H., Henry, R., Dekker, J. M., Kooman, J. P., Kostense, P. J., Nijpels, G., Heine, R. J., & Stehouwer, C. D. A. (2007) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006111217 · Cited by 196
“cording to the ratio of stroke volume to aortic PP (26).”
BackgroundMonge García, M. I., Gil Cano, A., & Gracia Romero, M. (2011) · Critical Care · doi:10.1186/cc9420 · Cited by 192
“Although this index has demonstrated underestimate the total arterial stiffness measured by others methods [20,21], since assumes that the total stroke volume is buffered in the elastic arteries during systole without any peripheral outflow, it has been proved to be useful for estimating and detecting changes in arter…”
Bonapace, S., Perseghin, G., Molon, G., Canali, G., Bertolini, L., Zoppini, G., Barbieri, E., & Targher, G. (2012) · Diabetes Care · doi:10.2337/dc11-1820 · Cited by 183
“Systemic arterial compliance was estimated by the stroke volume–to– pulse pressure ratio and systemic vascular resistance index by mean arterial pressure divided by cardiac index 380 (27).”
MethodImpact of systemic hypertension on the assessment of aortic stenosis
Kadem, L., Dumesnil, J. G., Rieu, R., Durand, L.-G., Garcia, D., & Pibarot, P. (2005) · Heart · doi:10.1136/hrt.2003.030601 · Cited by 170
Monnet, X., Bataille, A., Magalhaes, E., Barrois, J., Le Corre, M., Gosset, C., Guerin, L., Richard, C., & Teboul, J.-L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2693-y · Cited by 159
Wong, A. T. Y., Chan, D. C., Barrett, P. H. R., Adams, L. A., & Watts, G. F. (2013) · The Journal of Nutrition · doi:10.3945/jn.112.169359 · Cited by 23
Metadata
- Authors
- Chemla, D., Hébert, J.-L., Coirault, C., Zamani, K., Suard, I., Colin, P., & Lecarpentier, Y.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1998-02-01
- Volume
- 274
- Issue
- 2
- Pages
- H500-H505
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2121513563
- Cited by
- 462
- References
- 28
- FWCI
- 4.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.