Characterization of stretch-activated cation current in coronary smooth muscle cells
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Stretch-activated ion currents were recorded from vascular smooth muscle (VSM) after enzymatic isolation of single cells from porcine coronary arterioles. Patch pipettes were used to record whole cell current and control cell length. Under voltage clamp in physiological saline solution, an inward cation current ( I CAT) was activated by 105–135% longitudinal stretch. I CAT coincided with an increase in intracellular Ca 2+concentration. Under current clamp, membrane depolarization was induced by stretch. The magnitude of I CAT varied from −0.8 to −6.9 pA/pF at a holding potential of −60 mV. I CAT was graded with stretch, inactivated on release, and could be repeatedly induced. A potassium current ( I K) activated in unstretched cells by depolarization was also enhanced by stretch. In Ca 2+-free bath solution, stretch-induced enhancement of I K was blocked, but I CAT was still present. Hexamethyleneamiloride (50 μM), a reputed inhibitor of mechanosensitive channels, blocked I CAT and the stretch-induced increase in I K but not basal I K. Grammostolla spatulata venom (1:100,000) blocked basal I K, blocked stretch-induced increases in I K, and blocked I CAT. Iberiotoxin, a specific Ca 2+-activated K+channel blocker, did not alter I CAT but blocked the stretch-induced increase in I K and increased the magnitude of stretch-induced depolarization. We concluded that longitudinal stretch directly activates a cation current and secondarily activates a Ca 2+-activated K+current in isolated coronary myocytes. Although these two currents would partially counteract each other, the predominance of I CAT at physiological potentials is likely to explain the depolarization and contraction observed in intact coronary VSM during pressure elevation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myogenic responses of isolated arterioles: test for a rate-sensitive mechanism
Davis, M. J., & Sikes, P. J. (1990) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1990.259.6.h1890 · Cited by 87
Self-citation
Cited by
Renal Autoregulation in Health and Disease
Carlström, M., Wilcox, C. S., & Arendshorst, W. J. (2015) · Physiological Reviews · doi:10.1152/physrev.00042.2012 · Cited by 485
Potassium Channels in the Peripheral Microcirculation
JACKSON, W. F. (2005) · Microcirculation · doi:10.1080/10739680590896072 · Cited by 338
Smooth Muscle Ion Channels and Regulation of Vascular Tone in Resistance Arteries and Arterioles
Tykocki, N. R., Boerman, E. M., & Jackson, W. F. (2017) · Comprehensive Physiology · doi:10.1002/cphy.c160011 · Cited by 335
Regulation of Coronary Blood Flow
Goodwill, A. G., Dick, G. M., Kiel, A. M., & Tune, J. D. (2017) · Comprehensive Physiology · doi:10.1002/cphy.c160016 · Cited by 297
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Self-citation
Metadata
- Authors
- Wu, X., & Davis, M. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2001-04-01
- Volume
- 280
- Issue
- 4
- Pages
- H1751-H1761
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2162694593
- Cited by
- 87
- References
- 1
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of stretch-activated cation current in coronary smooth muscle cells. https://app.cochat.ai/papers/10.1152/ajpheart.2001.280.4.h1751
- The paper
- Wu, X., & Davis, M. J. (2001). Characterization of stretch-activated cation current in coronary smooth muscle cells. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.2001.280.4.h1751
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.