Endothelin type A receptor antagonist normalizes blood pressure in rats exposed to eucapnic intermittent hypoxia
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We have reported that eucapnic intermittent hypoxia (E-IH) causes systemic hypertension, elevates plasma endothelin 1 (ET-1) levels, and augments vascular reactivity to ET-1 and that a nonspecific ET-1 receptor antagonist acutely lowers blood pressure in E-IH-exposed rats. However, the effect of chronic ET-1 receptor inhibition has not been evaluated, and the ET receptor subtype mediating the vascular effects has not been established. We hypothesized that E-IH causes systemic hypertension through the increased ET-1 activation of vascular ET type A (ET A) receptors. We found that mean arterial pressure (MAP) increased after 14 days of 7 h/day E-IH exposure (109 ± 2 to 137 ± 4 mmHg; P < 0.005) but did not change in sham-exposed rats. The ET A receptor antagonist BQ-123 (10 to 1,000 nmol/kg iv) acutely decreased MAP dose dependently in conscious E-IH but not sham rats, and continuous infusion of BQ-123 (100 nmol·kg−1·day−1 sc for 14 days) prevented E-IH-induced increases in MAP. ET-1-induced constriction was augmented in small mesenteric arteries from rats exposed 14 days to E-IH compared with those from sham rats. Constriction was blocked by the ET A receptor antagonist BQ-123 (10 μM) but not by the ET type B (ET B) receptor antagonist BQ-788 (100 μM). ET A receptor mRNA content was greater in renal medulla and coronary arteries from E-IH rats. ET B receptor mRNA was not different in any tissues examined, whereas ET-1 mRNA was increased in the heart and in the renal medulla. Thus augmented ET-1-dependent vasoconstriction via vascular ET A receptors appears to elevate blood pressure in E-IH-exposed rats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
Obstructive sleep apnoea syndrome – an oxidative stress disorder
Lavie, L. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0261 · Cited by 993 · cited 1×
“In addition, E-IH increases oxidative stress (37), which in turn increases levels of transcription factors such as AP-1 and NF- B (37), which also stimulate ET-1 synthesis (18, 51).”
BackgroundHigh prevalence of unrecognized sleep apnoea in drug-resistant hypertension
Logan, A. G., Perlikowski, S. M., Mente, A., Tisler, A., Tkacova, R., Niroumand, M., Leung, R. S. T., & Bradley, T. D. (2001) · Journal of Hypertension · doi:10.1097/00004872-200112000-00022 · Cited by 960 · cited 1×
“Rather, the activation of multiple systems during this syndrome produces a hypertension that is resistant to most antihypertensive treatments aimed at a single system (39).”
BackgroundNewman, A. B. (2001) · American Journal of Epidemiology · doi:10.1093/aje/154.1.50 · Cited by 603
Bratel, T., Wennlund, A., & Carlström, K. (1999) · Respiratory Medicine · doi:10.1016/s0954-6111(99)90068-9 · Cited by 168
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
“More recently, investigators have used chronic intermittent hypoxia (CIH) paradigms that model “mild” (244) and “moderate” (9, 292, 315, 390, 686) levels of SDB.”
BackgroundRegulation of Blood Pressure and Salt Homeostasis by Endothelin
Kohan, D. E., Rossi, N. F., Inscho, E. W., & Pollock, D. M. (2011) · Physiological Reviews · doi:10.1152/physrev.00060.2009 · Cited by 433
Cerebrovascular Consequences of Obstructive Sleep Apnea
Durgan, D. J., & Bryan, R. M. (2012) · Journal of the American Heart Association · doi:10.1161/jaha.111.000091 · Cited by 197
The polymorphic and contradictory aspects of intermittent hypoxia
Almendros, I., Wang, Y., & Gozal, D. (2014) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00089.2014 · Cited by 174
Belaidi, E., Joyeux-Faure, M., Ribuot, C., Launois, S. H., Levy, P., & Godin-Ribuot, D. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.12.050 · Cited by 169
Metadata
- Authors
- Allahdadi, K. J., Cherng, T. W., Pai, H., Silva, A. Q., Walker, B. R., Nelin, L. D., & Kanagy, N. L.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2008-07
- Volume
- 295
- Issue
- 1
- Pages
- H434-H440
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2119945057
- Cited by
- 58
- References
- 5
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.